MEAN WELL Mfululizo wa UHP-200A 200W Pato Moja na Utendaji wa PFC
Taarifa ya Bidhaa
Vipimo
Mfano | DC Voltage | Iliyokadiriwa Sasa | Masafa ya Sasa | Nguvu Iliyokadiriwa |
---|---|---|---|---|
UHP-200A-4.2 | 4.2V | 40A | 0~40A | 168W |
UHP-200A-4.5 | 4.5V | 40A | 0~40A | 180W |
UHP-200A-5 | 5V | 40A | 0~40A | 200W |
Pato:
- Udhibiti wa Mstari: N/A (Haijabainishwa kwenye mwongozo)
- Udhibiti wa mzigo: N/A (Haijabainishwa kwenye mwongozo)
- Wakati wa Kuweka: 2000ms kwa 230VAC, mzigo kamili
- Wakati wa Kupanda: 200ms kwa 230VAC, mzigo kamili
- Muda wa Kusimama (Aina.): 3000ms kwa 115VAC, mzigo wa 80%.
- Kazi ya DC Sawa: PSU huwasha wakati DC iko sawa; PSU huzima wakati DC inashindwa
Ingizo:
- VoltagAina: 90 ~ 264VAC
- Masafa ya Marudio: 47 ~ 63Hz
- Inrush ya Sasa (Aina.): 85A kwa 230VAC, kuanza kwa baridi
- Kipengele cha Nguvu (Aina.): 0.97 saa 115VAC, mzigo kamili; 0.95 kwa 230VAC, mzigo kamili
- Ufanisi (Aina.): 88%
- AC ya Sasa (Aina.): 2.4A katika 115VAC; 1.2A kwa 230VAC
- Uvujaji wa Sasa: N/A (Haijabainishwa kwenye mwongozo)
Maagizo ya Matumizi ya Bidhaa
Ufungaji
- Hakikisha kuwa usambazaji wa umeme umekatika kutoka kwa chanzo cha nishati.
- Unganisha vituo vya uingizaji wa umeme kwenye chanzo cha umeme cha AC kinachofaa kwa kutumia nyaya zinazotolewa.
- Unganisha vituo vya kutoa umeme kwenye kifaa chako kwa kutumia nyaya zinazofaa.
- Angalia miunganisho yote mara mbili ili kuhakikisha iko salama.
Uendeshaji
- Hakikisha kuwa usambazaji wa umeme umeunganishwa kwenye chanzo cha nishati.
- Washa usambazaji wa umeme kwa kutumia swichi ya umeme.
- Fuatilia chaguo la kukokotoa la DC OK ili kuhakikisha kuwa usambazaji wa nishati unafanya kazi ipasavyo.
- Rekebisha pato voltage ikiwa ni lazima kwa kutumia vidhibiti vilivyotolewa.
Matengenezo
Ili kuhakikisha maisha marefu na utendakazi bora zaidi wa usambazaji wa nishati, tafadhali fuata miongozo hii ya matengenezo:
- Kagua usambazaji wa umeme mara kwa mara kwa dalili zozote za uharibifu au uchakavu.
- Weka usambazaji wa umeme safi na usio na vumbi au uchafu.
- Epuka kufichua usambazaji wa umeme kwa halijoto kali au unyevunyevu.
- Usijaribu kufungua au kurekebisha usambazaji wa umeme mwenyewe. Wasiliana na fundi aliyehitimu kwa matengenezo au huduma yoyote.
Tahadhari za Usalama
Unapotumia usambazaji wa umeme, tafadhali zingatia tahadhari zifuatazo za usalama:
- Soma na uelewe maagizo yote yaliyotolewa kwenye mwongozo wa mtumiaji kabla ya kutumia usambazaji wa umeme.
- Hakikisha kuwa usambazaji wa umeme umeunganishwa kwenye mkondo uliowekwa msingi.
- Epuka kugusa vipengee vyovyote vya umeme vilivyo wazi wakati usambazaji wa umeme unafanya kazi.
- Usipakie usambazaji wa umeme kupita kiasi kwa kuunganisha vifaa vinavyozidi uwezo wake uliokadiriwa.
- Katika kesi ya tabia yoyote isiyo ya kawaida au utendakazi, ondoa usambazaji wa umeme mara moja kutoka kwa chanzo cha nguvu na uwasiliane na fundi aliyehitimu kwa usaidizi.
Maswali Yanayoulizwa Mara kwa Mara
- Swali: Juztage mbalimbali kwa ajili ya usambazaji wa nishati hii?
A: Juztage mbalimbali ya usambazaji wa nishati hii ni 90 ~ 264VAC. - Swali: Ni nguvu gani iliyokadiriwa kwa kila modeli?
