1. Bubuka

Thank you for choosing the VEVOR SF-400D Analytical Lab Balance. This high-precision digital scale is designed for accurate and stable weighing results in various professional and personal settings. With a maximum capacity of 600g and a precision of 0.01g, it offers quick 3-second response times and multiple unit conversions. This manual provides essential information for the safe and efficient operation of your balance.

VEVOR 0.01g High Precision Lab Scale with 0.6kg max capacity and 3-second quick response

Image 1.1: VEVOR 0.01g High Precision Lab Scale, demonstrating its accuracy and quick response.

2. Parentah Kasalametan

3. Eusi Paket

Pastikeun yén sadaya item aya dina bungkusan:

4. Produk Langkungview

Familiarize yourself with the main components and controls of your analytical balance.

VEVOR Lab Balance LCD Display showing unit conversions (g, ct, dwt, gn, T, oz)

Image 4.1: LCD Display and Unit Conversion Options.

VEVOR Lab Balance showing dual power modes (AC 110V, DC 9V Battery) and user-friendly features

Image 4.2: Dual Power Modes and Key Features.

Panél kontrol:

Fitur séjén:

5. Setélan

5.1 Ngabongkar bungkusan

Sacara saksama miceun sadaya komponén tina bungkusan. Simpen bungkusan pikeun neundeun atanapi transportasi ka hareup.

5.2 Nempatkeun

Place the balance on a firm, level, and stable surface, away from drafts, vibrations, and direct heat or cold sources. Ensure adequate space around the balance for operation.

5.3 Ngaratakeun Kasaimbangan

For accurate measurements, the balance must be perfectly level.

  1. Locate the built-in leveling bubble, usually found near the display or on the side of the balance.
  2. Adjust the four adjustable feet at the bottom of the balance until the air bubble is centered within the circle of the leveling bubble indicator.
Close-up of the built-in leveling bubble and adjustable scale feet on the VEVOR Lab Balance

Image 5.1: Leveling Bubble and Adjustable Feet for precise setup.

5.4 Sambungan Daya

The balance supports dual power modes: AC adapter or batteries.

6. Parentah Operasi

6.1 Daya Hurung/Pareuman

Pencét éta ON/OFF button to turn the balance on. Press and hold the ON/OFF tombol salami sababaraha detik pikeun mareumanana.

6.2 Konversi Unit

Pencét éta MODÉ button repeatedly to cycle through the available weighing units: grams (g), carats (ct), pennyweights (dwt), grains (GN), taels (T), and ounces (oz).

6.3 Fungsi Tare

The tare function allows you to subtract the weight of a container, so only the net weight of the contents is displayed.

  1. Teundeun wadah kosong dina pan timbangan.
  2. Ngadagoan bacaan pikeun nyaimbangkeun.
  3. Pencét éta TAREUT button. The display will reset to zero.
  4. Tambahkeun barang anu bakal ditimbang kana wadahna. Pintonan bakal nunjukkeun beurat net barang.
Illustration of the full range tare function on the VEVOR Lab Balance

Image 6.1: Step-by-step guide for using the Tare Function.

6.4 Fungsi Ngitung (PCS)

This function is useful for counting a large number of uniform items.

  1. Tempat salakuample quantity of items (e.g., 10, 20, 50, or 100 pieces) on the weighing pan.
  2. Pencét jeung tahan tombol PCS button until a sample size option appears (e.g., "10 PCS").
  3. Pencét éta MODÉ tombol pikeun milih sample size that matches the number of items you placed.
  4. Pencét PCS again to confirm. The display will now show the count of the sample.
  5. Add more items to the pan, and the balance will display the total count.

6.5 Kalibrasi (CAL)

Regular calibration ensures the accuracy of your balance. A calibration weight (not included) is required.

  1. Ensure the balance is on a level surface and nothing is on the weighing pan.
  2. Pencét jeung tahan tombol KAL button until "CAL" appears on the display, followed by the required calibration weight (e.g., "600.00g").
  3. Carefully place the specified calibration weight onto the center of the weighing pan.
  4. The display will show "PASS" or a similar indication when calibration is complete. Remove the weight.
  5. The balance will return to normal weighing mode.

7. Pangropéa

7.1 beberesih

To maintain accuracy and prolong the life of your balance:

VEVOR Lab Balance with stainless steel tray highlighting rust-proof, corrosion-resistant, easy to clean, and longer lasting features

Image 7.1: High-Quality Materials for durability and easy cleaning.

7.2 Panyimpenan

When not in use, store the balance in a clean, dry, and stable environment. If storing for an extended period, remove batteries to prevent leakage.

8. Cara ngungkulan

If you encounter issues with your balance, refer to the following common problems and solutions:

Lamun masalah persists sanggeus nyobian solusi ieu, mangga ngahubungan rojongan customer VEVOR pikeun pitulung.

9. Spésifikasi

Detailed technical specifications for the VEVOR SF-400D Analytical Lab Balance:

VEVOR Lab Balance specifications including model number, voltage, power source, unit types, display, error, response time, max weighing, display accuracy, product weight, and dimensions.

Image 9.1: VEVOR Lab Balance Specifications.

FiturSpésifikasi
Nomer modélSF-400D
Dipeunteun Voltage5V
Sumber DayaAC Adapter + Battery Supported
Jinis Unit6 (g, ct, dwt, GN, T, oz)
tampilanLCD
Error / Precision± 0.01g
Waktu Tanggapan3 Detik
Max Weighing Capacity0.6 kg (600g)
Témbongkeun Akurasi0.01g
Beurat produk1.26 pon / 0.57 kg
Ukuran produk (L x W x H)8.07 x 6.30 x 2.36 inci / 205 x 160 x 60 mm
BahanPlastic, Stainless Steel, Metal

10. Garansi jeung Rojongan

Kanggo inpormasi garansi, dukungan téknis, atanapi patarosan jasa, mangga tingal kartu garansi anu kalebet dina produk anjeun atanapi kunjungan ka VEVOR resmi. websitus. Simpen resi pameseran anjeun salaku bukti pameseran.