EJT1, EJT8 High Performance Power Inlet Filter
“
Specifications
- Current Rating: 1, 3, 6, 10, 15, or 20A
- Maximum Leakage Current:
- @ 120 VAC 60 Hz:
- 1-15A: 0.25 mA
- 20A: 0.22 mA
- @ 250 VAC 50 Hz:
- 1-15A: 0.43 mA
- 20A: 0.40 mA
- @ 120 VAC 60 Hz:
- Hipot Rating (One Minute): Line to Ground – 2250 VDC, Line to
Line – 1450 VDC - Rated Voltage (Max): 250 VAC
- Operating Frequency: 50/60 Hz
- Operating Ambient Temperature Range: The maximum operating
current (Io) is calculated as follows: Io = Ir (85-Ta)/45
Product Usage Instructions
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
FA601: Insulating Shroud (fits 1-15A only)
Available Part Numbers
1EJT1, 3EJT1, 6EJT1, 10EJT1, 15EJT1, 20EJT1
1EJT8, 3EJT8, 6EJT8, 10EJT8, 15EJT8, 20EJT8
Electrical Schematics
LINE – Case Styles EJT1 – LOAD
Case Dimensions
Part No. | A | B | C | D | E |
---|---|---|---|---|---|
EJT1 | EJT8 | 20EJT1 | 20EJT8 |
Recommended Panel Cutouts
1 to 15A: A – 1.575″, B – 1.20″, R – .062″ Max., Dia. –
.820″
20A: A – 1.654″, B – 1.370″, R – .062″ Max., Dia. – .820″
FAQ
Q: What is the maximum rated voltage for the product?
A: The maximum rated voltage is 250 VAC.
Q: What is the operating ambient temperature range?
A: The operating ambient temperature range is calculated using
the formula Io = Ir (85-Ta)/45.
Q: Are there any accessories available for this product?
A: Yes, accessories like GA400 and FA601 are available for this
product.
“`
Corcom Product Guide High Performance Power Inlet Filter
EJT Series
Catalog: 1654001 Issue Date: 06.2011
UL Recognized CSA Certified VDE Approved*
EJT1
EJT8
Power Inlet Filters & Power Entry Modules
EJT Series
· Superior EMI filter with IEC 60320-1 inlet · Double three element differential mode circuit
attenuates noise up to 1GHz · Up to 15A with IEC 60320-1 C14 inlet · 20A rating with IEC 60320-1 C20 inlet · Spade terminals or wire leads
Ordering Information 6 EJT 1
Output Styles 1 .250 [6.3] spade terminals 8 Wire leads
EJT Series
Current Rating 1, 3, 6, 10, 15 or 20A
Specifications
Maximum leakage current each Line to Ground:
1-15A
20A
@ 120 VAC 60 Hz:
.25 mA
.22 mA
@250 VAC 50 Hz:
.43 mA
.40 mA
Hipot rating (one minute): Line to Ground: Line to Line:
2250 VDC 1450 VDC
Rated Voltage (max.):
250 VAC
Operating Frequency:
50/60 Hz
Rated Current:
1 to 20A*
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
3
Available Part Numbers
1EJT1 3EJT1 6EJT1 10EJT1 15EJT1 20EJT1
1EJT8 3EJT8 6EJT8 10EJT8 15EJT8 20EJT8
FA601: Insulating Shroud (fits 1-15A only)
.413 10.5
Dia.
.271 6.9
Dia.
*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC.
20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC.
.118 3.0
1.39 35.4
1.17 29.7
.767 19.5
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
163
For email, phone or live chat, please go to
te.com/help
corcom.com
Downloaded from Arrow.com.
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
High Performance Power Inlet Filter (continued)
EJT Series
Electrical Schematics
LINE
Case Styles EJT1
LOAD
1 1
C
B D E
20EJT1
A
C
D E
EJT8
B
A
DE
Blue
Green/Yellow
B
Brown
A C
20EJT8
DE
Blue Green/Yellow
B
Brown
A
C
Case Dimensions
Part No.
A
B
EJT1 EJT8 20EJT1 20EJT8
C
D
E
Recommended Panel Cutouts
1 to 15A
1.575 40.00
1.20 30.48
20A
1.654 42.01 1.370 34.80
0.140 3.56
Dia.
.820 20.83
R
.062 1.57
Max.
0.138 3.51
Dia.
Front Mount Only Tolerance ±.005 [.13]
1.055 26.80
R
.062 1.57
Max.
164
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.
For email, phone or live chat, please go to te.com/help corcom.com
Corcom Product Guide
Catalog: 1654001 Issue Date: 06.2011
High Performance Power Inlet Filter (continued)
EJT Series
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
1EJT
3EJT
db 100
90
80
70
60
50
40
30
20
10
0
0.1
1
db 100
90
80
70
60
50
40
30
20
10
0
10
100
1000
0.1
1
Frequency in MHz
6EJT
db 100
90
80
70
60
50
40
30
20
10
0
10
100
1000
0.1
1
Frequency in MHz
10EJT
db 100
90
80
70
60
50
40
30
20
10
0
10
100
1000
0.1
1
Frequency in MHz
10
100
1000
Frequency in MHz
15EJT
db 100
90
80
70
60
50
40
30
20
10
0
0.1
1
20EJT
db 100
90
80
70
60
50
40
30
20
10
0
10
100
1000
0.1
1
Frequency in MHz
10
100
1000
Frequency in MHz
Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)
3
Power Inlet Filters & Power Entry Modules
Minimum Insertion Loss
Measured in closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)
Differential Mode / Symmetrical (Line to Line)
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.
165
For email, phone or live chat, please go to
te.com/help
corcom.com
Documents / Resources
![]() |
TE connectivity EJT1, EJT8 High Performance Power Inlet Filter [pdf] User Guide EJT1, EJT8, 20EJT1, 20EJT8, EJT1 EJT8 High Performance Power Inlet Filter, EJT1 EJT8, High Performance Power Inlet Filter, Performance Power Inlet Filter, Power Inlet Filter, Inlet Filter, Filter |