VIVREAU logoPURITY C
PURITY C Quell ST / PURITY C Quell ST Advanced
PURITY C Finest / PURITY C Steam Advanced
PURITY C1000 AC / PURITY C XtraSafe
Water Filter SystemVIVREAU PURITY C Water Filter Systemversion 10/2024

PURITY C Water Filter System

VIVREAU PURITY C Water Filter System - PartsVIVREAU PURITY C Water Filter System - Figure

PURITY C Quell ST / PURITY C Quell ST Advanced

Bypass and capacity tables
Filter Heads PURITY C 0–70 % with variable bypass
Coffee and espresso machines/vending machines

VIVREAU PURITY C Water Filter System - Coffee and espresso machines

PURITY C Finest
Bypass and capacity tables

Filter Heads PURITY C 0 % bypass
Coffee and espresso machines

Total hardness °dh Grains per US gallon Recom­ mended  bypass setting PURITY C Finest ­ Filter capacity in litre
PURITY C500 Finest PURITY C1100 Finest
Liters US gallons Liters US gallons
4 4 0% 5690 1503 10000 2642
5 5 0% 5690 1503 10000 2642
6 6 0% 5690 1503 10000 2642
7 7 0% 4877 1288 8571 2264
8 8 0% 4268 1127 7500 1981
9 9 0% 3793 1002 6667 1761
10 10 0% 3414 902 6000 1585
11 11 0% 3104 820 5455 1441
12 12 0% 2845 752 5000 1321
13 13 0% 2626 694 4615 1219
14 14 0% 2439 644 4286 1132
15 15 0% 2276 601 4000 1057
16 16 0% 2134 564 3750 991
17 17 0% 2008 530 3529 932
18 18 0% 1897 501 3333 880
19 19 0% 1797 475 3158 834
20 20 0% 1707 451 3000 793
21 21 0% 1626 430 2857 755
22 22 0% 1552 410 2727 720
23 23 0% 1484 392 2609 689
24 24 0% 1423 376 2500 660
25 25 0% 1366 361 2400 634
26 26 0% 1313 347 2308 610
27 27 0% 1264 334 2222 587
28 28 0% 1219 322 2143 566
29 29 0% 1177 311 2069 547
30 30 0% 1138 301 2000 528
31 31 0% 1101 291 1935 511
32 32 0% 1067 282 1875 495
33 33 0% 1035 273 1818 480
34 34 0% 1004 265 1765 466
35 35 0% 975 258 1714 453

PURITY C Steam Advanced
Bypass and capacity tables

Filter Heads PURITY C Steam 0–3 with variable bypass
Combi ovens and conventional ovens

German carbonate hardness °dh Grains per US gallon PURITY C Steam Advanced – Filter capacity in litre
PURITY C500 Steam Advanced
Recommended bypass setting
0 0 1/2 1/2 3 3
Liters US gallons Liters US gallons Liters US gallons
4 4 7083 1871 7792 2058 8677 2292
5 5 7083 1871 7792 2058 8677 2292
6 6 7083 1871 7792 2058 8677 2292
7 7 6071 1604 6679 1764 7438 1965
8 8 5313 1403 5844 1544 6508 1719
9 9 4722 1247 5194 1372 5785 1528
10 10 4250 1123 4675 1235 5206 1375
11 11 3864 1021 4250 1123 4733 1250
12 12 3542 936 3896 1029 4339 1146
13 13 3269 864 3596 950 4005 1058
14 14 3036 802 3339 882 3719 982
15 15 2833 748 3117 823 3471 917
16 16 2656 702 2922 772 3254 860
17 17 2500 660 2750 726 3063 809
18 18 2361 624 2597 686 2892 764
19 19 2237 591 2461 650 2740 724
20 20 2125 561 2338 617 2603 688
21 21 2024 535 2226 588 2479 655
22 22 1932 510 2125 561 2366 625
23 23 1848 488 2033 537 2264 598
24 24 1771 468 1948 515 2169 573
25 25 1700 449 1870 494 2083 550
26 26 1635 432 1798 475 2002 529
27 27 1574 416 1731 457 1928 509
28 28 1518 401 1670 441 1859 491
29 29 1466 387 1612 426 1795 474
30 30 1417 374 1558 412 1735 458
31 31 1371 362 1508 398 1679 444
32 32 1328 351 1461 386 1627 430
33 33 1288 340 1417 374 1578 417
34 34 1250 330 1375 363 1531 405
35 35 1214 321 1336 353 1488 393

The bypass position can be adjusted to the local water quality or the machine type.
Position 0: All devices in areas with an extremely high water hardness level (CH ≥ 22 °dH)
Position 1: Combi ovens and conventional ovens with direct injection system
Position 2: Combi ovens and conventional ovens with boiler system
Position 3: All devices in soft water areas (CH ≤ 7 °dH)
You can obtain individual recommendations from your VIVREAU contact.
Operation of filter only with PURITY C Steam filter head.

