Reznor UDXC-45

Buku Panduan Pemanas Unit Gas Alam Reznor UDXC-45

Model: UDXC-45

1. Bubuka

The Reznor UDXC-45 is a 45,000 BTU natural gas unit heater designed for indoor use in various spaces, including commercial, industrial, and residential garages, workshops, and warehouses. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your heater. Please read all instructions thoroughly before proceeding with installation or operation.

2. Émbaran Kasalametan

PERHATOSAN: Pamasangan, panyesuaian, parobahan, palayanan, atanapi pangropéa anu teu leres tiasa nyababkeun karusakan harta, tatu, atanapi maot. Baca paréntah pamasangan, operasi, sareng pangropéa sacara saksama sateuacan masang atanapi ngalayanan alat ieu.

  • Pasokan Gas: Ensure the gas supply is turned off before any installation or maintenance. All gas connections must be leak-tested.
  • Ventilasi: Proper venting is critical to prevent carbon monoxide poisoning. Ensure the vertical Category 1 B-vent kit is installed correctly and maintained.
  • Sambungan listrik: All electrical wiring must comply with local codes and be performed by a qualified electrician. Disconnect power before servicing.
  • Clearances: Maintain adequate clearances from combustible materials as specified in the installation instructions.
  • Pamasangan profésional: Installation and service should be performed by a qualified installer, service agency, or gas supplier.

3. Produk Langkungview

The Reznor UDXC-45 unit heater is engineered for durability and efficient heating. It features a robust design suitable for demanding environments.

Reznor UDXC-45 Unit Heater with key features listed

Gambar: Hareupeun view of the Reznor UDXC-45 unit heater highlighting standard features such as 83% AFUE efficiency and TCORE2 heat exchanger.

Fitur konci:

  • Kinerja luhur: Rated for 45,000 BTU with an 83% thermal efficiency rating.
  • Konstruksi awét: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger.
  • Ignition canggih: Patented single-burner combustion with multi-try direct spark ignition and time lockout.
  • Panganteur pamaké: Integrated circuit board with a 7-segment display for troubleshooting and status-indicating LED.
  • Operasi sepi: Low noise operation with vibration-isolated fan and venter motors.
  • Fleksibilitas instalasi: Threaded-nut retainers at four suspension points for ceiling or wall mounting (mounting hardware sold separately).
  • Aksés pangropéa: Hinged access door panel with a quarter-turn latch and external gas connection for ease of maintenance.
Icons representing scratch resistance, durable build, modern design, and quiet operation

Image: Visual representation of the heater's attributes including scratch resistance, durable build, modern design, and quiet operation.

4. Spésifikasi

Detailed technical specifications for the Reznor UDXC-45 unit heater.

Diagram showing dimensions of the 45,000 BTU Reznor heater

Image: Diagram illustrating the physical dimensions of the 45,000 BTU Reznor UDXC-45 heater.

SpésifikasiNilai
Nomer modélUDXC-45
Kaluaran Panas45,000 British Thermal Units (BTU)
Éféktivitas termal83%
Tipe SuluhGas alam
Métode pemanasanHawa Kapaksa
Pamakéan jero rohangan / outdoorjero rohangan
Faktor BentukSiling-Dipasang
Ukuran produk (D x W x H)29.75" x 27" x 13.75"
Jumlah Speeds2

5. Pamasangan

The Reznor UDXC-45 is designed for ceiling or wall mounting. A vertical Category 1 double wall B-vent kit is included for roof venting. Consult a qualified professional for installation to ensure compliance with all local codes and safety standards.

Pamasangan:

  • The unit features threaded-nut retainers at four suspension points for secure mounting.
  • Mounting hardware is sold separately and should be selected based on the specific installation environment and structural requirements.
  • Ensure the mounting location can support the weight of the unit and provides adequate clearance from combustible surfaces.
Reznor UDXC-45 heater installed on a ceiling in a garage

Image: A Reznor UDXC-45 heater mounted on a ceiling, demonstrating a typical installation in a garage or workshop setting.

Venting:

The included vertical Category 1 double wall B-vent kit is essential for safely expelling combustion byproducts. Follow the kit's instructions and local codes for proper installation.

  • The kit typically includes components such as a Reznor CCI Vent Cap, Draft Hood Connector, Straight Pipes (12" and 24" lengths), Adjustable Elbows (60° and 90°), Roof Flashing, and a Storm Collar.
  • Ensure all vent connections are sealed properly to prevent leaks.
Components of a 4-inch diameter double wall B-vent kit

Image: Various components of a 4-inch diameter double wall B-vent kit, used for vertical venting applications.

