Sunco CL_RD_DD-BK-2760K Outdoor Ceiling Light With Motion Sensor
What’s in the Box?
Ceiling Light
Get Your Gear
Before You Start
Safety Information
To reduce the risk of fire, electric shock, or physical injury:
- Turn off circuit breaker before installing this fixture.
- This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
- Abide by related regional and local laws or regulations.
- Proper grounding is required to ensure safety.
- Do not alter, relocate, or remove wiring during installation.
- Do not make or alter any open holes in wiring enclosure or electrical components during installation.
- Check for shipping damage before installing. If the product is damaged, do not use it.
- Keep fixture away from corrosive substances.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference.
- Suitable for damp locations at temperature ranging from – 4°F to 104°F. Not for use where directly exposed to water.
- Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
- Use safety precautions and abide by regional and local laws or regulations.
- This product is not compatible with 3rd party sensors.
- This product is not compatible with photo controls.
- This product is not compatible with occupancy sensors.
- This product is not compatible with timing devices.
WARNING:
Cancer & Reproductive Harm- www.P65Warnings.ca.gov
- This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.
Quickstart Guide
- Remove lens from luminaire base.
- Install mounting screws to j-box.
- Connect supply wires with luminaire wires.
- Install lens by twisting fixture to lock luminaire.
Installation Guide
- STEP 1
Turn off circuit breaker that provides power to the light. - STEP 2
Twist the sides of the white luminaire base counter clockwise to remove lens. - STEP 3
- For junction box installation, the slot distance should be approximately 2.63 – 3.41”.
- Install mounting screws (B) to junction box.
STEP 4
- Feed luminaire wires through junction box.
- Connect supply wires to luminaire wires with included wire nuts (A):
- Black to Black (Live)
- White to White (Neutral)
- Bare Copper to Bare Copper (Ground)
- Tuck all wires into junction box.
- STEP 5
- Align keyhole slots of luminaire base to the mounting screws (B) on the junction box.
- Twist luminaire into place, then tighten mounting screws (B) to hang luminaire to ceiling.
- STEP 6
- Use the CCT switch on the luminaire base to select desired CCT.
- STEP 7
- Install lens back to luminaire, then twist lens clockwise until it locks into place.
- For the motion sensor, the luminaire will turn on when motion is detected and daylight is not detected.
- STEP 7
- Turn on circuit breaker to test light.
Test Mode - To test for motion detection, toggle the light into factory test mode. Turn the luminaire off/on five times.
- The luminaire will flash three times when set to TEST mode.
- If motion is detected, the light will turn on, then turn off.
Note: To exit TEST mode, simply turn the light off and on again.
- Turn on circuit breaker to test light.
Product Details
Product Size
Specifications
Common Troubleshooting
Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy-to-follow solutions for any problem.
If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.
Installation
- Light isn’t turning on. Double check if fixture is properly connected and circuit breaker hasn’t been tripped.
- Light unexpectedly fails. For further assistance, reach out to customer support.
Flickering
Buzzing
- Fixture buzzing with power outages. Verify light is connected to surge protector securely.
- Fixture buzzing with appliances or electronic devices. Look for nearby interferences that can cause buzzing. Such as televisions, radios, computers, etc.
- Fixture buzzing when dimmed. Fixture is not dimmable.
Light Distribution Angle
Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:
A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.- An asymmetric lighting distribution angle, also known as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums,
and much more. - It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.
Lighting made better.
support@sunco.com 844-334-9938
Documents / Resources
![]() |
Sunco CL_RD_DD-BK-2760K Outdoor Ceiling Light With Motion Sensor [pdf] User Manual CL_RD_DD-BK-2760K, CL_RD_DD-BK-2760K Outdoor Ceiling Light With Motion Sensor, CL_RD_DD-BK-2760K, Outdoor Ceiling Light With Motion Sensor, Ceiling Light With Motion Sensor, Motion Sensor, Sensor |