TE Connectivity EJT Series High Performance Power Inlet Filter
Catalog: 1654001 | Issue Date: 06.2011
EJT Series
UL Recognized, CSA Certified, VDE Approved*
The EJT Series is a superior EMI filter with an IEC 60320-1 inlet. It features a double three-element differential mode circuit that attenuates noise up to 1GHz. Available in ratings up to 15A with IEC 60320-1 C14 inlet and 20A rating with IEC 60320-1 C20 inlet. Options include spade terminals or wire leads.
Specifications
Maximum leakage current each Line to Ground:
- 1-15A: 0.25 mA @ 120 VAC 60 Hz, 0.43 mA @ 250 VAC 50 Hz
- 20A: 0.22 mA @ 120 VAC 60 Hz, 0.40 mA @ 250 VAC 50 Hz
Hipot rating (one minute):
- Line to Ground: 2250 VDC
- Line to Line: 1450 VDC
Rated Voltage (max.): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 20A*
Operating Ambient Temperature Range (at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C, the maximum operating current (Io) is calculated as follows: Io = Ir √(85-Ta)/45
Ordering Information
EJT Series
Current Rating: 1, 3, 6, 10, 15 or 20A
Output Styles:
- 1 - 250 [6.3] spade terminals
- 8 - Wire leads
Available Part Numbers
1EJT1 | 1EJT8 |
3EJT1 | 3EJT8 |
6EJT1 | 6EJT8 |
10EJT1 | 10EJT8 |
15EJT1 | 15EJT8 |
20EJT1 | 20EJT8 |
*15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC. 20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC.
Accessories
- GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
- FA601: Insulating Shroud (fits 1-15A only)
Electrical Schematics
EJT Series
Case Styles:
EJT1
EJT8
20EJT1
20EJT8
Diagrams illustrating the electrical schematics and case styles for EJT1, EJT8, 20EJT1, and 20EJT8 models are provided, showing terminal configurations and mounting details.
Case Dimensions
Part No. | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] |
EJT1 | 2.74 [69.6] | 30.2 [767] | 0.875 [22.2] | 1.575 [40.0] | 1.98 [50.3] |
EJT8 | 2.74 [69.6] | 30.2 [767] | 0.875 [22.2] | 1.575 [40.0] | 1.98 [50.3] |
20EJT1 | 3.8 [96.5] | 30.2 [767] | 1.350 [34.3] | 1.654 [42.0] | 1.98 [50.3] |
20EJT8 | 3.8 [96.5] | 30.2 [767] | 1.350 [34.3] | 1.654 [42.0] | 1.98 [50.3] |
Recommended Panel Cutouts
Diagrams show recommended panel cutouts for 1 to 15A and 20A models, including dimensions in inches and millimeters.
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system. Graphs display insertion loss for Common Mode / Asymmetrical (L-G) and Differential Mode / Symmetrical (L-L) for 1EJT, 3EJT, 6EJT, 10EJT, 15EJT, and 20EJT models across various frequencies.
Minimum Insertion Loss
Measured in closed 50 Ohm system.
Common Mode / Asymmetrical (Line to Ground)
Current Rating | Frequency - MHz | |||||||
.15 | .5 | 1 | 5 | 10 | 30 | 100 | 1000 | |
1A | 27 | 33 | 40 | 59 | 65 | 65 | 61 | 14 |
3A | 22 | 30 | 34 | 57 | 63 | 69 | 61 | 10 |
6A | 13 | 21 | 27 | 51 | 60 | 65 | 59 | 14 |
10A | 7 | 14 | 21 | 43 | 52 | 61 | 61 | 14 |
15A | 4 | 10 | 15 | 38 | 48 | 63 | 63 | 14 |
20A | - | 8 | 15 | 42 | 50 | 60 | 58 | 14 |
Differential Mode / Symmetrical (Line to Line)
Current Rating | Frequency - MHz | |||||||
.15 | .5 | 1 | 5 | 10 | 30 | 100 | 1000 | |
1A | 10 | 20 | 23 | 43 | 52 | 65 | 45 | 14 |
3A | 10 | 20 | 24 | 41 | 51 | 59 | 52 | 17 |
6A | 10 | 21 | 24 | 37 | 48 | 65 | 55 | 20 |
10A | 10 | 21 | 25 | 28 | 44 | 63 | 53 | 18 |
15A | 10 | 20 | 26 | 25 | 36 | 56 | 45 | 23 |
20A | 9 | 20 | 26 | 40 | 35 | 48 | 50 | 10 |