solis Eksport quvvat menejeri yordamida eksport chegarasi sozlamalari
O'RNATISH QADAMLARI
- 1-QADAM: EPM da Enter tugmasini bosing.
- 2-QADAM: Yuqoriga/pastga tugmalari yordamida “Kengaytirilgan sozlamalar” ga oʻting. Enter tugmasini bosing.
Parolni kiriting – <0010> va Ent tugmasini bosing.
Siz quyidagi variantlarni ko'rasiz. - 3-QADAM: “Invertor miqdori” opsiyasini tanlab, inverter miqdorini o‘rnating. Saqlash uchun Ent tugmasini bosing.
- 4-QADAM: "Orqaga oqim kuchi" ni tanlang va Enter tugmasini bosing.
Tepaga/pastga tugmalari yordamida sizning talabingizga ko'ra Orqa oqim kuchini aniqlang. Tanlash va saqlash uchun Enter tugmasini bosing. - 5-QADAM: CT nisbati parametrini aniqlash uchun 'Set Meter CT' ni tanlang. Misol uchunample, agar sizning CT clamp reyting 100A / 5A, keyin nisbat 20: 1 ga teng. Tanlash va saqlash uchun Enter tugmasini bosing.
- 6-QADAM: Chiqish uchun ESC tugmasini ikki marta bosing.
'HAMMASI BAJARILDI' KUN HAYRLI O'TSIN!
Web: www.solisinverters.com.au
Ph: 03 8555 9516
E: service@ginlongaust.com.au
Hujjatlar / manbalar
![]() |
solis Eksport quvvat menejeri yordamida eksport chegarasi sozlamalari [pdf] Ko'rsatmalar Eksport limiti sozlamalari, Eksport quvvat menejeridan foydalanish, Eksport quvvat menejeri yordamida eksport chegarasi sozlamalari |