J: Nguvu zilizokadiriwa kwa kila modeli ni kama ifuatavyo:- UHP-200A-4.2: 168W
- UHP-200A-4.5: 180W
- UHP-200A-5: 200W
- Swali: Ninawezaje kurekebisha ujazo wa patotage?
J: Unaweza kurekebisha sauti ya patotage kwa kutumia vidhibiti vilivyotolewa. Tafadhali rejelea mwongozo wa mtumiaji kwa maagizo maalum ya jinsi ya kurekebisha ujazotage.
Mwongozo wa Mtumiaji
Vipengele
- Ingizo la AC la Universal / Masafa kamili
- Kuhimili uingizaji wa 300VAC wa kuongezeka kwa sekunde 5
- Mtaalam wa chinifileurefu: 26 mm
- Kitendaji cha PFC kilichojumuishwa ndani
- Muundo usio na shabiki, upoezaji kwa kupitisha hewa bila malipo
- Kinga: Mzunguko mfupi / Upakiaji / Uzito wa ujazotage/Juu ya halijoto
- Uvujaji wa chini wa sasa <1.0mA
- Kiashiria cha LED cha kuwasha
- dhamana ya miaka 3
- Maombi
- Onyesho la alama za LED
- Ishara ya kusonga
- Barua ya kituo cha LED
- Ukuta wa TV ya LED
MSIMBO WA GTIN
Utafutaji wa MW: https://www.meanwell.com/serviceGTIN.aspx.
Maelezo
Mfululizo wa UHP-200A ni suluhu ya nguvu ya kuonyesha LED ya 200W. Pro wa chini kabisafile muundo huruhusu urefu na uzito wa moduli ya ishara kuwa ndogo. Inarahisisha sana mchakato wa utoaji na ufungaji. Uhasibu kwa ufanisi wa juu na kuokoa nishati, mfululizo huo unafanikisha kupunguza umeme. Inafaa kwa onyesho la alama za LED, ishara zinazosonga, barua ya chaneli ya LED kuta za TV za LED nk.
Usimbaji wa Mfano
MAALUM
MFANO | UHP-200A-4.2 | UHP-200A-4.5 | UHP-200A-5 | |
PATO |
DC VOLTAGE | 4.2V | 4.5V | 5V |
ILIYOPANGIWA SASA | 40A | 40A | 40A | |
MFUMO WA SASA | 0~40A | 0~40A | 0~40A | |
NGUVU ILIYOPIMA | 168W | 180W | 200W | |
RIPPLE & KELELE(max.) Kumbuka.2 | 200mVp-p | 200mVp-p | 200mVp-p | |
JUZUUTAGE ADJ. MBADALA | 4.0~4.4V | 4.3~4.7V | 4.7~5.3V | |
JUZUUTAGE UVUMILIVU Kumbuka.3 | ±4.0% | ±4.0% | ±4.0% | |
LINE USIMAMIZI | ±0.5% | ±0.5% | ±0.5% | |
KANUNI YA MZIGO | ±2.5% | ±2.5% | ±2.5% | |
KUWEKA, KUPANDA KWA WAKATI | 2000ms, 200ms/230VAC kwa mzigo kamili, 3000ms, 200ms/115VAC kwa mzigo wa 80%. | |||
SHIKA MUDA (Aina.) | 10ms/230VAC 10ms/115VAC | |||
DC OK KAZI | PSU Inawasha:DC sawa; PSU inazima: DC imeshindwa | |||
PEMBEJEO |
JUZUUTAGMBADALA Kumbuka.4 | 90 ~ 264VAC 127 ~ 370VDC | ||
MFUPIKO WA MAFUTA | 47 ~ 63Hz | |||
KIWANGO CHA SIMU (Aina.) | PF≥0.97/115VAC PF≥0.95/230VAC ikiwa imepakia kikamilifu | |||
UFANISI (Aina.) | 88% | 88% | 88.5% | |
AC SASA (Aina.) | 2.4A/115VAC 1.2A/230VAC | |||
INRUSH SASA (Aina.) | Kuanza kwa baridi 85A/230VAC | |||
KUVUJA KWA SASA | <1.0mA / 240VAC | |||
ULINZI |
PAKIA | Nguvu ya pato iliyokadiriwa 110-140%. | ||
Aina ya ulinzi : Hali ya Hiccup, hupona kiotomatiki baada ya hali ya hitilafu kuondolewa | ||||
MZUNGUKO MFUPI | Aina ya ulinzi : Hali ya Hiccup, hupona kiotomatiki baada ya hali ya hitilafu kuondolewa | |||
JUU YA VOLTAGE | 4.6 ~ 6V | 5 ~ 6.4V | 5.6 ~ 7.1V | |