PURITY C Steam Advanced
Bypass and capacity tables

Filter Heads PURITY C Steam 0–3 with variable bypass
Combi ovens and conventional ovens

German carbonate
hardness °dh
Grains per US gallon PURITY C Steam Advanced – Filter capacity in litre
PURITY C1100 Steam Advanced
Recommended bypass setting
0 0 1/2 1/2 3 3
Liters US gallons Liters US gallons Liters US gallons
4 4 11980 3165 13178 3481 14676 3877
5 5 11980 3165 13178 3481 14676 3877
6 6 11980 3165 13178 3481 14496 3829
7 7 10269 2713 11295 2984 12425 3282
8 8 8985 2374 9884 2611 10872 2872
9 9 7987 2110 8785 2321 9664 2553
10 10 7188 1899 7907 2089 8697 2298
11 11 6535 1726 7188 1899 7907 2089
12 12 5990 1582 6589 1741 7248 1915
13 13 5529 1461 6082 1607 6690 1767
14 14 5134 1356 5648 1492 6212 1641
15 15 4792 1266 5271 1392 5798 1532
16 16 4493 1187 4942 1305 5436 1436
17 17 4228 1117 4651 1229 5116 1352
18 18 3993 1055 4393 1160 4832 1276
19 19 3783 999 4161 1099 4578 1209
20 20 3594 949 3953 1044 4349 1149
21 21 3423 904 3765 995 4142 1094
22 22 3267 863 3594 949 3953 1044
23 23 3125 826 3438 908 3782 999
24 24 2995 791 3295 870 3624 957
25 25 2875 760 3163 835 3479 919
26 26 2765 730 3041 803 3345 884
27 27 2662 703 2928 774 3221 851
28 28 2567 678 2824 746 3106 821
29 29 2479 655 2726 720 2999 792
30 30 2396 633 2636 696 2899 766
31 31 2319 613 2551 674 2806 741
32 32 2246 593 2471 653 2718 718
33 33 2178 575 2396 633 2636 696
34 34 2114 558 2326 614 2558 676
35 35 2054 543 2259 597 2485 656

The bypass position can be adjusted to the local water quality or the machine type.
Position 0: All devices in areas with an extremely high water hardness level (CH ≥ 22 °dH)
Position 1: Combi ovens and conventional ovens with direct injection system
Position 2: Combi ovens and conventional ovens with boiler system
Position 3: All devices in soft water areas (CH ≤ 7 °dH)
You can obtain individual recommendations from your VIVREAU contact.
Operation of filter only with PURITY C Steam filter head.

Test data for PURITY C50 Quell ST

Substance Guidelines Average Influent Concentration Maximum Effluent Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %

* Test data for PURITY C150 Quell ST

Substance Guidelines Average Influent Concentration Maximum Effluent  Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %

* Test data for PURITY C300 Quell ST Advanced

Substance Guidelines Average Influent Concentration Maximum Effluent  Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %

Test data for PURITY C500 Quell ST Advanced

Substance Guidelines Average Influent Concentration Maximum Effluent  Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.1 mg/l 0.31 mg/l 85.2 % 0.25 mg/l 88.6 %

** Test data for PURITY C1100 Quell ST Advanced

Substance Guidelines Average Influent Concentration Maximum Effluent Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.1 mg/l 0.31 mg/l 85.2 % 0.25 mg/l 88.6 %

* Values calculated on basis of the PURITY C50 Quell ST
** Values calculated on basis of the PURITY C500 Quell ST Advanced

Testing conditions

Flow rate PURITY C50 Quell ST: 0.25 GPM pH: 7.5 +/– 0.5
Flow rate PURITY C500 Quell ST: 0.44 GPM pH: 7.5 +/– 0.5
Pressure: 60 +/– 3 psi
Temperature: 20 +/– 3 °C

Capacity and flow rate table based on chlorine reduction

Water filter system PURITY C50 Quell ST PURITY C150 Quell ST PURITY C300 Quell ST Advanced PURITY C500  Quell ST Advanced PURITY C1100  Quell ST Advanced
Capacity 1900 Liters/ 502 gallons 4766 Liters/ 1259 gallons 7917 Liters/ 2091 gallons 13458 Liters/ 3555 gallons 22762 Liters/ 6013 gallons
Rated service flow (lpm) 0.25 gallons/min 0.25 gallons/min 0.25 gallons/min 0.44 gallons/min 0.44 gallons/min

Capacity and flow rate table based on chloramine reduction

Water filter system PURITY C300 Quell ST Advanced PURITY C500 Quell ST Advanced PURITY C1100 Quell ST Advanced
Capacity 7917 Liters/ 2091 gallons 13458 Liters/ 3555 gallons 22762 Liters/ 6013 gallons
Rated service flow (lpm) 0.25 gallons/min 0.44 gallons/min 0.44 gallons/min

PURITY C AC
The PURITY C1000 AC filter system has a filter capacity of 10,000 litres (2641 US gallons), regardless of carbonate hardness and the bypass set. All intake water is filtered (Chapter 4.2).

