EXPORT LIMIT SETTINGS

EXPORT LIMIT SETTINGS - Solis-inverters

STEP 3: Set the inverter quantity by selecting the 'Inverter Qty' option. Press Ent to save. STEP 4: Select 'Backflow Power' and Press Enter.


File Info : application/pdf, 2 Pages, 227.77KB

PDF preview unavailable. Download the PDF instead.

SOLIS-Export-Limit-Settings-Using-Export-Power-Manager-EPM
EXPORT LIMIT SETTINGS
Using Export Power Manager (EPM)

SETTING UP EXPORT LIMIT USING EXPORT POWER MANAGER (EPM)
STEP 1: Press Enter on the EPM. STEP 2: Scroll down to `Advanced Settings' using the Up/Down keys. Press Enter. Type the password - <0010> and click Ent. You will see the following options.
STEP 3: Set the inverter quantity by selecting the `Inverter Qty' option. Press Ent to save. STEP 4: Select `Backflow Power' and Press Enter. Define the Backflow power as per your requirement using the Up/Down keys. Press Enter to select and save. STEP 5: Select `Set Meter CT' to define the CT ratio parameter. For example, if your CT clamp rating is 100A/5A then the ratio is 20:1. Press Enter to select and save. STEP 6: Press ESC twice to exit.
`ALL DONE' HAVE A GOOD DAY!