  • The DSP-55 is a compact vehicle detector that will operate on any voltage from 8 to 35 volts DC. The low voltage range is ideal for solar applications.
  • The DSP-55 can be connected to a standard inductive loop or one of Diablo Controls mini-loops. The Diablo Controls mini-loop is a small “pipe shaped” device approximately 4-1/2” by 1” and is designed to be buried in the ground to detect vehicles.
  • The DSP-55 can be used as either a safety loop or free exit loop detector. It should not be used as a safety loop if used with a mini-loop. It also has the flexibility to be either “fail-safe” or “fail-secure”.
  • The DSP-55 has three solid-state FET outputs called A, B and -B outputs. The two B outputs are “normal” and “inverted”. These combinations of outputs allow for the DSP-55 to be easily interfaced to a wide variety of control boards.
  • The DSP-55 has 10 selectable sensitivity settings and uses a 10-position DIP switch to configure the detector. This includes delay or extension timing functions and pulse on entry or pulse on exit features.
  • This makes the DSP-55 very flexible and versatile for those installations that need a little more than a standard detector.
    Oʻzgartirish Funktsiya
    1 O'CHIRIB Norm ON 2 sek. Kechikish O'CHIRIB 2 Sec. Extend ON 5 Sec. Extend
    2 O'CHIRIB O'CHIRIB ON ON
    3 O'CHIRIB Muvaffaqiyatsiz ON Fail-Secure
    4 O'CHIRIB Oddiy sezuvchanlik ON Sezuvchanlikni oshirish
    5 O'CHIRIB B

    Pres

    ON B Entry Pulse O'CHIRIB B Exit Pulse ON B Fail Output
    6 O'CHIRIB O'CHIRIB ON ON
    7 O'CHIRIB Oddiy mavjudligi ON Kengaytirilgan mavjudlik
    8 O'CHIRIB Induktiv halqa ON Mini-loop
    9 O'CHIRIB Yuqori ON Med Oliy O'CHIRIB Med Low ON Past
    10 O'CHIRIB O'CHIRIB ON ON

Texnik xususiyatlari

  • Loop Inductance: Not specified
  • Ishlash harorati: ko'rsatilmagan
  • Operatsion jildtage: 8 volts to 35 volts DC
  • Operating Current: Without call is 31 mA maximum, With a call is 40 mA maximum
  • Output Ratings: Solid State Outputs: 250 milliamps @ 30 volt
  • Enclosure: Impact resistant plastic, 2.375 (H) x 0.86 (W) x 2.25 (D) inches / 60.4 mm (H) x 22 mm (W) x 58 mm (D)

Xususiyatlari 

  • Can be connected to a standard inductive loop as well as Diablo Controls mini-loops.
  • Kichik profile, perfect for many installations.
  • Three Solid State outputs.
  • Fail-safe or Fail-secure operation.
  • Wide low-voltage operatsiya
  • Separate Power/Fail and Detect LEDs.
  • B Outputs can be presence, pulse on entry, pulse on exit, or loop fail.
  • Flicker display shows occupancy of the detection zone when operating in a pulse mode.
  • Delay or extension time is possible.

Mahsulot haqida ma'lumot

The DSP-55 Loop and Mini-Loop Vehicle Detector is a compact vehicle detector that operates on a wide voltage range of 8 to 35 volts DC, making it suitable for various installations including solar applications. It can be connected to standard inductive loops or Diablo Controls mini-loops, offering flexibility in detectionmethods. The detector features three solid-state outputs, fail-safeor fail-secure operation modes, and separate Power/Fail and Detect  LEDs for easy monitoring.

O'rnatish

  1. Connect the DSP-55 to the desired loop configuration based on your installation requirements.
  2. Ensure proper power supply within the voltage range of 8 to 35 volts DC.

Konfiguratsiya

  1. Use the 10-position DIP switch to set sensitivity levels and customize delay or extension timings.
  2. Adjust the sensitivity switch to accommodate different loop sizes or mini-loops.

Chiqish sozlamalari

  1. Configure the solid-state outputs A, B, and -B based on your control board requirements.
  2. Output B can be set to presence, pulse on entry, pulse on exit, or loop fail modes.

Monitoring

  1. Monitor the operation using the Flicker display that shows occupancy of the detection zone in pulse mode.
  2. Use the separate LEDs for Power/Fail and Detect status indication.

TANLANISH XUSUSIYATLARI 

Sezuvchanlik kaliti:
This detector has a 10-position rotary sensitivity switch. The unit is shipped in the 5 position which is the normal sensitivity level. Sensitivity can be adjusted up or down from this level to accommodate different loop sizes or mini-loops.