Substance reduction
This system has been tested according to NSF/ANSI 42 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.

Test data for PURITY C1000 AC

Substance Guidelines Average Influent Concentration Maximum Effluent
Concentration
Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.1 mg/l 0.05 mg/l 97.4 % 0.05 mg/l 97.6 %
Substance Influent challenge concentration Reduction requirement Overall percent reduction
Particulate, class 1 particles 0.5 to < 1µm At least 10.000 particles/ml ≥ 85 % 98.90 %

Testing conditions

Flow rate PURITY C1000 AC: 0.79 GPM
Pressure: 60 +/– 3 psi
Temperature: 20 +/– 3 °C

Test data for PURITY C500 Finest

Substance Guidelines Average Influent Concentration Maximum Effluent  Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.0 mg/l ND (0.05 mg/l) (not detectable) 97.4 % ND(0.05 mg/l) (not detectable) >97.5 %

Test data for PURITY C1100 Finest

Substance Guidelines Average Influent Concentration Maximum Effluent  Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.0 mg/l ND (0.05 mg/l) (not detectable) 97.4 % ND(0.05 mg/l) (not detectable) >97.5 %

Test data for PURITY C500 Steam Advanced

Substance Guidelines Average Influent Concentration Maximum Effluent
Concentration
Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.1 mg/l 0.31 mg/l 85.2 % 0.25 mg/l 88.6 %

*Test data for PURITY C1100 Steam Advanced

Substance Guidelines Average Influent Concentration Maximum Effluent
Concentration
Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.1 mg/l 0.31 mg/l 85.2 % 0.25 mg/l 88.6 %

* Values calculated on basis of the C500

Testing Conditions:

Flow Rate: 0.25 GPM pH: 7.5+/–0.5
Pressure: 60+/– 3 psgi Temperature: 20+/–3 °C

Capacity and flow rate table based on chlorine and chloramine reduction

Water filter system PURITY C500 Steam Advanced PURITY C1100 Steam Advanced
Capacity 7792 Liters/ 2058 gallons 13178 Liters/ 3481 gallons
Rated service flow (lpm) 0.44 gallons/min 0.44 gallons/min

PURITY C XtraSafe
For PURITY C1100 XtraSafe please use the VIVREAU Professional Filter website for individual capacity calculation:

  • Please go to the capacity calculation on the website https://vivreauwater.com/products/purity-c1100-xtrasafe/
  • Enter locally measured Carbonate Hardness, Total Hardness and Conductivity
  • Important: Set the by-pass accordingly, track the individually calculated capacity and change the cartridge in time!
    All the intake water is filtered.

Test data for PURITY C XtraSafe

Substance Guidelines Average Influent Concentration Maximum Effluent Concentration Minimum Percent Removal Average Effluent Concentration Average Percent Removal
Chlorine NSF/ANSI 42 2.0 mg/l 0.19 mg/l 90.7 % 0.10 mg/l 95.2 %

Testing Conditions:

Flow Rate: 0.52 GPM pH: 7.5+/–0.5
Pressure: 60+/– 3 psgi Temperature: 20+/–3 °C

Definition of Terms

All filter head types:

  1. Filter head
  2. Locking handle
  3. Water outlet (1/2”-14 NPT, G3/8” or JG8)
  4. Water inlet (1/2”-14 NPT, G3/8” or JG8)
  5. Wall mounting bracket
  6. Filter cartridge
  7. Protective cap
  8. Flush valve
  9. Flush hose
    Additionally for filter head types PURITY C 0 – 70%:
  10. Bypass setting
  11. Flush valve with slider
    Additionally for filter head types PURITY C with John Guest connection:
  12. Safety clips

General Information

2.1 Function and Application
PURITY C is a filter system specially designed by VIVREAU for use in catering to ensure constantly high water quality for individual customer applications as well as reliable and simple operation.
The unique IntelliBypass ensures a nearly constant bypass proportion for the entire usage period, irrespective of the volumetric flow of the terminal equipment used. The result is consistently high water quality specially tailored to the requirements of the application and the local water conditions.
By reliably locking the filter cartridge in the filter head and controlling the water flow, the innovative locking handle ensures simple and reliable operation.
The food quality provided by the VIVREAU PURITY C filter system has been tested and confirmed by independent institutes. Product-specific certifications are located on the label and also at www.vivreau.com/professional-filters

2.1.1 PURITY C Quell ST / PURITY C Quell ST Advanced
PURITY C Quell ST / PURITY C Quell ST Advanced filter cartridges reduce the carbonate hardness* in drinking water, thus preventing scale deposits in the downstream terminal equipment.
Depending on the bypass setting, calcium*, magnesium* and metal ions* can be selectively removed from the drinking water during the flow process.
In addition to cloudiness* and organic pollutants*, the filter material also reduces the level of substances impairing smell and taste, such as chlorine and chloramine¹ residues in the filtrate and the bypass water.
Typical areas of applications for PURITY C Quell ST are coffee and espresso machines, hot and cold drink vending machines as well as combi ovens and conventional ovens.

