WEINTEK Ethernet Easy Tag
Specifications
- Product Name: Inovance Easy Tag (Ethernet)
- Supported Series: Inovance Easy Series
- Website: http://www.inovance.cn/
- PLC Connection Guide:
- HMI Settings:
- PLC type: Inovance Easy Tag (Ethernet)
- PLC I/F Port no.: 44818
- PLC Settings:
- [EtherNet/IP Adapter] -> Add connection
- After adding a connection channel and downloading it correctly
- To the PLC, the HMI can communicate with the PLC normally.
- HMI Settings:
Product Usage Instructions
PLC Connection Guide:
- Import Tags:
- Use AutoShop V4.2.0.0 software
- Variable -> Right click -> Export -> Save CSV File
- EasyBuilder Pro -> System Parameter Settings -> Tag Manager -> Import Tags (CSV)
- Ensure imported tag information is successful.
Support Device Type:
Data types supported include Bool, Byte, Int, DInt, Real, String, Array in EasyBuilder data format.
Wiring Diagram:
Ethernet cable: [Include wiring diagram here]
Inovance Easy Tag (Ethernet)
- Supported Series: Inovance Easy Series
- Website: http://www.inovance.cn/
HMI Settings:
Parameters | Recommended | Options | Notes |
PLC type | Inovance Easy Tag (Ethernet) | ||
PLC I/F | Ethernet | ||
Port no. | 44818 |
PLC Settings
[EtherNet/IP Adapter] -> Add connectionAfter adding a connection channel and downloading it correctly to the PLC, the HMI can communicate with the PLC normally.
- The following instructions use the software as: AutoShop V4.2.0.0 Variable -> Right click -> Export -> Save CSV File
- EasyBuilder Pro -> System Parameter Settings -> Tag Manager -> Import Tags (CSV)
- Imported tag information successfully.
Support Device Type
Data type | EasyBuilder data format | Memo |
Bool | Bit | |
Byte | 16-bit BCD, Hex, Binary, Signed | 8-bit |
Int | 16-bit BCD, Hex, Binary, Signed | 16-bit |
DInt | 16-bit BCD, Hex, Binary, Signed | 32-bit |
Real | 32-bit Float | 32-bit |
String | ASCII input and ASCII display | |
Array | Supports the above basic types |
Wiring Diagram
Ethernet cable:
FAQS
- Q: How do I troubleshoot communication issues between the HMI and PLC?
A: Check the Ethernet cable connections, ensure correct settings in the software, and verify proper PLC configuration. - Q: Can I use a different software version for importing tags?
A: It is recommended to use the specified software version mentioned in the instructions for seamless tag import.
Documents / Resources
![]() |
WEINTEK Ethernet Easy Tag [pdf] User Guide Ethernet, Ethernet Easy Tag, Ethernet Easy Tag, Easy Tag, Tag |