Sozlama 0 1 2 3 4 5 6 7 8 9
%DL/L 0.48 0.32 0.24 0.16 0.12 0.08 0.06 0.04 0.03 0.02
Javob vaqti 70 ms ± 10 ms 140 ms ± 20 ms

Solid State Output A Control: Effects output A only.

1 2 Funktsiya
O'CHIRIB O'CHIRIB Output A has normal presence
ON O'CHIRIB Output A has 2 seconds of delay
O'CHIRIB ON Output A has 2 seconds of extension
ON ON Output A has 5 seconds of extension

Muvaffaqiyatsiz operatsiya:
In fail-safe, the detector will output a detect when the loop circuit is failed. In fail-secure, the detector will not output a detect when the loop circuit is failed. Set DIP switch 3 to off to operate in fail-safe mode. Set the switch to on to operate in fail-secure mode. Note: Never use a fail-secure detector for a safety loop.

3 Funktsiya
O'CHIRIB Chiqish A xato-xavfsiz rejimida ishlaydi
ON Chiqish A Fail-Secure rejimida ishlaydi

Sezuvchanlikni oshirish:
Set DIP switch 4 to off to operate with normal sensitivity. Set DIP switch 4 to on to automatically boost sensitivity during a call to improve detection of high-bed vehicles and truck/trailer combinations. Sensitivity boost is not applicable to most situations.

4 Funktsiya
O'CHIRIB Detector uses normal sensitivity
ON Detektor aniqlangandan keyin sezgirlikni oshiradi

Solid State Output B Control:
Effects output “B” only.

5 6 Funktsiya
O'CHIRIB O'CHIRIB B output is normal presence output
ON O'CHIRIB B output is an “Entry“ pulse
O'CHIRIB ON B output is an “Exit” pulse
ON ON B output is a “Fail” condition

Kengaytirilgan mavjudlik vaqti:
Set DIP switch 7 to off to hold a vehicle’s presence for about 60 minutes before tuning it out. Set the switch to on to hold it significantly longer, perhaps up to a few days.

7 Funktsiya
O'CHIRIB Normal detection hold time
ON Kengaytirilgan aniqlashni ushlab turish vaqti

SELECTABLE FEATURES (Continued) 

Loop turi:
Set DIP switch 8 to off to operate with a normal inductive loop. Set the switch to on to operate with a Diablo Controls mini-loop. The mini-loop mode will always be an entry pulse. As such, it is perfect for free exit operation. Never use the mini-loop as a safety loop.

8 Funktsiya
O'CHIRIB Oddiy induktiv halqa
ON Diablo Controls mini-loop

Chastotasi: Chastotani 9 va 10 kalitlari yordamida tanlash mumkin.

9 10 Funktsiya
O'CHIRIB O'CHIRIB Eng yuqori aylanish chastotasi
ON O'CHIRIB O'rtacha eng yuqori aylanish chastotasi
O'CHIRIB ON O'rtacha past aylanish chastotasi
ON ON Eng past aylanish chastotasi

INDIKATORLAR

Yashil quvvat LED:
The LED will be on steady to indicate the detector is powered and operating normally. If the LED is not on solid, it is indicating a current or prior fault.

Xato Joriy uchun ekran Oldingi uchun ko'rsatish
Kam hajmlitage 2% ish aylanishi bilan 50 Gts YO'Q
Loopni oching 1 flash ON every 2s 1 flash OFF every 2s
Qisqartirilgan halqa Har 2 soniyada 2 marta yonadi Har 2 soniyada 2 ta miltillovchi O'CHIRILGAN
Katta o'zgarish Har 3 soniyada 2 marta yonadi Har 3 soniyada 2 ta miltillovchi O'CHIRILGAN

Red Detect A LED:
Avtomobil halqani aniqlash maydonidan oshib ketganda LED yonadi. Agar kechikish dasturlashtirilgan bo'lsa, LED kechikish oralig'ida sekin miltillaydi. Agar kengaytma dasturlashtirilgan bo'lsa, LED kengaytma oralig'ida tez miltillaydi.

Red Detect B LED:
The LED will turn on when the output B is active. If a pulse mode is selected, the LED will flicker while a vehicle is in the detection zone and the output is inactive.

ULANGAN PINLAR

DIABLO-CONTROLS-DSP-55-Loop-and-Mini-Loop-Vehicle-Detector-FIG-

www.LinearGateOpeners.com
800-878-7829
Sales@LinearGateOpeners.com

Tez-tez so'raladigan savollar

Q: Can the DSP-55 be used with solar-powered systems?
A: Yes, the DSP-55 operates on a low voltage range ideal for solar applications.

Q: How many solid-state outputs does the DSP-55 have?
A: The DSP-55 has three solid-state FET outputs named A, B, and -B.

Q: What are the different functions of the sensitivity switch?
A: The sensitivity switch offers 10 selectable settings to adjust sensitivity levels for different loop sizes or mini-loops.