1. Bubuka

This manual provides detailed instructions for the Waveshare Industrial Modbus RTU 4-Channel Relay Module. This module is designed for industrial control applications, offering robust RS485 communication, high current switching capabilities, and comprehensive protection features. It is suitable for various scenarios requiring intelligent and automated control.

Waveshare Industrial Modbus RTU 4-Channel Relay Module

Gambar 1.1: Leuwihview of the Waveshare Industrial Modbus RTU 4-Channel Relay Module.

2. Fitur konci

3. Eusi Paket

pakét ngawengku item handap:

Note: The power supply for this product is not included. A 12V power supply is recommended. A USB to RS232/485/TTL or USB to RS485 converter may be useful for testing and communication setup.

Package contents of Waveshare Modbus RTU Relay 4CH

Image 3.1: Contents of the product package, showing the Modbus RTU Relay 4CH module.

4. Spésifikasi

ParameterNilai
Sasayogian tanaga7-36V
Antarbeungeut KomunikasiRS485
Baudrat4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Format Komunikasi Standar9600, N, 8, 1
Saluran Relay4
Formulir Kontak1NO 1NC (Normally Open, Normally Closed)
Kontak Rating≤30A 250V AC or ≤30A 28V DC
Protokol KomunikasiProtokol Modbus RTU standar
Alamat RS4851-255 (Configurable)
Indikator LEDSTA: MCU indicator (keeps flashing when MCU is working normally)
TXD: TX indicator (lights up when sending data)
RXD: RX indicator (lights up when receiving data)
Tipe PamasanganDIN Rail Gunung
Bahan Kontakpérak
Tipe PanyambungTerminal screw
Detailed features and specifications of the Waveshare Modbus RTU Relay Module

Image 4.1: Visual representation of the module's features and technical specifications.

5. Setup jeung Instalasi

5.1 Sambungan Power Supply

Connect a 7V to 36V DC power supply to the designated power input terminals on the module. Ensure correct polarity (+ and -). The module features an onboard voltage regulator and power supply isolation for stable operation.

5.2 RS485 Interface Connection

Connect the RS485 A+ and B- terminals of the module to your RS485 master device (e.g., a computer via a USB to RS485 converter). For multi-device setups, ensure proper cascading and consider using RS485 repeaters for long communication distances.

RS485 communication wiring diagram and relay connection examples

Image 5.1: Diagram illustrating RS485 communication setup with multiple modules and examples of AC and DC relay connections.

5.3 Relay Kaluaran Connection

Each of the 4 relay channels provides Normally Open (NO) and Normally Closed (NC) contacts, along with a Common (COM) terminal. Connect your target device (e.g., light, motor, valve) to the appropriate relay contacts based on your control requirements. The high current screw terminals are designed for secure wiring of devices up to 30A.

Close-up of high current screw terminals and internal hardware components

Gambar 5.2: Detil view of the high current screw terminals and a hardware analysis showing internal components like optocoupler isolation and TVS protection.

5.4 Rail-Mount Installation

The module is housed in a rail-mounted ABS plastic enclosure, facilitating easy installation and removal on standard DIN rails in industrial control cabinets.

Diagram showing LED indicators and enclosure design for DIN rail mounting

Image 5.3: Illustration of the module's interfaces, LED indicators, and its rail-mount enclosure design.

6. Parentah Operasi

6.1 Modbus RTU Communication

The module communicates using the standard Modbus RTU protocol over the RS485 interface. You can send Modbus commands from a master device to control the relays and read their status. The device address is configurable from 1 to 255.

For detailed Modbus command structures and register maps, refer to the official Waveshare Wiki resources.

6.2 Relay Control

Relays can be controlled individually or in groups using Modbus commands. The module supports standard ON/OFF commands. Additionally, a flash-on/flash-off function allows a relay to be activated for a specified duration before automatically deactivating.

6.3 Indikator LED

These indicators provide visual feedback on the module's operational status and communication activity.

6.4 Kelample of Modbus Control

The following video demonstrates the Modbus RTU Relay series, including connection and basic operation using Modbus commands. This can serve as a practical guide for controlling the module.

Video 6.1: Hiji leuwihview of the Waveshare Modbus RTU Relay series, demonstrating various models and their operational principles. This video highlights the features and application scenarios of the relay modules.

7. Aplikasi

The Waveshare Modbus RTU Relay Module is versatile and can be applied in various fields:

Various application scenarios including industrial control, smart home, smart agriculture, and breeding & farming

Gambar 7.1: Examples of diverse applications for the Modbus RTU Relay Module.

8. Pangropéa

The Waveshare Modbus RTU Relay Module is designed for reliable operation with minimal maintenance. To ensure longevity and optimal performance:

9. Cara ngungkulan

If you encounter issues with your Modbus RTU Relay Module, consider the following troubleshooting steps:

For further assistance, consult the Waveshare Wiki or contact technical support.

10. Garansi jeung Rojongan

For detailed warranty information, please refer to the official Waveshare website or the documentation provided with your purchase. Waveshare provides comprehensive resources and support for its products.

Dokumén Patali - Modbus RTU 4-Channel Relay Module

Praview Module d'Entrée Analogique Modbus RTU 8 Canaux par Waveshare
Téhnik dokumén présente le modul d'entrée analogique 8 canaux Modbus RTU de Waveshare, conçu pour l'acquisition de données de tension et de courant jeung les systèmes d'automatisation industrielle. Téhnik spécifications détailles, les méthodes de connexion, les test logiciels and le protocole de communication Modbus.
Praview Modbus RTU Relay: Manual pamaké sarta Guide Téknis
Pituduh komprehensif pikeun Modbus RTU Relay, ngawengku parentah kaamanan, sambungan hardware, setup software kalawan SSCOM na Modbus Poll, sarta protokol paréntah lengkep pikeun sagala rupa operasi. Ngawengku examppikeun integrasi Raspberry Pi, STM32, Arduino, sareng PLC.
Praview Modbus RTU Relay 32CH Pamaké Manual jeung Téknis Guide
Buku petunjuk lengkep sareng pituduh téknis pikeun Modbus RTU Relay 32CH. Nyertakeun kaamanan, hardware, integrasi software (Raspberry Pi, STM32, Arduino, PLC), sarta protokol paréntah Modbus RTU pikeun automation industri.
Praview Waveshare Modbus POE ETH Relay 30CH: User Manual and Configuration Guide
This document provides a comprehensive guide to the Waveshare Modbus POE ETH Relay 30CH. It covers product overview, hardware connection, electrical safety precautions, detailed specifications, indicator descriptions, configuration methods using VirCom software and web interface, protocol settings (Modbus RTU/TCP), virtual serial port setup, software demonstrations with SSCOM and Modbus Poll, Raspberry Pi integration, and Modbus development protocols. Learn how to control and monitor industrial automation devices.