Specifications

  • Current Rating: 1, 3, 6, 10, 15, or 20A
  • Maximum Leakage Current:
    • @ 120 VAC 60 Hz:
      • 1-15A: 0.25 mA
      • 20A: 0.22 mA
    • @ 250 VAC 50 Hz:
      • 1-15A: 0.43 mA
      • 20A: 0.40 mA
  • Hipot Rating (One Minute): Line to Ground – 2250 VDC, Line to
    Line – 1450 VDC
  • Rated Voltage (Max): 250 VAC
  • Operating Frequency: 50/60 Hz
  • Operating Ambient Temperature Range: The maximum operating
    current (Io) is calculated as follows: Io = Ir (85-Ta)/45

Product Usage Instructions

Accessories

GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord

FA601: Insulating Shroud (fits 1-15A only)

Available Part Numbers

1EJT1, 3EJT1, 6EJT1, 10EJT1, 15EJT1, 20EJT1

1EJT8, 3EJT8, 6EJT8, 10EJT8, 15EJT8, 20EJT8

Electrical Schematics

LINE – Case Styles EJT1 – LOAD

Case Dimensions

Part No. A B C D E
EJT1 EJT8 20EJT1 20EJT8

Recommended Panel Cutouts

1 to 15A: A – 1.575″, B – 1.20″, R – .062″ Max., Dia. –
.820″

20A: A – 1.654″, B – 1.370″, R – .062″ Max., Dia. – .820″

FAQ

Q: What is the maximum rated voltage for the product?

A: The maximum rated voltage is 250 VAC.

Q: What is the operating ambient temperature range?

A: The operating ambient temperature range is calculated using
the formula Io = Ir (85-Ta)/45.

Q: Are there any accessories available for this product?

A: Yes, accessories like GA400 and FA601 are available for this
product.

“`

Corcom Product Guide High Performance Power Inlet Filter
EJT Series

Catalog: 1654001 Issue Date: 06.2011

UL Recognized CSA Certified VDE Approved*

EJT1

EJT8

Power Inlet Filters & Power Entry Modules

EJT Series
· Superior EMI filter with IEC 60320-1 inlet · Double three element differential mode circuit
attenuates noise up to 1GHz · Up to 15A with IEC 60320-1 C14 inlet · 20A rating with IEC 60320-1 C20 inlet · Spade terminals or wire leads
Ordering Information 6 EJT 1
Output Styles 1 ­ .250 [6.3] spade terminals 8 ­ Wire leads
EJT Series
Current Rating 1, 3, 6, 10, 15 or 20A

Specifications

Maximum leakage current each Line to Ground:

1-15A

20A

@ 120 VAC 60 Hz:

.25 mA

.22 mA

@250 VAC 50 Hz:

.43 mA

.40 mA

Hipot rating (one minute): Line to Ground: Line to Line:

2250 VDC 1450 VDC

Rated Voltage (max.):

250 VAC

Operating Frequency:

50/60 Hz

Rated Current:

1 to 20A*

Operating Ambient Temperature Range

(at rated current Ir):

-10°C to +40°C

In an ambient temperature (Ta) higher than +40°C

the maximum operating current (Io) is calculated as

follows: Io = Ir (85-Ta)/45

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord

3

Available Part Numbers
1EJT1 3EJT1 6EJT1 10EJT1 15EJT1 20EJT1

1EJT8 3EJT8 6EJT8 10EJT8 15EJT8 20EJT8

FA601: Insulating Shroud (fits 1-15A only)

.413 10.5

Dia.

.271 6.9

Dia.

*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC.
20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC.

.118 3.0
1.39 35.4

1.17 29.7

.767 19.5

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.

163
For email, phone or live chat, please go to
te.com/help
corcom.com

Downloaded from Arrow.com.

Corcom Product Guide

Catalog: 1654001 Issue Date: 06.2011

High Performance Power Inlet Filter (continued)

EJT Series

Electrical Schematics
LINE

Case Styles EJT1

LOAD
1 1

C
B D E

20EJT1

A

C
D E

EJT8

B
A

DE

Blue
Green/Yellow
B
Brown

A C

20EJT8
DE

Blue Green/Yellow
B
Brown

A

C

Case Dimensions

Part No.

A

B

EJT1 EJT8 20EJT1 20EJT8

C

D

E

Recommended Panel Cutouts

1 to 15A
1.575 40.00
1.20 30.48

20A
1.654 42.01 1.370 34.80

0.140 3.56

Dia.

.820 20.83

R

.062 1.57

Max.

0.138 3.51

Dia.

Front Mount Only Tolerance ±.005 [.13]

1.055 26.80

R

.062 1.57

Max.

164

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.

Downloaded from Arrow.com.

For email, phone or live chat, please go to te.com/help corcom.com

Corcom Product Guide

Catalog: 1654001 Issue Date: 06.2011

High Performance Power Inlet Filter (continued)

EJT Series

Performance Data

Typical Insertion Loss
Measured in closed 50 Ohm system

1EJT

3EJT

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

db 100

90

80

70

60

50

40

30

20

10

0

10

100

1000

0.1

1

Frequency in MHz

6EJT

db 100

90

80

70

60

50

40

30

20

10

0

10

100

1000

0.1

1

Frequency in MHz

10EJT

db 100

90

80

70

60

50

40

30

20

10

0

10

100

1000

0.1

1

Frequency in MHz

10

100

1000

Frequency in MHz

15EJT

db 100

90

80

70

60

50

40

30

20

10

0

0.1

1

20EJT

db 100

90

80

70

60

50

40

30

20

10

0

10

100

1000

0.1

1

Frequency in MHz

10

100

1000

Frequency in MHz

Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L)

3

Power Inlet Filters & Power Entry Modules

Minimum Insertion Loss
Measured in closed 50 Ohm system

Common Mode / Asymmetrical (Line to Ground)

Differential Mode / Symmetrical (Line to Line)

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change.
Downloaded from Arrow.com.

165
For email, phone or live chat, please go to
te.com/help
corcom.com

Documents / Resources

TE connectivity EJT1, EJT8 High Performance Power Inlet Filter [pdf] User Guide
EJT1, EJT8, 20EJT1, 20EJT8, EJT1 EJT8 High Performance Power Inlet Filter, EJT1 EJT8, High Performance Power Inlet Filter, Performance Power Inlet Filter, Power Inlet Filter, Inlet Filter, Filter

References

Leave a comment

Your email address will not be published. Required fields are marked *