LEDPROSL2B PIR Sensor for LEDPRO Floodlights Black
“
Specifications:
- Product Name: LEDPRO PIR Sensor
- Available Colors: Black, White
- IP Rating: IP65
Product Usage Instructions:
Safety Instructions:
- Read and retain the instructions for future reference.
- Isolate mains power before installation or maintenance.
- Ensure total load on the circuit does not exceed ratings.
- Consider IP rating for installation location.
- Product is IP65 rated.
- Installation must comply with IEE Wiring Regulations and
Building Regulations.
Environmental Instructions:
Dispose of product properly to avoid environmental hazards.
Recycle packaging where possible.
Installation Instructions:
SUGGESTED METHOD OF INSTALLATION:
1. Read instructions and gather necessary tools.
SENSOR SETTINGS:
1. Use a small flat headed screwdriver to adjust dials.
2. Remove junction box and compression glands from
luminaire.
3. Attach compression glands to sensor junction box and feed
supply cable through glands.
4. Connect additional luminaires using slave terminal (up to
200W).
5. Detach jumper plug, replace with plug connected to PIR.
6. Secure sensor junction box with provided screws for IP rating
maintenance.
7. Tighten compression gland(s) and locknut for IP rating
maintenance.
Timer:
– Set timer from 2 seconds to 15 minutes or switch to photocell
mode.
Sensitivity:
– Default setting is High (up to 12m) adjustable to Low (up to
4m).
Lux:
– Set lux level from 20 Lux to 1000 Lux with moon symbol as
lowest and sun as highest.
Sensor Lens Masking:
To reduce sensor coverage, use lens mask sticker to cover
specific areas for detection.
Lux Learn Mode:
– Set sensor to activate at a specific darkness level by
adjusting the knob accordingly.
FAQ:
Q: How do I adjust the timer on the PIR sensor?
A: The timer can be adjusted from 2 seconds to 15 minutes or
switched to ‘D’ mode for photocell operation.
Q: What is the default sensitivity setting of the PIR
sensor?
A: The default sensitivity setting is High (up to 12m) and can
be adjusted to Low (up to 4m).
Q: How can I reduce unwanted detection areas of the
sensor?
A: You can use the lens mask sticker provided to mask specific
areas of the sensor lens.
“`
LEDPROSL2B
PIR Sensor for LEDPRO Floodlights Black
LEDPROSL2WH
PIR Sensor for LEDPRO Floodlight White
LEDPRO II PIR Sensor
Features
· IP65 rating for total protection against dust and low-pressure jets of water from any direction. · 3-year guarantee.
Safety Instructions
1. These instructions should be read carefully and retained after installation for future reference and maintenance. 2. Ensure that the mains power is isolated before carrying out installation or maintenance. 3. Check that the total load on the circuit including this luminaire does not exceed the rating of the circuit cable, fuse or
circuit breaker. 4. Please note the IP (Ingress Protection) rating of this product when deciding the location for installation.
5. This product is IP65 rated.
6. This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician.
Environmental Instructions
This product may contain substances that can be hazardous to the environment if not disposed of properly. Electrical and electronic equipment should never be disposed of with general household waste but must be separated for its correct treatment and recovery. Where possible recycle your packaging.
Installation Instructions
SUGGESTED METHOD OF INSTALLATION Read instructions and check you have all the tools and accessories to complete the installation safely and in compliance with current electrical standards.
SENSOR SETTINGS A small flat headed screwdriver is required to adjust the dials.
1. Remove the junction box and compression glands from the rear of the luminaire.
2. Attach the compression glands to the sensor junction box the feed the supply cable through the glands
3. Terminate the mains supply cable ensuring correct polarity is observed: Brown Live, Blue Neutral, Green/Yellow Earth.
L 4. There is a slave terminal ( ) to connect and control an
additional luminaires up to 200W. 5. Detach the jumper plug by pressing the locking bar and
pull to release (push to connect) replace with the plug connected to the PIR (see Fig.1)
Fig. 1
6. Secure the sensor junction box using the two screws provided ensuring a tight seal is made to maintain the IP rating.
7. Tighten the compression gland(s) and locknut ensuring tight seal is made to maintain the IP rating.
Fig. 3
Timer The timer can be set from 2 seconds to 15 minutes or switched to `D’ mode which puts the timer into photocell mode from dusk to where the lux levels are set at dawn.
Sensitivity The default setting is set to H (High up to 12m) and can be adjusted to L (low to 4m)
Lux The lux light level can be set from 20 Lux to 1000 Lux with the moon symbol being the lowest level and the sun is the highest
INS 0947 V1.0 01/25 NPD 0952
Deta Electrical Company Limited UK: Panattoni Park Luton Road Chalton Bedfordshire LU4 9TT EU: Unit 16 Ashbourne Ind. Est. Ashbourne Co. Meath A84 W972 Ireland deta.co.uk
Technical Helpline: +44(0)1582 544 548
Sensor Lens Masking To reduce the sensor coverage, preventing detection in unwanted areas, mask the sensor lens using the lens mask sticker supplied (see Fig. 2) The top section of the lens covers long range detection, the bottom covers short range. Similarly the left and right lens sections cover the left and right detection area respectively.
Lux Learn mode: The sensor can be set to come on at a different level of darkness, for example when it is a little lighter outside, then simply turn the knob to “Eye” symbol and it will remember the current light level and become active at this light level from now on.
Walk Test Procedure To start walk test, set the Time indicator to “2s” and Lux indicator to “Sun”. The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 2 seconds each time. This allows testing to be carried out to establish the best position for the sensor. The lamp will immediately illuminate as the unit goes through its warm-up period. After approximately 45 seconds the lamp will extinguish. Try to remain outside the detection area during the warm-up period.
Manual Override To activate the manual override switch, switch the light OFF/ON once within 2 seconds and the light will remain on for six hours or until switched back into sensor mode by switching OFF/ON again.
Fig. 2
Maintenance Instructions
· There are no serviceable parts in this fitting. · Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not use
aggressive cleaning products or solvents which may damage the product.. · Do not use any source of high-pressure washers to maintain or clean this luminaire · This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities for
where facilities exist.
Specification Input Voltage Time on Duration IP Rating Maximum load
230VAC 50Hz 2 seconds to 15 minutes IP65 Halogen – 200W CFL – 200W Fluorescent 200W LED (PF>0.9) 200W
Detection Angle Detection Range Linkable Lux Levels
180° 4 to 12M Yes up to 200W Lux learn mode, Day & Night 20-1000Lux or Night time only operation