ACiQ ACiQ-18-AC

ACiQ Brand Logo Banner

ACiQ 1.5 Ton 16 SEER2 Central Air Conditioner System

model: ACiQ-18-AC

1. Bubuka

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your ACiQ 1.5 Ton 16 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before attempting any procedures. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

ACiQ 1.5 Ton Central Air Conditioner System with Installation Kit

Gambar 1.1: Leuwihview of the ACiQ 1.5 Ton Central Air Conditioner System and included installation kit.

2. Émbaran Kasalametan

WARNING: Installation and servicing of this equipment can be hazardous due to system pressure, electrical components, and sharp edges. Only qualified, trained, and licensed HVAC technicians should install, repair, or service this equipment. Failure to follow this warning could result in property damage, personal injury, or death.

  • Salawasna pegatkeun sambungan kakuatan ka unit saméméh ngalakukeun sagala pangropéa atawa jasa.
  • Anggo alat pelindung diri (APD) anu merenah, kalebet sarung tangan sareng pelindung panon.
  • Pastikeun grounding ditangtoskeun sadaya komponén listrik.
  • Do not operate the unit with damaged electrical cords or components.
  • Jauhkeun barudak sareng piaraan tina unit salami operasi sareng perawatan.

3. Eusi Paket

Pastikeun yén sadaya komponén anu didaptarkeun di handap aya dina pakét anjeun:

  • Unit Condenser outdoor
  • Indoor Evaporator Cased Coil (Multi-Positional)
  • Smart WiFi Thermostat
  • Set Tali Insulated 30' (3/8" LL x 3/4" SL x 3/8")
  • Pecut Listrik Ukuran 1/2" x 6' 10
  • Saklar Pemutus Sambungan 60A Anu Henteu Ngahiji
  • Kontrol Pelindung Lonjakan
  • Adaptor Ngecas CPS
  • Tembok leungeun baju
  • Tembok Gunung Bracket
  • Manual pangguna (dokumén ieu)
Complete ACiQ Split System Installation Kit Components

Image 3.1: Components included in the ACiQ Split System Installation Kit.

4. Produk Langkungview jeung Fitur

4.1. Inverter AC Technology

The ACiQ system utilizes inverter technology, which allows the compressor to adjust its speed continuously. This precise control maintains a consistent indoor temperature, reduces energy consumption, and results in quieter operation compared to traditional single-stagsistem e.

4.2. Multi-Positional Evaporator Cased Coil

The included cased coil is designed for multi-positional installation, offering flexibility for various HVAC system configurations. It features a factory-integrated TXV (Thermostatic Expansion Valve) for optimized refrigerant flow and enhanced system efficiency.

4.3. Smart Thermostat

The system comes with a Smart WiFi Thermostat, enabling remote control and advanced scheduling features. It integrates with popular smart home platforms for convenient management of your home's climate.

ACiQ Air Conditioner Features Overview

Image 4.1: Key features of the ACiQ Air Conditioner, including inverter technology, gold fin coil, and quiet operation.

Smart Thermostat Features and Interface

Image 4.2: Detailed features and interface of the included Smart Thermostat.

5. Spésifikasi

SpésifikasiNilai
Ngaran BrandACiQ
Info modélACiQ-18-AC / ACIQ-24-ACL / IKIC31
Kapasitas1.5 Ton (18000 BTU/h)
Peunteun SEER2Nepi ka 16.8
Voltage230 volt
Wattage1538 watt
Tipe PamasanganSistem Pamisah
Faktor BentukSistem Pamisah Pusat
Fitur hususUnit Inverter, Sensor Pinter, Kumparan Sirip Emas, Ultra-Sepi, Performa Sadaya Iklim
Panutup Wewengkon LantaiNepi ka 900 suku pasagi
Outdoor Condenser Dimensions (D x W x H)13.46 x 35.04 x 26.5 inci
Evaporator Coil Dimensions (W x D x H)17.52 x 20.98 x 17.99 inci
Evaporator Coil Air Flow720.04 CFM
Evaporator Coil Dehumidification3.02
ACiQ Outdoor Condenser and Evaporator Coil Dimensions

Image 5.1: Dimensional measurements for the ACiQ outdoor condenser and evaporator coil.