*Not performance tested and certified by NSF.
¹Only for PURITY C Advanced

2.1.2 PURITY C Finest
The PURITY C Finest filtrate helps to produce the unique coffee aroma – especially in espressos – and allows the body of the coffee to develop. The characteristics of the coffee crema are experienced in their full intensity. The PURITY C Finest filter cartridges reduce the total hardness* in drinking water, thereby avoiding limescale and gypsum deposits in the downstream appliance. Calcium*, magnesium* and metal ions* are selectively removed from the drinking water using the flow method.

The filter material not only reduces cloudiness* and organic pollutants*, but also the level of substances that impair the smell and taste, such as chlorine residues in the filtrate. The PURITY C Finest is typically used in coffee and espresso machines.
VIVREAU PURITY C Water Filter System - icon Caution: The PURITY C Finest is not suitable for use with combi ovens and conventional ovens. Operation is not recommended in combination with domestic water-softening systems.
PURITY C Finest cartridges must be operated with a bypass setting of 0%.

2.1.3 PURITY C Steam Advanced
The PURITY C Steam water filter system optimises tap water specially for combi ovens and conventional ovens. It decarbonates drinking water, thereby reducing scale deposits in and on the terminal equipment. Depending on the bypass setting, calcium* and magnesium ions* as well as metal ions* such as lead and copper are selectively removed from the drinking water. In addition, the filter material not only reduces turbidity* and organic impurities* but also substances that impair smell and taste, such as chlorine and chloramine.
The bypass setting, which is specially designed for combi ovens and conventional ovens, matches the reduction in the carbonate hardness to the local water hardness in order to achieve an optimum filtrate quality. The increased flow and the reduced pressure loss enable the smooth operation of the combi oven.

2.1.4 PURITY C AC
The PURITY C1000 AC filter cartridge reduces cloudiness*, organic pollutants* as well as the level of substances impairing smell and taste, such as chlorine residues. The filter material retains particles down to a size of 0.5 µm.
Typical areas of application for PURITY C1000 AC are vending machines and on-tap watercoolers.

2.1.5 PURITY C XtraSafe
The VIVREAU PURITY C1100 XtraSafe water filter system optimizes tap water specially for coffee and vending machines as well as for combi ovens and conventional ovens in gypsum and corrosive water areas. With complete desalination of drinking water, it is reducing scale and gypsum deposits and risk of corrosion in and on the terminal equipment. Calcium and magnesium ions, chlorides and sulphates as well as metal ions such as lead and copper are selectively removed from the drinking water. In addition, the filter material not only reduces turbidity but also substances that impair smell and taste, such as chlorine.

The recommended by-pass setting, which is specially designed for Coffee and Steam applications, matches the reduction in electrical conductivity in order to achieve an optimum filtrate quality and to protect the machines. The increased flow and the reduced pressure loss enable the smooth operation of the combi oven. The PURITY C1100 XtraSafe filter cartridge must be replaced once the filter capacity calculated individually on the VIVREAU Professional FIlter website has been reached, in accordance with manufacturer´s specifications or no later than 12 months after commissioning, whichever occurs first. For tracking, the usage of a VIVREAU FlowMeter is highly recommended.

Coffee & Vending: Filter head: Individual bypass recommendation via VIVREAU website
Coffee and espresso machines/Vending machines Filter Heads PURITY C 0–70 % with variable bypass 40 % / 30 %
Operation of filter only with PURITY C 0–70 % filter head.
Steam: Filter head: Recommended bypass setting
Combi ovens and conventional ovens Filter Heads PURITY C Steam 0-3 with variable by-pass 2
Operation of filter only with PURITY C Steam filter head.

2.2 Warranty Provisions
The PURITY C filter system is subject to the warranty of 2 years. A warranty claim may only be asserted only if all instructions in this manual are followed and observed.

2.3 Storage/Transport
Adhere to the ambient conditions for storage and transport detailed in the technical data (Chapter 9).
The manual should be seen as part of the product and kept for the whole service life of the filter system and passed on to subsequent owners.

2.4 Recycling/Disposal
The packaging material is suitable for recycling and can be reused. Please dispose of all materials in accordance with local regulations.
VIVREAU takes back used filter cartridges for recycling at the addresses listed on the back of the cover, or the cartridges can be disposed of according to local regulations.
If you decide not to return the filter cartridges, please dispose of all materials in accordance with local regulations.

Operating and Safety Information

3.1 Qualified personnel
Installation and maintenance of the filter system may only be carried out by trained or authorised personnel.

3.2 Correct use
Perfect and safe operation of the product is subject to the installation, use and maintenance described in this manual. Only use filter cartridges intended for use with your filter system.

3.3 Liability exclusion
Installation and cartridge exchanges must be performed precisely in accordance with the instructions in this manual.
VIVREAU shall not be held liable for any damage, including subsequent damage, arising from the incorrect installation or use of the product.

3.4 Specific safety information

  • Water used as intake water for the PURITY C water filter system must be of drinking water quality. The PURITY C water filter system is only suitable for cold water use within the water intake temperature range stated in Chapter 9. No microbiologically impaired water or water of unknown quality may be used without appropriate disinfection.
  • If there are official instructions to boil tap water, the filter system must be decommissioned. When the requirement to boil water comes to an end, the filter cartridge must be replaced and the connections cleaned.
  • It is generally recommended to boil tap water for certain groups of people (e.g. people with weakened immune systems, babies). This also applies to filtered water.
  • Note for people with kidney disease or dialysis patients: during the filter process, the potassium content may be increased slightly. If you suffer from kidney disease and/or have to stick to a special potassium diet, we recommend you consult your doctor beforehand.
  • VIVREAU recommends not to decommission the filter system for long periods. If the VIVREAU PURITY C filter system is not used for several days, we recommend that the filter system be flushed with the volume of water indicated in the table below.
    Filter cartridge Flushing volume from 2 days to 1 week not used Flushing volume > 1 week not used
    PURITY C50 2 liters (0.5 US gallons) 20 liters (5.3 US gallons)
    PURITY C150 3 liters (0.8 US gallons) 30 liters (7.9 US gallons)
    PURITY C300 6 liters (1.6 US gallons) 60 liters (15.9 US gallons)
    PURITY C500 10 liters (2.6 US gallons) 100 liters (26.4 US gallons)
    PURITY C1100 18 liters (4.76 US gallons) 180 liters (47.6 US gallons)
    PURITY C1000 AC 1 liter (0.26 US gallons) 10 liters (2.6 US gallons)
  • The filter system must not be opened or dismantled during operation. The filter cartridge must not be opened.
  • Production date
    Production code filter head – example: H 8375 01381
    8 Production year, this example: 2018
    37 Production week, this example: calendar week 37
    5 Production day from Monday (1) to Sunday (7), this example: Friday
    01381 Serial identification number
    Production code filter cartridge – example: B8224350010
    8 Production year, this example: 2018
    22 Production week, this example: calendar week 22
    4 Production day from Monday (1) to Sunday (7), this example: Thursday
    35 Internal Identification No. of filter medium, this example No. 35
    0010 Consecutive number of the filter cartridge, this example the tenth cartridge; reset when the day changes

3.5 Technical safety assembly instructions

  • The appliance in which the filter is used must be free of limescale prior to installation.
  • Protect the filter system from sunlight and mechanical damage. Do not assemble near sources of heat and open flames.
  • A stop valve must be installed before the filter system inlet hose.
  • If the water pressure is higher than 8.6 bar (125 psi), a pressure reducer must be installed in front of the filter system.
  • When choosing the material for parts that come into contact with water after the VIVREAU filter system, it is important to remember that, due to the process, decarbonised water contains free carbon dioxide. For this reason, only materials that are compatible with free carbon dioxide must be used.
    Note: The water is not decarbonised when using PURITY C AC filter cartridges.
  • All parts must be installed in accordance with the country-specific guidelines on the installation of drinking water facilities.

Installation

warning 2 Caution: Prior to installation, read the technical data (Chapter 9) and the operating and safety information (Chapter 3). After storage and transport below 0 °C (32 °F), the product must be stored in the open original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures (Chapter 9) for operation.

4.1 Assembling the filter head, water connection

VIVREAU PURITY C Water Filter System - icon 1VIVREAU PURITY C Water Filter System - icon 2VIVREAU PURITY C Water Filter System - icon 3VIVREAU PURITY C Water Filter System - icon 4 ● Close the water intake and switch off the power supply to the end device.
● Fit the wall mounting bracket ⑤ in the intended position.
warning 2 Caution: When fitting the bracket, note the installation dimensions, bending radii of the hoses and dimensions of the accessories (e.g. VIVREAU Flow Meter). When using the wall mount, install vertically only! The PURITY C1100 cannot be installed using the wall mounting bracket.
● Fit the hoses to the water inlet “IN” ④ and outlet “OUT” ③ on the filter head ①.
warning 2 Caution: The max. tightening torque at the connections must not exceed 14 Nm!
● When using PURITY C 0-70% filter heads, check bypass setting 10 (set to 30% at the factory) and if necessary adjust this setting to the local carbonate hardness (chapter 4.2).
● Lock the filter head ① in the wall mounting bracket ⑤.

