WACHENDORFF Box-PC Instruction Manual

WACHENDORFF-logo

WACHENDORFF Box-PC

WACHENDORFF-Box-PC-product

Overview

Follow the installation instructions to ensure long service life: verify connections, comply with local electrical standards, mount the fanless PC for proper convection cooling, and connect power using either the DC screw terminal or the DC barrel-socket option (only one at a time).

Specifications & Key Product Characteristics

Item Specification
Power supply SELV-compliant DC: 12 to 36 VDC (direct current only)
Peak inrush current Up to 4 A
Fuse (minimum) 1.6 A / 250 V, replace only by qualified personnel; use exclusively in the DC circuit
Cooling Fanless; passive heat dissipation via housing surface (convection)
Clearance for air circulation At least 3 cm around the unit
Relative humidity 10% to 90% (non-condensing)
IP protection IP30; IP2X on the sides
Electrical environment / CE Complies with European CE requirements; correct cable routing and proper earthing required for proper operation
Allowed installation environment Do not use in explosion risk areas; avoid locations with corrosive gases (e.g., SO2); avoid mechanical vibrations/impacts
Power connection options (1) Screw terminal: direct connection of 12–36 VDC (2) DC barrel socket (5.5 × 2.5 mm): 12–36 VDC via external power supply (accessory, not included)
Included accessories (in packaging) 1× connector plug, 2× mounting brackets, 4× screws

Interfaces vary by processor generation. Available base counts include Ethernet (2× RJ-45 Gigabit, electrically isolated), Wi‑Fi (1× IEEE 802.11 a/b/g/n), Bluetooth (1×), HDMI (1×) and VGA (1×), and audio (1× 3.5 mm Audio In/Out). USB and serial counts differ by model; see Quick Guide/Interfaces section as needed.

Quick Setup & Use (Installation)

  1. Plan placement: Install on a level wall, mounting plate inside a control cabinet, or desktop surface using the integrated mounting brackets. Ensure cooling fins are aligned vertically.
  2. Provide airflow: Maintain at least 3 cm clearance around the unit for convection cooling.
  3. Mount safely: Avoid direct vibration. Route all connection cables with strain relief.
  4. Check packaging contents: Confirm the box includes: 1× connector plug, 2× mounting brackets, 4× screws, plus the Box PC.
  5. Connect power (choose one option):
    • Screw terminal: Connect DC power supply + to DC+ and – to DC- (GND).
    • Or DC barrel socket (5.5 × 2.5 mm): Supply 12–36 VDC via an external power supply unit (accessory, not included).
  6. Do not mix power options: Use only one of the two power sockets at a time.
  7. Earth/avoid multiple earth potentials: Never connect the Box PC to multiple devices with different earth potentials to avoid potential differences that could damage USB or communication interfaces.

Foreword

Thank you for choosing a Wachendorff product. To ensure the appliance has a long service life, please check and compare all the appliance’s connections with this manual before switching it on.

Warranty Terms

Defective devices are either repaired or replaced. However, this does not apply to the following points:

  • The device is more than 3 years old from the date of purchase.
  • Damage has been caused by the use of force.
  • Repairs have not been carried out by us.
  • There is software damage and its consequences.

Warning

Ensure that all local and national electrical standards are complied with when installing the appliance.

Safety Instructions

  • Power supply: Use a supply voltage that complies with SELV (Safety Extra-Low Voltage) requirements. The device can only be operated with direct current, voltage range: 12 to 36 VDC. The peak inrush current can be up to 4 A.
  • Fuse: Minimum rated value of the fuse: 1.6 A/250 V. Use the fuse exclusively in the DC circuit. The fuse must only be replaced by qualified personnel.
  • Overvoltage: DC power sources must ensure isolation from the mains supply and similar hazards.
  • EMERGENCY STOP: A hard-wired EMERGENCY STOP must be present in every system to meet ICS safety requirements.

Cabling

  1. The length of power cables should be kept as short as possible.
  2. Use twisted-Pair cables for power and signal lines and ensure impedance matching.
  3. If the cabling is exposed to lightning strikes or power surges, suitable surge protection devices must be used.
  4. Keep AC, high-energy and fast-switching DC cables separate from signal cables.
  5. Connect a resistor and a capacitor in parallel between the un-earthed DC power supply and the chassis earth.

This creates a discharge path for static electricity and high-frequency power dissipation. Typical values are 1 MΩ and 4,700 pF.Please note that the equipment may fail due to an internal fault, which could cause it to enter an unsafe state.

Wachendorff logo

Furthermore, electrical faults in the user interface may lead to the connected equipment starting up unintentionally. This may result in damage to property and/or injury to the operator. If you have programmable logic controllers (PLCs) that require operator intervention, be aware of the safety risks and take appropriate precautions.

