OutWard™
Operating Instructions
OutWard Instant Read Thermometer
- Accuracy to ±0.9°F (±0.5°C)
- 2-3 second readings
- –58 to 572°F range
- Calibration trim
- NIST-traceable certificate
- 180° auto-rotating display
- IP67 rating
- Backlight
- °C/°F switchable
Instrument Operation
Press the power button to activate the thermometer. Temperatures will be displayed and the display will auto-rotate depending on orientation. The thermometer will turn off automatically after 10 minutes. This can be disabled. Press and hold the power button for 3 seconds to turn off. To activate the backlight, press the power button once while the instrument is turned on. Press again to turn off.Insert the stainless steel probe to the desired depth. The measured temperature will be shown on the LCD display within 2-3 seconds.
Auto-Off
To disable: Press button times. Display will flash OFF twice
To enable: Press button times. Display will flash ON twice.
Auto-off setting is saved even if instrument is turned off.Replace the battery when low battery symbol ‘Bat’ flashes.
Replace with a 3-volt, type CR2032, button-cell battery or equivalent.
Use a screwdriver of suitable size to open the battery cover on the back.
Install the battery observing the correct polarity, (+) positive side up, sliding the battery under the metal clip. Close the battery cover. To Select ˚F or ˚C
Press the °C/°F button on the back of the thermometer to select the desired temperature unit.
Calibration Trim
From the factory OutWard should read within ±0.9°F and a calibration adjustment should never be needed. For instructions on how and when to perform a one-point calibration trim go to www.thermoworks.com/outward.
Specifications
Measuring Range | –58 to 572°F (–50 to 300°C) |
Accuracy | ±0.9°F (±0.5°C) between 14 to 212°F (–10 to 100°C) ±4.5°F (±2.5°C) between 392 to 572°F (200 to 300°C); otherwise ±2.7°F (±1.5°C) |
Display Resolution | 0.1° over full range |
Response | 2 to 3 seconds |
IP Rating | IP67 |
Operating Range | 32 to 122°F (0 to 50°C) |
Probe | 4.5 L x 0.09 inch dia. reduces to 0.06 inches dia. (114 L x 2.5 mm dia. reduces to 1.6 mm dia.) |
Auto-Off | After 10 minutes, can be disabled |
Backlight | 10 seconds |
Battery | CR2032 (3V) lithium coin cell (included) x 1, 5,000 hours |
Display | 0.70 H x 1.3 W inches (18 H x 33 W mm); Digits: 0.6 H inches (15 H mm) |
Product Size | 2.7 W x 1.2 H x 1.02 D inches (70 W x 31 H x 26 D mm) |
Care and Cleaning
Clean the probe immediately after each measurement to avoid cross contamination. Do not expose the thermometer body to temperatures over 122°F (50°C). Do not leave inside ovens.
Avoid submersing the entire thermometer.
Technical Support
For warranty, service, and technical assistance, please contact ThermoWorks’ Technical Support at 801-756-7705 or email at techsupport@thermoworks.com.
For additional cooking tips and doneness temperatures, and to see the full line of ThermoWorks tools, visit our website at www.thermoworks.com.
Chef-Recommended Temps
For additional temperature recommendations, go to blog.thermoworks.com
Beef, Veal & Lamb Roasts, Steaks & Chops |
Rare 120-130°F* 49-54°C |
Med. Rare 130-135°F* 54-57°C |
Medium 135-145°F* 57-63°C |
Med. Well 145-155°F* 63-68°C |
Well Done 155°F-up* 68°C-up |
Pork Roasts, Steaks & Chops |
USDA-Done 145°F* 63°C |
Well Done 150°F-up* 66°C-up |
|||
BBQ Brisket, Ribs, & Pork Butt |
Done 190-205°F 88-96°C |
* These temperatures are ideal peak temperatures. Meats should be removed from heat several degrees lower and allowed to rise during resting.
** Chef-recommended temperatures are consistent with many expert sources for taste and safety. USDA-recommended temperatures are 5 to 10°F (2 to 5°C) higher.
Minimum Done Temps for Food Safety
Ground Meat: Beef, Veal, & Sausage* | 160°F (71°C) |
Ham (raw) | 160°F (71°C) |
Ham (pre-cooked) | 140°F (60°C) |
Egg dishes | 160°F (71°C) |
Casseroles & Leftovers | 165°F (74°C) |
Chicken, Turkey & Duck (whole or pieces)* | 165°F (74°C) |
Poultry Dark Meat** | 175°F (79°C) |
Stuffing (in the bird) | 165°F (74°C) |
Tuna, Swordfish & Marlin** | 125°F (52°C) |
Other Fish** | 140°F (60°C) |
Water Temps (at sea level)
Poach | 160-180°F (71-82°C) |
Low Simmer | 180°F (82°C) |
Simmer | 185°F (85°C) |
Slow Boil | 205°F (96°C) |
Rolling Boil | 212°F (100°C) |
Other Food Temps
Bread: Rich Dough | 190°F (88°C) |
Bread: Lean Dough | 200-210°F (93-99°C) |
Water temp to add active dry yeast | 105-115°F (41-46°C) |
Butter: Chilled | 35°F (2°C) |
Butter: Softened | 60-67°F (16-19°C) |
Butter: Melted & Cooled | 85-90°F (29-32°C) |
Candy or Sugar Syrup Temps (at sea level)
Thread | 230-234°F (110-112°C) | Syrup |
Soft Ball | 234-240°F (112-116°C) | Fondant, Fudge & Pralines |
Firm Ball | 244-248°F (118-120°C) | Caramels |
Hard Ball | 250-266°F (121-130°C) | Divinity & Nougat |
Soft Crack | 270-290°F (132-143°C) | Taffy |
Hard Crack | 300-310°F (149-154°C) | Brittles, Lollipops & Hardtack |
Caramel | 320-350°F (160-177°C) | Flan & Caramel Cages |
www.thermoworks.com
741 E. Utah Valley Dr.
American Fork, UT 84003
For service or warranty:
1-800-393-6434
1-801-756-7705
techsupport@thermoworks.com
P-23-003-02-b
Documents / Resources
![]() |
ThermoWorks OutWard Instant Read Thermometer [pdf] Instruction Manual OutWard Instant Read Thermometer, Instant Read Thermometer, Read Thermometer, Thermometer |