DIABLO CONTROLS DSP-55 Loop and Mini Loop Vehicle Detector
Loop and Mini-Loop Vehicle Detector
- The DSP-55 is a compact vehicle detector that will operate on any voltage from 8 to 35 volts DC. The low voltage range is ideal for solar applications.
- The DSP-55 can be connected to a standard inductive loop or one of Diablo Controls mini-loops. The Diablo Controls mini-loop is a small “pipe shaped” device approximately 4-1/2” by 1” and is designed to be buried in the ground to detect vehicles.
- The DSP-55 can be used as either a safety loop or free exit loop detector. It should not be used as a safety loop if used with a mini-loop. It also has the flexibility to be either “fail-safe” or “fail-secure”.
- The DSP-55 has three solid-state FET outputs called A, B and -B outputs. The two B outputs are “normal” and “inverted”. These combinations of outputs allow for the DSP-55 to be easily interfaced to a wide variety of control boards.
- The DSP-55 has 10 selectable sensitivity settings and uses a 10-position DIP switch to configure the detector. This includes delay or extension timing functions and pulse on entry or pulse on exit features.
- This makes the DSP-55 very flexible and versatile for those installations that need a little more than a standard detector.
Oʻzgartirish Funktsiya 1 O'CHIRIB Norm ON 2 sek. Kechikish O'CHIRIB 2 Sec. Extend ON 5 Sec. Extend 2 O'CHIRIB O'CHIRIB ON ON 3 O'CHIRIB Muvaffaqiyatsiz ON Fail-Secure 4 O'CHIRIB Oddiy sezuvchanlik ON Sezuvchanlikni oshirish 5 O'CHIRIB B Pres
ON B Entry Pulse O'CHIRIB B Exit Pulse ON B Fail Output 6 O'CHIRIB O'CHIRIB ON ON 7 O'CHIRIB Oddiy mavjudligi ON Kengaytirilgan mavjudlik 8 O'CHIRIB Induktiv halqa ON Mini-loop 9 O'CHIRIB Yuqori ON Med Oliy O'CHIRIB Med Low ON Past 10 O'CHIRIB O'CHIRIB ON ON
Texnik xususiyatlari
- Loop Inductance: Not specified
- Ishlash harorati: ko'rsatilmagan
- Operatsion jildtage: 8 volts to 35 volts DC
- Operating Current: Without call is 31 mA maximum, With a call is 40 mA maximum
- Output Ratings: Solid State Outputs: 250 milliamps @ 30 volt
- Enclosure: Impact resistant plastic, 2.375 (H) x 0.86 (W) x 2.25 (D) inches / 60.4 mm (H) x 22 mm (W) x 58 mm (D)
Xususiyatlari
- Can be connected to a standard inductive loop as well as Diablo Controls mini-loops.
- Kichik profile, perfect for many installations.
- Three Solid State outputs.
- Fail-safe or Fail-secure operation.
- Wide low-voltage operatsiya
- Separate Power/Fail and Detect LEDs.
- B Outputs can be presence, pulse on entry, pulse on exit, or loop fail.
- Flicker display shows occupancy of the detection zone when operating in a pulse mode.
- Delay or extension time is possible.
Mahsulot haqida ma'lumot
The DSP-55 Loop and Mini-Loop Vehicle Detector is a compact vehicle detector that operates on a wide voltage range of 8 to 35 volts DC, making it suitable for various installations including solar applications. It can be connected to standard inductive loops or Diablo Controls mini-loops, offering flexibility in detectionmethods. The detector features three solid-state outputs, fail-safeor fail-secure operation modes, and separate Power/Fail and Detect LEDs for easy monitoring.
O'rnatish
- Connect the DSP-55 to the desired loop configuration based on your installation requirements.
- Ensure proper power supply within the voltage range of 8 to 35 volts DC.
Konfiguratsiya
- Use the 10-position DIP switch to set sensitivity levels and customize delay or extension timings.
- Adjust the sensitivity switch to accommodate different loop sizes or mini-loops.
Chiqish sozlamalari
- Configure the solid-state outputs A, B, and -B based on your control board requirements.
- Output B can be set to presence, pulse on entry, pulse on exit, or loop fail modes.
Monitoring
- Monitor the operation using the Flicker display that shows occupancy of the detection zone in pulse mode.
- Use the separate LEDs for Power/Fail and Detect status indication.
TANLANISH XUSUSIYATLARI
Sezuvchanlik kaliti:
This detector has a 10-position rotary sensitivity switch. The unit is shipped in the 5 position which is the normal sensitivity level. Sensitivity can be adjusted up or down from this level to accommodate different loop sizes or mini-loops.
Sozlama | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
%DL/L | 0.48 | 0.32 | 0.24 | 0.16 | 0.12 | 0.08 | 0.06 | 0.04 | 0.03 | 0.02 |
Javob vaqti | 70 ms ± 10 ms | 140 ms ± 20 ms |
Solid State Output A Control: Effects output A only.