Category Specification / Guideline
Electrical Environment The BPC unit complies with European CE requirements. This means that the unit’s electronics are protected against external electrical influences. However, in certain circumstances, there is no complete protection. Correct cable routing and proper earthing ensure the unit operates correctly.
Environmental Conditions
  • Ensure that the device has been installed correctly and that the device specifications have been adhered to. Avoid installing the devices in locations where mechanical vibrations or impacts occur.
  • Do not operate the device in locations where there is a risk of explosion, e.g. due to flammable gases, vapours or dust.
  • Do not install the device in locations where corrosive gases such as SO2 are present.
  • Relative humidity: 10% to 90% (non-condensing)
IP-protection rating IP30, IP2X on the sides

Important Information

Once you have opened the packaging, please check that, in addition to the Box PC, the following accessories are included in the box:

  • 1x connector plug
  • 2x mounting brackets
  • 4x screws

Assembly Instructions

The WACHENDORFF BASIC Box PC is, as standard, screwed flat onto a level wall, a mounting plate inside a control cabinet or onto a desktop surface using the integrated mounting brackets. Please refer to the data sheet for the mounting dimensions. As the device operates entirely without a fan, heat dissipation takes place passively via the surface of the housing. When installing the unit, it is essential to ensure that the cooling fins are aligned vertically and that there is a clearance of at least 3 cm around the unit to ensure adequate air circulation (convection). Protect the PC from direct vibration and ensure that all connection cables are routed with strain relief.

Technical mounting diagram showing bracket positions and alignment axes.

Power Connection

The Box PC has two options for connecting the power supply:

  • Screw terminal (see section 7.1/7.2): For direct connection of a DC voltage of 12 VDC to 36 VDC.
  • DC socket (5.5 x 2.5 mm barrel plug): For supplying 12 VDC to 36 VDC via an external power supply unit (available as an accessory, not included as standard).

DC 12-36V socket

IMPORTANT NOTE: To avoid damaging the device, please use only one of the two sockets at a time.

Connection to the screw terminal

  1. Connect the ‘+’ lead from your DC power supply to the ‘+’ input of the screw terminal.
  2. Connect the ‘-‘ lead to the ‘-‘ input of the screw terminal.
  3. To avoid potential differences and damage to the USB or communication interfaces, never connect the Box PC to multiple devices with different earth potentials.

7.1. 2-pole terminal

2-pole terminal block with labels 12-36V and GND

Compatible with: 7th to 10th Generation Intel® Core™ processors

12-pole terminal

Close-up of a green 12-pin terminal strip.

Compatible with: 12th Generation Intel® Core™ processors and Intel® Celeron® J6412

Layout of the Interfaces

Intel® Celeron® J6412 Processor
Front view showing interfaces:Front view of the Intel Celeron J6412 module.

Rear view with terminal strip:

Rear view of the Intel Celeron J6412 module.

Intel® Core™ Processors (7th to 10th Generation)
Front view showing interfaces:Front view of the BPC00x device showing various ports.

Rear view with terminal strip:

Rear view of the BPC00x device with a terminal strip installed.

Intel® Core™ Processor (12th Generation)
Front view showing interfaces:Front view of the BPC00x device showing ports.

Rear view with terminal strip:

Logo of the company, featuring a stylized blue 'W' shape.Rear view of the BPC00x-xxxxxxxxxxxxxxxxxx2P device showing various ports: a green 12-pin screw terminal block, a USB port, and two Wi-Fi antennas.

Interfaces

Intel® Celeron® J6412 Processor

Interface Quantity and Description
USB 4x USB 2.0 Typ A, 2x USB 3.0 Typ A
Serial 4x RS-232 DB-9 (RS-485/422 on request)
Ethernet 2x RJ-45 Gigabit Ethernet (electrically isolated)
Wi-Fi 1x IEEE 802.11a/b/g/n
Bluetooth 1x Bluetooth
Display 1x HDMI, 1x VGA
Audio 1x Audio In/Out, 3.5 mm jack

7th to 10th Generation Intel® Core™ Processors

Interface Quantity and Description
USB 4x USB 2.0 Typ A, 2x USB 3.0 Typ A
Serial 6x RS-232 DB-9 (RS-485/422 on request)
Ethernet 2x RJ-45 Gigabit Ethernet (electrically isolated)
Wi-Fi 1x IEEE 802.11a/b/g/n
Bluetooth 1x Bluetooth
Display 1x HDMI, 1x VGA
Audio 1x Audio In/Out, 3.5 mm jack

2-pole screw terminal (included)

Close-up of the 2-pole screw terminal block, showing two terminals labeled '12-36V' and 'GND'.

