The R-S2 room regulator is equipped with a temperature and air humidity sensor.
Additionally, a floor sensor can be connected to the regulator. Current measurements are displayed on the device and sent to the Sinum Central device, where they can be freely used to create various automations. Communication with the Sinum Central device, is done by wire. The regulator is mounted to an electrical box with a diameter of 60 mm.

Opis

  1. Registration button
  2. Main button
  3. Navigation buttons
  4. SBUS communication connector
  5. Terminating resistor

How to register the device in the sinum system

The device should be connected to the Sinum central device using the SBUS connector TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 1 , and then enter the address of the Sinum central device in the browser and log in to the device. In the main panel, click the Settings > Devices > SBUS devices > TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 2> Add device. Then briefly press the registration button TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 3 on the device. After a properly completed registration process, an appropriate message will appear on the screen. Additionally, the user can name the device and assign it to a specific room. INFO: When registering the regulator, the humidity sensor and floor sensor (if it is connected) will also be registered automatically.

How to identify the device in the Sinum system

To identify the device in the Sinum Central, activate the Identification Mode in the Settings > Devices > SBUS Devices > TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 2> Identification Mode tab and hold the registration button on the device for 3-4 seconds. The device used will be highlighted on the screen.

Operation

  • Heating/cooling control * (icon TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 15 ) is possible after assigning the controller in the Sinum Central device to a virtual thermostat. On the display, the icon can have different meaning:
    – the icon is on permanently – heating of the room (heating mode)
    – the icon is blinking – room cooling (cooling mode)
    – no icon – no need for heating/cooling
  • Changing the preset temperature with the TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 4and TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 5 buttons and confirming with the Main button TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 6. The set temperature will be permanent. If the regulator is assigned to a virtual thermostat, after changing the temperature, use the TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 4andTECH Sinum R-S2 Tech Sterowniki Ii - Symbol 5 to specify the time range of the set temperature [0 ÷ 24h, Con (permanently) or Off (inactive change)], confirm with the Main button TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 6.
  • Button lock – pressing the Main button TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 6 will activate the function TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 7 ; use the TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 4orTECH Sinum R-S2 Tech Sterowniki Ii - Symbol 5 to select „yes” or „no” (automatic lock on/off). Confirm with the Main button or wait approx. 5 sec. Holding TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 4andTECH Sinum R-S2 Tech Sterowniki Ii - Symbol 5 simultaneously until the padlock icon disappears unlocks the buttons.
  • Controller connection – the system has a terminating connection. The position of the regulator on the transmission line with the Sinum Central is determined by the position of the terminating switch TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 8 . Set to ON position (regulator at the end of the line) or position 1 (regulator in the middle of the line).
    * option available depending on the program version

Menu

Hold down the Main buttton TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 6 until appears TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 9 option. Change options with TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 4andTECH Sinum R-S2 Tech Sterowniki Ii - Symbol 5 ,confirm with Main button TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 6. Options available:
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 9 – temperature sensor calibration,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 7 – activation/deactivation of the button lock; to unlock, hold down the and buttons simultaneously for 3 seconds,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 10 – device registration,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 11 – software information ,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 12 – service menu,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 13 – factory reset,
TECH Sinum R-S2 Tech Sterowniki Ii - Symbol 14– exit from the Menu,

Technical data

Power supply 24V DC ±10%
Max. power consumption 0,2W
Operation temperature 5 ÷ 50°C

Notes

TECH Controllers is not responsible for any damages resulting from improper use of the system. The manufacturer reserves the right to improve devices, update software and related documentation. The graphics are provided for illustration purposes only and may differ slightly from the actual look. The diagrams serve as examples. All changes are updated on an ongoing basis on the manufacturer’s website.
Before using the device for the first time, read the following regulations carefully. Not obeying these instructions may lead to personal injuries or controller damage. The device should be installed by a qualified person. It is not intended to be operated by children.
It is a live electrical device. Make sure the device is disconnected from the mains before performing any activities involving the power supply (plugging cables, installing the device etc.). The device is not water resistant.
The product may not be disposed of to household waste containers.
The user is obliged to transfer their used equipment to a collection point where all electric and electronic components will be recycled.

EU Declaration of conformity

Tech Sterowniki II Sp. z o.o. , ul. Biała Droga 34, Wieprz (34-122)
Hereby, we declare under our sole responsibility that the room regulator R-S2 is compliant with Directive :

  • 2014/35/UE
  • 2014/30/UE
  • 2009/125/WE
  • 2017/2102/UE

For compliance assessment, harmonized standards were used:

  • PN-EN IEC 60730-2-9:2019-06
  • PN-EN 60730-1:2016-10
  • EN IEC 63000:2018 RoHS

Wieprz, 01.12.2023

TECH Sinum R-S2 Tech Sterowniki Ii - Sigsar
The full text of the EU declaration of conformity and the user manual are available after scanning the QR code or at www.tech-controllers.com/manuals

TECH Sinum R-S2 Tech Sterowniki Ii - SymbolTECH STEROWNIKI II Sp. z o.o.
ul. Biała Droga 31
34-122 Wieprz

TECH Sinum R-S2 Tech Sterowniki Ii - QR Codwww.tech-controllers.com/manuals
Made in Poland

Documents / Resources

TECH Sinum R-S2 Tech Sterowniki Ii [pdf] Instruction Manual
R-S2 Tech Sterowniki Ii, R-S2, Tech Sterowniki Ii, Sterowniki Ii, Ii

References

Leave a comment

Your email address will not be published. Required fields are marked *