Aina ya ulinzi : Hali ya Hiccup, hupona kiotomatiki baada ya hali ya hitilafu kuondolewa | ||||
JUU YA JOTO | Aina ya ulinzi : Zima sauti ya O/Ptage, hupona kiatomati baada ya hali ya kosa kuondolewa | |||
MAZINGIRA |
TEMP YA KAZI. | -30 ~ +70℃(Rejelea “OUTPUT LOAD vs TEMPERATURE”) | ||
UNYEVU WA KAZI | 20 ~ 95% RH mashirika yasiyo ya kondensorpannor | |||
HIFADHI TEMP., UNYEVU | -40 ~ + 85 ℃, 10 ~ 95% RH | |||
Temp. Mgawo | ± 0.03% / ℃ (0 ~ 50 ℃) | |||
Mtetemo | 10 ~ 500Hz, 5G 10min./1mzunguko, 60min. kila moja pamoja na shoka X, Y, Z | |||
USALAMA & EMC (Kumbuka.5) |
VIWANGO VYA USALAMA | UL 62368-1,TUV BS EN/EN62368-1,CCC GB4943, EAC TP TC 004 imeidhinishwa | ||
ZUIA VOLTAGE | I/PO/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
UKINGA WA KUTENGWA | I/PO/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25℃/ 70%RH | |||
Ujumbe wa UTOAJI WA EMC.8 | Kuzingatia BS EN/EN55032 (CISPR32),GB9254,Hatari A, BS EN/EN61000-3-2,-3,GB17625.1,EAC TP TC 020 | |||
KIWANJO CHA EMC | Kuzingatia BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN55035, kiwango cha sekta nyepesi (surge 4KV),EAC TP TC 020 | |||
MENGINEYO |
MTBF | 1949.0 Saa za K. Telcordia SR-332 (Bellcore); Dakika ya saa 211.7K. MIL-HDBK-217F (25℃) | ||
DIMENSION | 167*55*26mm (L*W*H) | |||
KUFUNGA | 0.42kg; 20pcs/ 11.4kg/0.76CUFT | |||
KUMBUKA |
Kanusho la Dhima ya Bidhaa: Kwa habari zaidi, tafadhali rejelea https://www.meanwell.com/serviceDisclaimer.aspx. |
Mchoro wa Zuia
- Msingi wa PFC: 65KHz
- PWM fosc: 75 ~ 200KHz
MZIGO WA PATO dhidi ya JOTO
TABIA ZA TABIA
Uainishaji wa Mitambo
- KESI NO.: 249A
- Kitengo: mm
AC Input Terminal(TB1) pin NO. Mgawo
Pina Hapana. | Mgawo | Kituo | Kiwango cha juu cha kuweka torque | ||
1 | AC / L | (DECA) | 13Kgf-cm | ||
2 | AC / N. | ||||
3 | ![]() |
||||
Kiunganishi cha DC OK(CN1):JST B2B-PH-KS au sawa
Pina Hapana. | Mgawo | Makazi ya Kuoana | Kituo |
1 | DC Sawa +V | JST PHR-2
au sawa |
JST SPH-002T-P0.5S
au sawa |
2 | DC COM |
DC Output Terminal(TB2,TB3) pin NO. Mgawo
Pina Hapana. | Mgawo | Kituo | Kiwango cha juu cha kuweka torque |
1,2 | -V | (MW)
TB-HTP-200-40A |
8Kgf-cm |
3,4 | +V |
Mwongozo wa Kazi
Mzunguko wa ndani wa DC sawa
Wasiliana Karibu | PSU huwasha | DC sawa |
Wasiliana na Fungua | PSU huzima | DC kushindwa |
Ukadiriaji wa Anwani(max.) | 10Vdc/1mA |
Ufungaji
- Fanya kazi na sahani ya ziada ya alumini
Ili kukidhi "Derating Curve" na "Tabia Tuli", mfululizo wa UHP-200A lazima usakinishwe kwenye sahani ya alumini (au kabati la ukubwa sawa) chini. Ukubwa wa sahani ya alumini iliyopendekezwa imeonyeshwa hapa chini. Ili kuboresha utendaji wa mafuta, sahani ya alumini lazima iwe na uso sawa na laini (au ipakwe kwa grisi ya mafuta), na safu za UHP-200A lazima zimefungwa vizuri katikati ya sahani ya alumini. - Kwa utaftaji wa joto, angalau umbali wa ufungaji wa 5cm kuzunguka PSU inapaswa kuwekwa, iliyoonyeshwa hapa chini: