VIMAR 01910 Electronic Timer Thermostat
Electronic timer-thermostat for ON/OFF ambient temperature control (heating and air conditioning), daily/weekly programming, class I temperature control device (contribution 1%), change-over relay output 5(2) A 250 V~, powered by batteries AA LR6 1.5 V (not supplied), wall mounting.
MAIN CHARACTERISTICS
- Supply voltage: 3 V d.c. with 2 AA LR6 1,5 V batteries (not included)
- Batteries life: up to 1 year
- Output: 5(2) A 250 V~ change-over relay output
- Type of regulation: ON/OFF
- It is possible to create a radio link with actuators 01923 and 01924 by replacing the relay module with the transmitter module 01921.1
- Updating of display temperature: every 20 s
- Ambient temperature display range: 0 °C +40 °C
- Hysteresis: adjustable between 0,1 °C and 1 °C
- Thermostat operating range:
- +4 °C – +15 °C in antifreeze mode
- +5 °C – +35 °C in heating or cooling mode
- Principal functions:
- hourly temperature settings in 15-minute steps
- 3 programmable temperature set-points for heating + 3 temperature set-points for cooling + 1 antifreeze level
- weekly programming
- 1 automatic program that may be set by the user (for both heating and air-conditioning)
- possibility of forcing the program by manually adjusting the temperature
- regulation for both heating and cooling systems
- antifreeze function
- possibility of timed switch-off
- remote activation option via telephone dialler
- select between the display in degrees Celsius and Fahrenheit
- device reset
- Protection degree: IP30
- Class II equipment:
- Operating temperature: T40 (0 °C +40 °C)
- ErP classification (Reg. EU 811/2013): class I, contribution 1%
MAIN SETTINGS
Setting date and time
Before starting to program the timer-thermostat, it is advisable to set the current date and time.
- Press the
button; the device’s display will show only the arrow at the top indicating the date and time to set.
- Using the
button, move the arrow onto the current date.
- Press the
button to confirm and pass on to set the time; the two digits indicating the hour will start blinking.
- Set the current hour with the
button.
- Press the
button to confirm and pass on to set the minutes; the two digits indicating the minutes will start blinking.
- Set the current minutes with the
button.
- Press the
button to confirm and quit.
Setting manual operation
- If the timer-thermostat is working in automatic mode, press the
button to pass onto manual mode; the display will show the
.
- Using the
button, select the desired temperature then press the
button to confirm.
If necessary, wait approximately 5 seconds for the operation to be confirmed.
Setting automatic operation
If the timer-thermostat is working in manual mode, press the button to pass onto automatic mode; the display will show the histogram for the program’s day selection. In this case it is possible to pass onto manual mode temporarily, for example when the desired temperature is not the programmed temperature, by selecting the setting with the
button and waiting approximately 5 seconds for the operation to be confirmed. The new setting will remain active until the next programmed temperature level change, after which the saved program will be restored. To go back onto automatic operating mode immediately, press the
button.
Switch-off
- Press the button; the display will show the OFF symbol blinking alongside the temperature.
- Press the
button to confirm. To switch the timer thermostat back on, press the
button.
Timed switch-off
- Press the
button; the display will show the OFF symbol blinking alongside the temperature.
- Press the
button again; the display will show two blinking digits indicating the number of hours (h) to set.
- Using the
button, select the desired number of hours (from 1 to 99) and then press the
button to confirm.
The timer-thermostat will then stay off for a set period of time after which it will switch on going into the prior operating mode (manual or automatic).
Antifreeze
- Press the
button; the display will show the OFF symbol blinking alongside the temperature.
- Press the
button again; the display will show two blinking digits to set if you want timed switch-off for the device.
- Press the
button a third time; the display will show 3 blinking digits indicating the antifreeze temperature to set (from 04.0 °C to 15 °C).
- Using the
button, select the desired temperature and then press the
button to confirm.
With the heating system off, the display will show the antifreeze symbol next to the measured temperature.
Summer/winter selection
This type of function is only used when, besides the heating system, it is also necessary to control the air-conditioning system with the timer-thermostat.
- Press and hold down the
button; the display will show the
symbol or the symbol
.
- Using the
button, select the
symbol for the winter season and the
symbol for the summer and press the
button to confirm.
In air-conditioning operation (summer), the steps performed on the timer-thermostat are the opposite to the ones in heating operation (winter).
FOR THE INSTALLER.
For further information and for details on all the other timer-thermostat 01910 menus please refer to the installer manual that can be downloaded from the website www. vimar.com.
INSTALLATION RULES.
Installation should be carried out by qualified staff in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
REGULATORY COMPLIANCE.
- LV Directive. EMC Directive. Standards EN 60730-1, EN 60730-2-7, EN 60730-2-9.
- REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
INSTALLATION
FITTING/REPLACING POWER BATTERIES
ATTENTION! After replacing the battery, dispose of the old battery in the appropriate sorted refuse bins.
CONNECTIONS
Circulation pumps, burners, solenoid valves.
Motor-operated valves.
Phone dialler control.
C: Connection to a telephone actuator with clean contact
Viale Vicenza, 14
36063 Marostica VI – Italy
www.vimar.com
Documents / Resources
![]() |
VIMAR 01910 Electronic Timer Thermostat [pdf] Instruction Manual 01910, 01910 Electronic Timer Thermostat, Electronic Timer Thermostat, Timer Thermostat, Thermostat |