6. Operasi

Once properly installed and connected to the natural gas and electrical supplies, the Reznor UDXC-45 heater is ready for operation. This unit utilizes forced air for efficient heat distribution.

Ngamimitian Pemanas:

  1. Ensure the gas supply valve to the heater is open.
  2. Hurungkeun kakuatan listrik ka unit.
  3. Set the thermostat to the desired temperature. The heater will initiate its ignition sequence.
  4. Observe the status-indicating LED and 7-segment display for operational status.

Sirkulasi hawa:

The low static pressure axial fan and power venting system are designed to reduce heat loss and ensure effective air circulation throughout the heated space.

Diagram illustrating air circulation patterns from a unit heater

Image: A diagram showing the air circulation patterns generated by a unit heater, indicating effective heat distribution.

7. Pangropéa

Regular maintenance ensures the longevity and efficient operation of your Reznor UDXC-45 heater. Always disconnect electrical power and turn off the gas supply before performing any maintenance.

  • Inspeksi taunan: Have a qualified service technician inspect the heater annually, including the heat exchanger, burner, ignition system, and venting.
  • beberesih: Keep the area around the heater clean and free of obstructions. Periodically clean the fan blades and motor to prevent dust buildup.
  • Pamariksaan Sistem Ventilasi: Inspect the vent system for any signs of corrosion, blockages, or leaks. Ensure the vent cap is clear.
  • Panas Exchanger: The TCORE2 titanium-stabilized aluminized steel heat exchanger is designed for durability, but should be inspected for any signs of damage or wear during annual service.

8. Cara ngungkulan

The Reznor UDXC-45 is equipped with an integrated circuit board and a 7-segment display for diagnostics, along with a status-indicating LED to assist in troubleshooting. Refer to the specific error codes displayed on the 7-segment display for detailed guidance.

Masalah umum:

  • Henteu Panas: Check if the thermostat is set correctly, the gas supply is open, and the electrical power is on. Look for error codes on the display.
  • Pilot Light/Ignition Failure: The multi-try direct spark ignition system will attempt to light the burner multiple times. If it fails, an error code will be displayed. This may indicate a gas supply issue or a problem with the ignition components.
  • Sora anu teu biasa: While designed for quiet operation, any new or unusual noises should be investigated. This could indicate a fan issue or other mechanical problem.
  • Heater Cycles On/Off Frequently: This could be due to an improperly sized unit, thermostat placement, or airflow restrictions.

Pikeun masalah anu terus-terusan atanapi masalah anu rumit, hubungi teknisi servis anu mumpuni.

9. Garansi jeung Rojongan

For warranty information, please refer to the documentation provided with your Reznor UDXC-45 unit heater or contact the manufacturer directly. Support for this product may also be available through the seller, 1HVAC. Keep your purchase receipt and model number (UDXC-45) handy when contacting support.

Dokumén Patali - UDXC-45

Praview Reznor siling gantung Kit Instalasi Guide pikeun Electric jeung Gas-dipecat Unit pamanas
parentah instalasi tur rinci komponén pikeun Reznor CK22 siling gantung Kit, cocog sareng EHU listrik sarta UDXC, UDX, UDZ gas-dipecat Unit pamanas. Diajar kumaha carana masang manaskeun Reznor anjeun aman.
Praview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Praview Pamasangan Kit Gantung Ceiling Reznor pikeun Pemanas Unit Listrik sareng Gas (Pilihan CK22)
Pituduh pamasangan pikeun Reznor CK22 Ceiling Suspension Kit, dirancang pikeun EHU, UDX, UDXC, sareng UDZ listrik sareng pamanas unit gas. Ngawengku komponén kit sareng léngkah pamasangan.
Praview Reznor Unit Heater Venting Instructions for UBX and UDX Models
Comprehensive venting instructions for Reznor UBX (Standard Power Vent Blower Type) and UDX (Standard Power Vent Fan Type) unit heaters. Covers general information, safety precautions, venting requirements, condensation mitigation, vent terminal specifications, and installation procedures for both commercial/industrial and residential applications.
Praview Pituduh Instalasi Kit Reznor Vertical Louver pikeun Pemanas Unit Dipecat Gas (OPT-CD1)
Parentah instalasi pikeun Reznor OPT-CD1 nangtung Louver Kit, dirancang pikeun pamanas Unit gas-dipecat (model UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Ngawengku daptar komponén sareng pituduh rakitan léngkah-léngkah.
Praview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)