ACiQ Evaporator Coil Specifications

Image 5.2: Detailed specifications for the ACiQ evaporator coil.

6. Setup jeung Instalasi

IMPORTANT: This ACiQ Central Air Conditioner System requires professional installation by a qualified and licensed HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, voided warranty, and improper operation.

6.1. Cék Pra-Pamasangan

  1. Ensure the installation site meets local building codes and regulations.
  2. Verify that the electrical supply matches the unit's requirements (230 Volts).
  3. Confirm adequate space for both the outdoor condenser and indoor evaporator coil, allowing for proper airflow and service access.

6.2. Léngkah-léngkah Instalasi (Leuwihview pikeun Teknisi)

  1. Mounting the Outdoor Condenser: Securely mount the outdoor unit using the provided wall mount bracket or a suitable ground-level pad, ensuring proper drainage and vibration isolation.
  2. Installing the Indoor Evaporator Coil: Integrate the multi-positional cased coil with your existing furnace or air handler, ensuring proper sealing and airflow.
  3. Nyambungkeun Jalur Refrigerant: Connect the insulated line set between the outdoor and indoor units. This involves brazing and vacuuming the lines to remove moisture and non-condensable gases, followed by charging with R410A refrigerant.
  4. Kawat listrik: Connect the electrical whip, disconnect switch, and controls surge protector according to wiring diagrams provided with the unit and local electrical codes. Connect the smart thermostat.
  5. System Start-up and Testing: Perform a leak check, verify proper refrigerant charge, test all operational modes, and calibrate the thermostat.

7. Parentah Operasi

Once professionally installed, your ACiQ system is designed for user-friendly operation primarily through the Smart WiFi Thermostat.

7.1. Smart Thermostat Operation

Refer to the separate Smart WiFi Thermostat manual for detailed instructions on its features, including:

  • Setting desired temperature (cooling/heating set points).
  • Selecting operating modes (Cool, Heat, Auto, Fan Only).
  • Programming schedules and presets.
  • Connecting to your home's WiFi network for remote access via a mobile application.
  • Integration with voice assistants (e.g., Alexa, Google Assistant) and smart home platforms (e.g., SmartThings, IFTTT).

7.2. Inverter Technology Benefits

The inverter system automatically adjusts its output to match the cooling demand, providing consistent comfort and energy savings. You may notice the compressor running at varying speeds, which is normal operation for an inverter unit.

8. Pangropéa

Regular maintenance ensures the efficiency and longevity of your ACiQ system. Some tasks can be performed by the homeowner, while others require a professional technician.

8.1. Pangropéa pamaké

  • Bersihkeun atanapi Ganti Saringan Udara: Check your furnace/air handler's air filter monthly and clean or replace it as needed. A dirty filter restricts airflow and reduces efficiency. The system uses a washable, reusable mesh filter.
  • Unit Luar Ruangan Anu Jelas: Keep the area around the outdoor condenser unit free from debris, leaves, and vegetation to ensure proper airflow.
  • Clean Evaporator Coil Drain Pan: Periodically check and clean the condensate drain pan to prevent clogs and water overflow.

8.2. Professional Maintenance

Schedule annual maintenance with a qualified HVAC technician. This typically includes:

  • Mariksa tingkat sareng tekanan refrigeran.
  • Cleaning condenser and evaporator coils.
  • Mariksa sambungan listrik sareng komponénna.
  • Ngalumaskeun bagian anu obah (upami aya).
  • Mariksa kalibrasi termostat.
  • Mariksa saluran pipa pikeun ayana bocor.

9. Cara ngungkulan

Sateuacan nelepon pikeun layanan, ulangview masalah umum sareng solusi ieu:

MasalahMungkin Cukang lantarananaSolusi
System not cooling/heatingThermostat setting incorrect, dirty air filter, power supply issue, tripped breaker.Check thermostat settings, replace/clean filter, check circuit breaker, ensure power is on.
Aliran hawa goréngDirty air filter, blocked vents, obstructed outdoor unit.Clean/replace filter, ensure vents are open, clear debris from outdoor unit.
Sora anu teu biasaLoose parts, debris in fan, refrigerant issues.Inspect for loose panels or debris. If persistent, contact a technician.
Leak caiSaluran pembuangan kondensat mampet, koil evaporator beku.Clear drain line. If coil is frozen, turn off unit and contact a technician.