1 | 2 | Funktsiya |
O'CHIRIB | O'CHIRIB | Output A has normal presence |
ON | O'CHIRIB | Output A has 2 seconds of delay |
O'CHIRIB | ON | Output A has 2 seconds of extension |
ON | ON | Output A has 5 seconds of extension |
Muvaffaqiyatsiz operatsiya:
In fail-safe, the detector will output a detect when the loop circuit is failed. In fail-secure, the detector will not output a detect when the loop circuit is failed. Set DIP switch 3 to off to operate in fail-safe mode. Set the switch to on to operate in fail-secure mode. Note: Never use a fail-secure detector for a safety loop.
3 | Funktsiya |
O'CHIRIB | Chiqish A xato-xavfsiz rejimida ishlaydi |
ON | Chiqish A Fail-Secure rejimida ishlaydi |
Sezuvchanlikni oshirish:
Set DIP switch 4 to off to operate with normal sensitivity. Set DIP switch 4 to on to automatically boost sensitivity during a call to improve detection of high-bed vehicles and truck/trailer combinations. Sensitivity boost is not applicable to most situations.
4 | Funktsiya |
O'CHIRIB | Detector uses normal sensitivity |
ON | Detektor aniqlangandan keyin sezgirlikni oshiradi |
Solid State Output B Control:
Effects output “B” only.
5 | 6 | Funktsiya |
O'CHIRIB | O'CHIRIB | B output is normal presence output |
ON | O'CHIRIB | B output is an “Entry“ pulse |
O'CHIRIB | ON | B output is an “Exit” pulse |
ON | ON | B output is a “Fail” condition |
Kengaytirilgan mavjudlik vaqti:
Set DIP switch 7 to off to hold a vehicle’s presence for about 60 minutes before tuning it out. Set the switch to on to hold it significantly longer, perhaps up to a few days.
7 | Funktsiya |
O'CHIRIB | Normal detection hold time |
ON | Kengaytirilgan aniqlashni ushlab turish vaqti |
SELECTABLE FEATURES (Continued)
Loop turi:
Set DIP switch 8 to off to operate with a normal inductive loop. Set the switch to on to operate with a Diablo Controls mini-loop. The mini-loop mode will always be an entry pulse. As such, it is perfect for free exit operation. Never use the mini-loop as a safety loop.
8 | Funktsiya |
O'CHIRIB | Oddiy induktiv halqa |
ON | Diablo Controls mini-loop |
Chastotasi: Chastotani 9 va 10 kalitlari yordamida tanlash mumkin.
9 | 10 | Funktsiya |
O'CHIRIB | O'CHIRIB | Eng yuqori aylanish chastotasi |
ON | O'CHIRIB | O'rtacha eng yuqori aylanish chastotasi |
O'CHIRIB | ON | O'rtacha past aylanish chastotasi |
ON | ON | Eng past aylanish chastotasi |
INDIKATORLAR
Yashil quvvat LED:
The LED will be on steady to indicate the detector is powered and operating normally. If the LED is not on solid, it is indicating a current or prior fault.
Xato | Joriy uchun ekran | Oldingi uchun ko'rsatish |
Kam hajmlitage | 2% ish aylanishi bilan 50 Gts | YO'Q |
Loopni oching | 1 flash ON every 2s | 1 flash OFF every 2s |
Qisqartirilgan halqa | Har 2 soniyada 2 marta yonadi | Har 2 soniyada 2 ta miltillovchi O'CHIRILGAN |
Katta o'zgarish | Har 3 soniyada 2 marta yonadi | Har 3 soniyada 2 ta miltillovchi O'CHIRILGAN |
Red Detect A LED:
Avtomobil halqani aniqlash maydonidan oshib ketganda LED yonadi. Agar kechikish dasturlashtirilgan bo'lsa, LED kechikish oralig'ida sekin miltillaydi. Agar kengaytma dasturlashtirilgan bo'lsa, LED kengaytma oralig'ida tez miltillaydi.
Red Detect B LED:
The LED will turn on when the output B is active. If a pulse mode is selected, the LED will flicker while a vehicle is in the detection zone and the output is inactive.
ULANGAN PINLAR
www.LinearGateOpeners.com
800-878-7829
Sales@LinearGateOpeners.com
Tez-tez so'raladigan savollar
Q: Can the DSP-55 be used with solar-powered systems?
A: Yes, the DSP-55 operates on a low voltage range ideal for solar applications.
Q: How many solid-state outputs does the DSP-55 have?
A: The DSP-55 has three solid-state FET outputs named A, B, and -B.
Q: What are the different functions of the sensitivity switch?
A: The sensitivity switch offers 10 selectable settings to adjust sensitivity levels for different loop sizes or mini-loops.
Hujjatlar / manbalar
![]() |
DIABLO CONTROLS DSP-55 Loop and Mini Loop Vehicle Detector [pdf] Foydalanuvchi qo'llanmasi DSP-55 Loop and Mini Loop Vehicle Detector, DSP-55, Loop and Mini Loop Vehicle Detector, Mini Loop Vehicle Detector, Loop Vehicle Detector, Vehicle Detector |