Vigor AP910C Ceiling Mounting Process

Specifications
- Color temperature settings: C = 5000K
- Color temperature settings: P = 4000K
- Color temperature settings: W = 2800K
- IP rating note: IP40 lamps cannot be used outdoors
- Dimming: Not dimmable
- Light source: Not replaceable (replace entire luminaire at end of life or if connection compartment is damaged)
Quick Guide
- Disconnect power before starting installation work (remove fuse or switch off at the grid to OFF).
- Ensure the wiring is correctly matched: N = Blue (Neutral), L = Brown/Black (Phase/Hot).
- Use a fixation system designed to support the actual weight of the lamp.
- Route wiring and connections away from heat sources and make sure wiring is not damaged during drilling or fixing.
- Verify installation location meets safety requirements (not on flammable surfaces; not on damp, freshly painted, or electrically conductive surfaces).
- After installation, ensure the terminal compartment remains dry, and no moisture reaches live parts.
INSTALLATION INSTRUCTION

SAFETY INSTRUCTIONS
- Electrical appliances must only beconnected by qualified persons
- Important! Before starting installation work, disconnect the
- Disconnect the main cable from the power supply –remove the fuse or turn the switch off from the power grid – remove the fuse or turn off the switch.
- The lamps with an index of protection of 40 (IP40) cannot be used outdoors
- Lamps marked with the symbol may not be installed on e flammable surfaces such as carpet.
- Do not attach the lamp to damp surfaces, freshly painted, or otherwise electrically conductive.
- Connect the wires of the lamp with the same color likethe werden wires of the wall or the ceiling.N =blue=neutral wire.L=brown 6 (black) = phase.
- Use the fixation system according to the weight of the lamp.= Phase.
- Keep the wires and connections away from heat sources.
- Make sure that the wiring is not damaged during drilling/ Weight of the lamp fixing procedure.
- This product is not dimmable.
- Cleaning is limited to the outer surfaces. It is important to ensure that it is not damaged.
- Keep the appliance and its cord out of the reach of children. Make sure that no masture gets into it.
- The light source of this luminaire is not replaceable; the entire connection compartment is exposed, or parts that carry electricity are touched!
- The luminaire must be replaced.
RETAIN THESE DOCUMENTS FOR FUTURE REFERENCE CAREFULLY
EXPLANATION OF PROTECTION CLASSES:
Protection class II: This lamp is double insulated and must not be connected to the earth Wire.![]()
CUSTOMER SERVICE
- Please scan the QR code to access detailed instructions in your preferred language(s).

- Lionway Electronics Co., Limited 1506, 120 Minsheng Rd, Gongming St, Guangming Dist, Shenzhen, 518106, CN. (Ivl@lwl-led.com) www.perfect-ledlighting.com
- EC RIP Gräenberger Allee 277, 40237 Düsseldorf DE Info@apex-ce.com/ +49 21312066043
- UK REP О fice10132 Threadneedle Street, London, United Kingdom, EC2R8AY EVATOSTCONSULTINGLTD
- contact@evatost.com
- +44 2076494690
Troubleshooting
- If the luminaire’s light source has reached the end of its life or the connection compartment is damaged: the entire luminaire must be replaced.
- If you suspect unsafe moisture ingress or exposure to live parts: stop and ensure cleaning is limited to outer surfaces only, with no moisture entering the terminal compartment.
- If installation cannot proceed safely due to electrical connection uncertainty: have qualified persons perform the wiring; disconnect the main cable (fuse removal or grid switch OFF) before any work.