4.2 Bypass setting for and capacity of PURITY C 0 – 70% filter heads

  • Determine the carbonate hardness (for PURITY C filter cartridges) by performing the VIVREAU carbonate hardness test. Alternatively, your local water supplier will be able to provide information on the local water hardness.
  • Determine the bypass setting and capacity in line with the application and the carbonate hardness identified using the bypass and capacity table (pages 2–5).
  • Then turn the bypass setting 10 to the identified value.
  • To ensure precise and continuous control of the degree of filter cartridge exhaustion, it is recommended to install the VIVREAU FlowMeter 10 – 100 A.
  • Note: With PURITY C1000 AC and PURITY C Finest filter cartridges, all of the intake water is filtered. The filter cartridge can be used with filter heads that have a variable or fixed bypass. The bypass that may be set in the filter head is not taken into account.

4.3 Inserting the filter cartridge

VIVREAU PURITY C Water Filter System - icon 5 ● Pull the flap of the protective cap ⑦ upwards and remove the protective cap.
● Note the next exchange date in the date field on the filter cartridge ⑥.
● Insert the filter cartridge ⑥ in the filter head ① in a vertical position.
VIVREAU PURITY C Water Filter System - icon Caution: The filter cartridge can only be inserted when the locking handle is open.
● Make sure that the filter cartridge is positioned correctly.
● Turn the locking handle ② until you feel it engage.

4.4 Commissioning

VIVREAU PURITY C Water Filter System - icon 6 • Open the water intake and switch on the terminal equipment’s power supply.
• Operate the flush valve ⑧ and flush the filter system until the filtered water runs clear and without bubbles. At least two empty filter cartridge volumes must be flushed ( Chapter 9).
Note: When bleeding/flushing, catch water emerging from the flush hose ⑨ in an appropriate container.
• Check system for any leaks.

Changing the filter cartridge

The PURITY C filter cartridge must be replaced once the stated capacity has been reached (see Chapter 6), in accordance with manufacturer´s specifications or no later than 12 months after commissioning, whichever occurs first.

VIVREAU PURITY C Water Filter System - icon Caution: When changing a filter cartridge, examine all remaining parts carefully! Faulty parts must be exchanged and contaminated parts should be cleaned. Read the operating and safety information (Chapter 3) before changing the cartridge. After storage and transport below 0 °C (32 °F) the product must be stored in the open original packaging for at least 24 hours before it is commissioned at the stated ambient temperatures (Chapter 9) for operation. !

Note: When the locking handle is open, the water supply to the cartridge is interrupted and short circuit operation with direct water flow from the water inlet ④ to the water outlet ③ is possible (if necessary, close the water intake and switch off the power supply to the terminal equipment).

  • Open locking handle ②.
  • Activate the flush valve ⑧ and depressurise the system.
  • Remove exhausted filter cartridge ⑥ from the filter head ①, bearing in mind the weight of the car tridge. Note: The filter cartridge can be pivoted by 90 ° in the wall mounting bracket for easy removal.
  • Perform the steps described at 4.3 and 4.4.

Bypass and capacity tables

The capacity tables for the PURITY C filter systems are provided on pages 2–5. The capacities shown in the capacity tables are based on German carbonate hardness and are not certified by NSF.
Note: The stated capacities were tested and calculated based on standard application and machine conditions. This information may vary according to external influencing factors.
The PURITY C1000 AC has a filter capacity of 10,000 litres, regardless of the carbonate hardness and the bypass set. All intake water is filtered.
For PURITY C1100 XtraSafe please use the VIVREAU Professional Filter website for individual capacity calculation:

  • Please go to the capacity calculation on the website https://vivreauwater.com/products/purity-c1100-xtrasafe/
  • Enter locally measured Carbonate Hardness, Total Hardness and Conductivity
  • Important: Set the by-pass accordingly, track the individually calculated capacity and change the cartridge in time!

Repair

Regularly check the filter system for leaks. Regularly check the hoses for kinks. Bent hoses must be replaced.
The complete filter system must be replaced in rotation after a maximum of ten years. The hoses must be replaced in rotation after a maximum of five years.

VIVREAU PURITY C Water Filter System - icon Caution: Before replacing filter systems or hoses, read the technical data (Chapter 9) and the operating and safety information (Chapter 3).
Regularly clean the outside of the filter system with a soft, damp cloth.
VIVREAU PURITY C Water Filter System - icon Caution: Do not use any abrasive chemicals, cleaning solutions or astringent cleaning agents.

Troubleshooting

8.1 No water flow

Cause: Water intake closed.
Troubleshooting:  Open the water intake at the upstream stop valve or by closing the locking handle ② on the filter head ①.

8.2 No or low water flow in spite of open water intake

Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues, check the filter system and filter cartridge and replace if necessary.
Cause: Filter head not mounted in direction of flow.
Troubleshooting: Dismantle filter head and install in direction of flow (Chapter 4).