PIN Description
1 DC+: 12-36 VDC (supply)
2 DC-: GND (supply)

12th Generation Intel® Core™ Processor

Interface Quantity and Description
USB 4x USB 2.0 Typ A, 2x USB 3.0 Typ A
Serial 4x RS-232 DB-9 (RS-485/422 on request)
Ethernet 2x RJ-45 Gigabit Ethernet (electrically isolated)
Wi-Fi 1x IEEE 802.11a/b/g/n
Bluetooth 1x Bluetooth
Display 1x HDMI, 1x VGA
Audio 1x Audio In/Out, 3.5 mm jack
GPIO 5x GPIO terminal strip

12-pin screw terminal (included)
PLEASE NOTE: By default, only the 12-pin screw terminal is used for the power supply. The use of the other interfaces is subject to restrictions, and technical feasibility must be assessed on a case-by-case basis for each project.

A green 12-pin screw terminal block with pins numbered 1 to 12. The labels below the pins are: 12-36V, GND, GND, TX, RX, 485A, 485B, IO0, IO1, IO2, IO3, IO4.

PIN Description
1 12-36 VDC (supply)
2 GND (supply)
3 GND
4 RS232 TX
5 RS232 RX
6 RS485A
7 RS485B
8 IO0 (TTL)
9 IO1 (TTL)
10 IO2 (TTL)
11 IO3 (TTL)
12 IO4 (TTL)

This document is the property of Wachendorff Prozesstechnik GmbH & Co. Copying and reproduction are prohibited without prior authorisation. The contents of this documentation refer to the device described therein.

Disclaimer

All technical content within this document may be modified without prior notice. The content of this document is subject to periodic revision. Repairs will be charged to the user in the event of loss due to fire, earthquake, third-party interference or other accidents, or in the event of intentional or accidental misuse or abuse, or use under abnormal conditions. Wachendorff Prozesstechnik is not liable for accidental loss due to use or non-use of this product, such as loss of business revenue. Wachendorff Prozesstechnik is not liable for the consequences of improper use.

Other Provisions and Standards

WEEE InformationWEEE disposal symbol: a crossed-out wheeled bin. Disposal of old electrical and electronic equipment (valid in the European Union and other European countries with a separate collection system) This symbol on the product or on the packaging means that this product must not be treated as household waste. Instead, this product should be taken to the appropriate disposal point for the recycling of electrical and electronic equipment. If the product is disposed of correctly, you will help to prevent negative environmental impacts and damage to health that could be caused by improper disposal. Recycling material will preserve our natural resources. For more information on how to recycle this product, please contact your local city office, your household waste collection service or the retailer where you purchased this product.

Technical Consulting & Service

If you have any questions about the product, you can find technical support on our website:  https://www.wachendorff-prozesstechnik.de/kontakt/technische-beratung-service/

  • For technical support after a purchase (commissioning, project planning, parameterization, configuration, programming, etc.): Please dial +49 6722 9965-966 or send an e-mail to support@wachendorff.de
  • For application advice before a possible purchase (product selection, suitability, recommendation): Please call +49 6722 9965-20 or send an e-mail to wp@wachendorff.de In the event of a repair or device failure, please contact our technical advice & service department first. More than 75% of all cases are resolved over the phone, saving you any costs or the shipping of your product. You will also receive information on the return procedure.  To return the product, please go to our homepage at https://www.wachendorff-prozesstechnik.de/garantie-und-reparatur, open the “Form for requesting a return number” and follow the instructions. After we have checked your form, we will send you a document with a return number (RSN) by e-mail. Please enclose this document with your return shipment.

Please note:
The return shipment number (RSN) is generated specifically for your return shipment. It regulates the conditions and ensures direct allocation and faster processing of your return. It is therefore extremely important that the RSN is enclosed with your return.  Wachendorff Prozesstechnik GmbH & Co.KG Industriestraße 7 65366 Geisenheim, GERMANY Phone: +49 6722 996520 E-Mail: wp@wachendorff.de Web: www.wachendorff-prozesstechnik.de

QR code linking to the company information

Troubleshooting Guidance

  • Device may fail or enter an unsafe state due to internal faults: The manual notes that the equipment may fail due to an internal fault and could cause an unsafe state. Implement appropriate system-level safety precautions.
  • Unintended startup/safety risk: Electrical faults in the user interface may cause connected equipment to start unintentionally, potentially causing property damage or operator injury. If PLCs require operator intervention, take appropriate precautions based on the system safety risks.
  • Interference or improper operation: Although electronics are protected against external electrical influences, there may be no complete protection in certain circumstances. Ensure correct cable routing and proper earthing.
  • Power/connection issues: Ensure the DC power source is SELV-compliant and provides isolation from mains and similar hazards. Use the specified DC fuse rating and have fuse replacement performed by qualified personnel.
  • Communication/interface damage risk: Do not connect the Box PC to multiple devices with different earth potentials; this can cause potential differences and damage to USB or communication interfaces.

Documents / Resources

PDF thumbnailBox-PC
Instruction Manual · BPC00x-xxxxxxxxxxxxxxxxx2P, Hdrm100 L1 4G Lte Wireless Cat 3 Cat 4 Router, Hdrm100, L1 4G Lte Wireless Cat 3 Cat 4 Router, Wireless Cat 3 Cat 4 Router, Cat 4 Router

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.