Televic 2025-0507 CamConnect Processor
Product Specifications
- Manufacturer: Variscite LTD
- Model: D-Cerno AE
- Maximum Microphones Supported: 17
- Minimum Distance Between Microphones: 1m
- Firmware Version: 1.4.0 -17
Product Usage Instructions
Discovering D-Cerno AE’s IP:
The Manufacturer’s name of D-Cerno AE will be shown as Variscite LTD. Use a tool like Advanced IP Scanner to scan for the device’s IP in your network. For example, D-Cerno AE’s IP is 192.168.0.221.
D-Cerno AE as Technician and Mode Selection:
- Enter D-Cerno AE’s IP address in a web browser.
- Access its configuration as a Technician.
- Navigate to the [Discussion] section and select a preferred mode, such as [Hands free] mode.
- Click on the mode until it turns green.
D-Cerno AE Key/Token for Camconnect Session:
Navigate to [Settings] > [API Settings & Type] to generate the token for the Camconnect session.
D-Cerno AE Connection with Camconnect:
- Copy and paste the generated token in Camconnect’s [API Access Key] field.
- In Camconnect’s web browser, enter D-Cerno AE’s IP address.
- Paste the API key as shown in the previous step.
- Configure other settings like time to trigger and back to home as desired.
- Hit Apply then toggle the Connect button to the right.
Overview
- Discovering D-Cerno AE`s IP.
- D-Cerno AE as Technician and mode selection.
- D-Cerno AE Key/Token for Camconnect session.
- D-Cerno AE connection with Camconnect.
- Camconnect and D-Cerno AE- Camera mapping and demo.
- Others
INSTALLATION
Discovering D-Cerno AE`s IP.
- The Manufacturer`s name of D-Cerno AE will be shown as Variscite LTD.
- Use any tool to scan for this device`s IP in your Network.
Ex. Advanced IP Scanner resolves. (Dcerno AE`s IP = 192.168.0.221)
D-Cerno AE as Technician and mode selection.
- Enter D-Cerno AE`s IP address in a web browser.
- Access its configuration as Technician;
- Navigate to [Discussion] section and select a preferred mode.
- In this example, [Hands free] mode is shown.
- Click on mode until it turns green.
D-Cerno AE Key/Token for Camconnect session
- Navigate to [settings] → [API Settings & Type].
D-Cerno AE connection with Camconnect
- Copy and paste the generated token in Camconnect`s [API Access Key] field.
In Camconnect`s web browser; (as shown below)
- Enter D-Cerno AE`s IP address.
- Paste API key as shown in previous slide.
- Make other settings like; time to trigger and back to home as you wish.
- Hit Apply then toggle the Connect button to the right.
Camconnect and D-Cerno AE- Camera mapping and demo.
- Map camera presets per D-Cerno C & D SL units/seats.
- In my example; 2 cameras and 3 seats are assigned in hands free mode.
- Below image shows; Seat 1 talker triggers camera TR60A preset 1:
Others
- In hands free mode, a maximum of 17 microphones is supported.
- Do not place microphones less than 1m apart from each other.
- Update your D-Cerno AE, D & C SL to latest firmware (ex. 1.4.0 -17).
- Read carefully the D- Cerno AE`s installation manual, especially the sections;
[installation], [Technician] and [operator and chairperson]. This ensures a seamless operation with Camconnect or have a certified Televic D-Cerno AE personel setup the room and then integrate with Camconnect. - Contact Lumens for technical support if any of above guide is unclear.
Thank You!
MyLumens.com
Contact Lumens
Copyright © Lumens. All rights reserved.
Frequently Asked Questions
Q: How many microphones does the D-Cerno AE support in hands-free mode?
A: The D-Cerno AE supports a maximum of 17 microphones in hands-free mode.
Q: What is the minimum distance recommended between microphones?
A: It is recommended not to place microphones less than 1m apart from each other.
Q: How can I update the firmware of my D-Cerno AE?
A: You can update your D-Cerno AE, D & C SL to the latest firmware version (e.g., 1.4.0 -17) by following the instructions provided in the firmware update guide.
Documents / Resources
![]() |
Televic 2025-0507 CamConnect Processor [pdf] User Guide 2025-0507, 2025-0507 CamConnect Processor, CamConnect Processor, Processor |