If these steps do not resolve the issue, contact a qualified HVAC technician for further diagnosis and repair.

10. Garansi jeung Rojongan

10.1. Sarat jaminan

Your ACiQ Central Air Conditioner System comes with a warranty of 7 taun dina bagian jeung 12 taun nganggo kompresor. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please retain your proof of purchase and installation records.

10.2. Rojongan Palanggan

For technical assistance, warranty claims, or to locate a certified service provider, please visit the official ACiQ website or contact their customer support line. (Specific contact details are typically provided on the manufacturer's website or warranty card.)

11. AHRI Rating Conditions

AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification is essential for HVAC units as it assures performance, energy efficiency, quality, regulatory compliance, and provides benefits like market differentiation, financial incentives, and consumer protection.

AHRI Certified Rating and EnergyGuide Label for ACiQ System

Image 11.1: AHRI Certification and EnergyGuide label details for the ACiQ system, showing SEER2 rating and cooling capacity.

The manufacturer of this ACiQ product is responsible for the rating of this system combination. The unit is rated as follows in accordance with the latest edition of AHRI 210/240-2024, Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment:

  • AHRI Certified Number: 214731227
  • Tanggal: 08-26-2024
  • Model Status: Aktif
  • AHRI Type: RCU-A-C (Split System: Air-Cooled Condensing Unit, Coil Alone)
  • Ngaran Brand: ACiQ
  • Unit outdoor: ACiQ-18-AC
  • Unit Indoor: ACiQ-24-ACL
  • Cooling Capacity BTU/h: 18000
  • SEER2: 16.00
  • EER2 Single or High Stage: 11.70

Dokumén Patali - ACiQ-18-AC

Praview Manual Pamasangan Unit Luar Ruangan Sistem Inverter Sentral ACiQ
Manual pamasangan lengkep pikeun unit luar ruangan ACiQ Central Inverter Systems, anu ngawengku tindakan pencegahan kaamanan, pipa refrigeran, pamasangan unit luar ruangan, kabel, spésifikasi daya, evakuasi hawa, sareng prosedur uji coba. Ngawengku rinci modél sareng catetan penting pikeun setelan anu leres.
Praview Manual Pamasangan Sistem Inverter Sentral ACiQ
Manual pamasangan lengkep pikeun Sistem AC sareng Pompa Panas Inverter Sentral ACiQ, anu ngajelaskeun sacara rinci tindakan pencegahan kaamanan, pipa refrigeran, pamasangan unit luar ruangan, kabel, spésifikasi daya, evakuasi hawa, sareng prosedur uji coba.
Praview Manual Pamasangan Unit Luar Ruangan Sistem Inverter Sentral ACiQ
Manual pamasangan lengkep pikeun unit luar ruangan ACiQ Central Inverter Systems, anu ngawengku tindakan pencegahan kaamanan, pipa refrigeran, kabel, pamasangan unit, sareng prosedur uji coba pikeun modél sapertos ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB, sareng anu sanésna.
Praview ACiQ Ducted Air Handler Instalasi Manual (12K-60K BTU/h)
Manual instalasi ieu ti ACiQ nyadiakeun parentah lengkep pikeun instalasi aman tur bener tina Unit Ducted Air Handler, model 12K ngaliwatan 60K BTU / h. Éta nyertakeun pedoman kaamanan penting, panempatan unit, pipa refrigeran, kabel listrik, spésifikasi, sareng uji operasional pikeun mastikeun kinerja optimal sareng umur panjang sistem.
Praview ACiQ Extreme Heat Single-Zone Condenser & Concealed Duct Air Handler Instalasi Manual
Manual instalasi pikeun ACiQ Extreme Heat Single-Zone Condenser jeung Concealed Duct Air Handler sistem (model ACIQ-09CD-HH-MC mun ACIQ-60CD-HH-MC jeung ACIQ-09ZPL-HP230C mun ACIQ-60ZPL-HP230C). Ngawengku kaamanan, léngkah pamasangan, sareng spésifikasi.
Praview ACiQ Extreme+ Ducted Air Handler Owner's Manual
Comprehensive owner's manual for the ACiQ Extreme+ Ducted Air Handler (18K-60K), covering safety precautions, parts, maintenance, and troubleshooting.