TRAMEX logoCONCRETE
MOISTURE PROBE
‘THE DETERMINATOR’TRAMEX CMP Concrete Moisture Probe Determinator– CMP –
QUICK START GUIDE

GENERAL

  • The Determinator and CME5, CMEX5 (or older Tramex Concrete Meters CME4 and CMEX2) allow for a unified gravimetric-based testing method of moisture content (%MC) both on the surface and within the body of the concrete.
  • %MC readings for both the in-situ and the non-destructive surface tests eliminate confusion between different testing method data.
  • The Determinator conductive probes are reusable, extendable, and require no plastic hole liners.
  • The hole diameter required (¾”, 19mm) is the same for the Hygro-i2 RH test as per F2170.

ASSEMBLY

  • The Concrete Moisture Probe consists of a cradle, a probe tip and two extension segments.
  • Choose to use the extension segment(s), or not, depending on the depth of the slab. The probe should be inserted to approximately 40% of the depth of the slab.

TRAMEX CMP Concrete Moisture Probe Determinator - ASSEMBLY

OPERATION

Probe Testing:

  • Determine the approximate depth of the concrete slab.
  • Connect extension segment(s) to appropriate depth:
  • Concrete between 2″ to 4″ in depth shall require approximately 1 1/4″ of probe depth.
  • Concrete between 4” to 6” in depth shall require approximately 2 1/4” of probe depth.
  • Concrete between 6” to 9” in depth shall require approximately 3 1/4” of probe depth.
  • Concrete between 9″ to 11″ in depth shall require approximately 4 1/4″ of probe depth.
    * The probe should be inserted to approximately 40% of the depth of the slab.
    * Similar to ASTM F2170 Recommendations for frequency of use: 3 Tests per 1,000 sq.ft. and 1 additional test for every additional 1,000 sq.ft. or partition thereof.
  • Insert the Concrete Moisture Probe into the hole so that the cradle is flat on the surface.

TRAMEX CMP Concrete Moisture Probe Determinator - Probe Testing

OPERATION

  • Place your Tramex Concrete meter into the cradle of the CMP and ensure that all of the electrode spring-loaded pins are fully compressed, both on the CMP and the CME.
  • Take 4 readings by turning the Concrete Moisture Probe and CME meter from ‘12 o’clock’ to 3, 6 and 9 o’clock positions. Record the highest reading, discarding any obvious anomalies.
  • Record the readings using the Tramex Meters App (when using the CME5 or CMEX5).

USER GUIDE ONLINE

TRAMEX CMP Concrete Moisture Probe Determinator - QR code

Free App Available for Mobile and Tablet:

TRAMEX CMP Concrete Moisture Probe Determinator - SymbolLI-CMPQSG

TRAMEX logoTRAMEX CMP Concrete Moisture Probe Determinator - logo 2Distributed by: ABQ Industrial LP USA
Tel: +1 281-516-9292 / 888-275-5772
eFax: +1 866-234-0451
Web: https://www.abqindustrial.net
E-mail: info@abqindustrial.net

Documents / Resources

TRAMEX CMP Concrete Moisture Probe Determinator [pdf] User Guide
CMP, CMP Concrete Moisture Probe Determinator, CMP Determinator, Concrete Moisture Probe Determinator, Concrete Moisture Probe, Moisture Probe, Determinator, Concrete Probe, Probe

References

Leave a comment

Your email address will not be published. Required fields are marked *