8.3 Leak

Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed connections and mount according to Chapter 4. If the fault persists, replace filter system.

Technical Data

9.1 PURITY C Quell ST

PURITY C Filter System with Filter Cartridge
PURITY C50  Quell ST PURITY C150  Quell ST PURITY C300  Quell ST Advanced PURITY C500  Quell ST Advanced PURITY C1100  Quell ST Advanced
Operating pressure 2 bar – max. 8.6 bar (29 psi – max. 125 psi)
Water intake temperature 4 °C – 30°C (39.2 °F – 86 °F)
Ambient temperature during operation 4 °C – 40 °C (39.2 °F – 104 °F)
Storage/transport -20 °C – 50 °C (-4 °F – 122 °F)
Flow rate with 1 bar pressure loss (14.5 psi) 160 l/h
(42.27 US gallons/h)
145 l/h (38.30 US gallons/h) 140 l/h
(36.99 US  gallons/h)
140 l/h
(36.99 US gallons/h)
150 l/h
(39.63 US gallons/h)
Nominal flow 60 l/h
(15.85 US gallons/h)
60 l/h (15.85 US gallons/h) 60 l/h
(15.85 US gallons/h)
100 l/h
(26.41 US gallons/h)
100 l/h
(26.42 US gallons/h)
Pressure loss at nominal flow 0.25 bar (3.6 psi) 0.25 bar (3.6 psi) 0.25 bar (3.6 psi) 0.5 bar (7.3 psi) 0.5 bar (7.3 psi)
Empty filter cartridge volume 1.0 l
(0.26 US gallons)
1.9 l
(0.5 US gallons)
2.9 l
(0.8 US gallons)
5.4 l
(1.4 US gallons)
8.7 l
(2.3 US gallons)
Weight (dry/wet) 1.0/1.6 kg (2.2/3.5 lb) 1.8/2.8 kg (4/6.2 lb) 2.8/4.2 kg (6.2/9.3 lb) 4.6/6.9 kg (10.1/15.2 lb) 7.7 /12.5 kg (16.9/27.5 lb)
Dimensions of filter system (filter head with filter cartridge) (Width/Depth/Height) 119/108/268 mm (4.69/4.25/ 10.55 inch) 117/104/419 mm (4.60/4.09/ 16.5 inch) 125/119/466 mm (4.92/4.69/18.35 inch) 144/144/557 mm (5.67/5.67/21.93 inch) 184/184/557 mm (7.24/7.24/21.93 inch)
Dimensions (filter cartridge) with protective cap (Width/Depth/Height) 108/108/259 mm (4.25/4.25/10.19 inch) 104/104/410 mm (4.09 /4.09/16.14 inch) 119/119/457 mm (4.68/4.68/17.99 inch) 144/144/548 mm (5.67/5.67/21.58 inch) 184/184/548 mm (7.24/7.24/21.58 inch)
Installed dimensions (vertical installation with wall mounting) (Width/Depth/Height) 137/130/268 mm (5.39/5.11/10.55 inch) 137/128/419 mm (5.39/5.04/16.5 inch) 137/136/466 mm (5.39/5.35/18.35 inch) 144/148/557 mm (5.67/5.83/21.93 inch)
In addition to the accessories, the bending radii of the intake and outlet hose must be considered in addition to the dimensions of the complete system, depending on the installation orientation.
Operating position Horizontal or vertical
Inlet connection 1/2”-14 NPT, G3/8” or JG8
Outlet connection 1/2”-14 NPT, G3/8” or JG8

The PURITY C water filter system is used to remove carbonate hardness (temporary hardness/alkalinity)* from drinking water to prevent limescale deposits in downstream appliances. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Use cold water only. All of the materials used are safe for contact with drinking water. Observe relevant regulations. Read the manual prior to use.

9.2 PURITY C Finest, PURITY C AC, PURITY C Steam Advanced, PURITY C XtraSafe

PURITY C filter system with filter cartridge
PURITY C500 Finest PURITY C1100 Finest PURITY C1000 AC
Operating pressure 2 bar to max. 8.6 bar (29 psi – max. 125 psi)
Water intake temperature 4 °C to 30 °C (39.2 °F – 86 °F)
Ambient temperature during operation 4 °C to 40 °C (39.2 °F – 104 °F)
storage/transport -20 °C to 50 °C (-4 °F – 122 °F)
Flow rate with 1 bar pressure loss (14.5 psi) 140 l/h
(36.99 US gallons/h)
150 l/h
(39.63 US gallons/h)
140 l/h
(36.99 US gallons/h)
Nominal flow 100 l/h
(26.41 US gallons/h)
30 – 180 l/h
(7.9 – 47.55 US gallons/h)
Pressure loss at nominal flow 0.5 bar (7.3 psi) 0.2 – 1.4 bar (2.9 – 20.3 psi)
Empty filter cartridge volume 5.4 l 8.7 l 0.23 l
Weight dry 4.6 kg (10.1 lb) 7.7 kg (16.9 lb) 0.5 kg (1.10 lb)
wet 6.9 kg (15.2 lb) 12.5 kg (27.5 lb) 1.0 kg (2.20 lb)
Dimensions of filter system (filter head with filter cartridge) (Width/ Depth/Height) 144/144/557 mm (5.67/5.67/ 21.9 inch) 184/184/ 557 mm (7.24/7.24/ 21.93 inch) 109/93/ 238 mm (4.29/3.66/ 9.37 inch)
Dimensions (filter cartridge) (Width/ Depth/Height) 144/144/548 mm
(5.67/5.67/21.57 inch)
184/184/548 mm
(7.24/7.24/21.6 inch)
88/88/ 231 mm
(3.5/3.5/8.9 inch)
Installed dimensions (vertical installation with wall mounting) (Width/ Depth/Height) 144/148/557 mm
(5.67/5.83/21.9 inch)
137/120/238 mm
(5.39/4.72/9.37 inch)
In addition to the accessories (e.g. FlowMeter), the bending radii of the intake and outlet hose must be considered in addition to the dimensions of the complete system, depending on the installation orientation.
Operating position Vertical Horizontal or vertical
Inlet connection 1/2”-14 NPT, G3/8” or JG8
Outlet connection 1/2”-14 NPT, G3/8” or JG8
Nominal capacity 10,000 l 2641 US gallons
Chlorine reduction DIN EN 14898 > 90%
Chlorine reduction NSF 42 Class I (50%)
Particle retention NSF 42 Class I (0.5 μm)
PURITY C filter system with filter cartridge
PURITY C500 Steam Advanced PURITY C1100 Steam Advanced PURITY C1100 XtraSafe
Operating pressure 2 bar to max. 8.6 bar (29 psi – max. 125 psi)
Water intake temperature 4 °C to 30 °C (39.2 °F – 86 °F)
Ambient temperature during operation 4 °C to 40 °C (39.2 °F – 104 °F)
storage/transport -20 °C to 50 °C (-4 °F – 122 °F)
Flow rate with 1 bar pressure loss (14.5 psi) 300l/h (79.25 US gallons/h)
Nominal flow 100 l/h (26.41 US gallons/h)
Pressure loss at nominal flow 0.1 bar (1.5 psi) 0.2 bar (2.9 psi) 0.2 bar (2.9 psi)
Empty filter cartridge volume 5.4 l 8.7 l 8.7 l
Weight dry 4.6 kg (10.1 lb) 7.7 kg (16.9 lb) 7.7 kg (16.9 lb)
wet 6.9 kg (15.2 lb) 12.5 kg (27.5 lb) 12.5 kg (27.5 lb)
Dimensions of filter system (filter head with filter cartridge) (Width/ Depth/Height) 144/144/557 mm
(5.67/5.67/21.9 inch)
184/184/557 mm
(7.24/7.24/21.93 inch)
184/184/ 557 mm
(7.24/7.24/21.93 inch)
 

Dimensions (filter cartridge) (Width/ Depth/Height)

144/144/548 mm
(5.67/5.67/21.57 inch)
184/184/548 mm
(7.24/7.24/21.6 inch)
184/184/548 mm
(7.24/7.24/21.6 inch)
Installed dimensions (vertical installation with wall mounting) (Width/ Depth/Height) 144/148/557 mm
(5.67/5.83/21.9 inch)
In addition to the accessories (e.g. FlowMeter), the bending radii of the intake and outlet hose must be considered in addition to the dimensions of the complete system, depending on the installation orientation.
Operating position Horizontal or vertical Vertical
Inlet connection 1/2”-14 NPT
Outlet connection 1/2”-14 NPT
VIVREAU PURITY C Water Filter System - Symbol 1 PURITY C System tested and certified by NSF International against NSF/ANSI Standard 42 and CSA B483.1 for the reduction of Chlorine Taste and Odor.
VIVREAU PURITY C Water Filter System - Symbol 1 PURITY C Advanced System tested and certified by NSF International against NSF/ANSI Standard 42 and CSA B483.1 for the reduction of Chlorine and Chloramine Taste and Odor.

MAVEA LLC
300 Roundhill Drive, Unit 2
Rockaway, NJ 07866
USA
www.vivreau.com/professional-filters
profilters@vivreau.com
Information in the instruction for use subject to changeVIVREAU logo

Documents / Resources

VIVREAU PURITY C Water Filter System [pdf] Instruction Manual
C Quell ST, C Quell ST Advanced, C Finest, C Steam Advanced, C1000 AC, XtraSafe, PURITY C Water Filter System, PURITY C, Water Filter System, Filter System

References

Leave a comment