Reznor UDXC-150

Pemanas Unit Gas Alam Reznor UDXC-150: Manual Pamasangan sareng Operasi

Model: UDXC-150 | Brand: Reznor

1. Bubuka

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Reznor UDXC-150 Natural Gas Unit Heater. Please read all instructions carefully before attempting to install or operate the unit. Retain this manual for future reference.

Hareupeun view of the Reznor UDXC-150 Natural Gas Unit Heater.

Gambar 1: Hareupeun view of the Reznor UDXC-150 Natural Gas Unit Heater. This image displays the front and side view of the Reznor UDXC-150 Natural Gas Unit Heater, showcasing its compact design and air outlet.

2. Émbaran Kasalametan

PERHATOSAN: Pamasangan, panyesuaian, parobahan, palayanan, atanapi pangropéa anu teu leres tiasa nyababkeun karusakan harta, tatu, atanapi maot. Baca paréntah pamasangan, operasi, sareng pangropéa sacara saksama sateuacan masang atanapi ngalayanan alat ieu.

  • Ensure all local codes and ordinances are followed during installation.
  • Pamasangan sareng palayanan kedah dilakukeun ku pamasang, agénsi jasa, atanapi supplier gas anu mumpuni.
  • Entong nyimpen atanapi nganggo béngsin atanapi uap sareng cairan anu gampang kaduruk di sakuriling ieu atanapi alat anu sanés.
  • Unit ieu dirancang pikeun panggunaan jero rohangan hungkul.

3. Setup jeung Instalasi

The Reznor UDXC-150 unit heater is designed for versatile installation in commercial or industrial spaces. Proper setup is crucial for safe and efficient operation.

3.1 Pamasangan

The UDXC-150 is equipped with threaded-nut retainers at four suspension points, allowing for ceiling or wall mounting. Mounting brackets and hardware are sold separately and must be appropriate for the unit's weight and the structural integrity of the mounting surface.

Reznor UDXC-150 Unit Heater mounted on a ceiling, with a list of standard features.

Figure 2: Ceiling-mounted Reznor UDXC-150 Unit Heater. The heater is shown installed on a ceiling, illustrating its suspension points. Accompanying text lists features such as Status-Indicating LED Light, 7-Segment Display Board for troubleshooting, 2- and 4-Point Suspension Options, External Gas Connection, and ETL Approval.

3.2 Ngubaran

This unit is compatible with category 1 double wall B-vent pipe. Venting can be configured vertically out of a roof or horizontally through a sidewall. Consult local codes for specific venting requirements.

3.3 Sambungan Gas

An external gas connection point is provided for ease of maintenance and installation. Ensure all gas connections are leak-free and comply with local regulations. This unit operates on Natural Gas.

3.4 Kabel Listrik

The unit features an external terminal strip for 24V wiring. All electrical work must be performed by a qualified electrician and adhere to all applicable electrical codes.

Image showing a worker installing a Reznor unit heater, with text about compact and durable heating.

Figure 3: Installation of the Reznor UDXC-150 Heater. A worker is shown connecting ductwork to a ceiling-mounted heater. The text emphasizes the unit's suitability for commercial/industrial spaces, corrosion-resistant materials, and quiet, efficient heating.

4. Parentah Operasi

The Reznor UDXC-150 is designed for efficient and quiet heating.

4.1 Mimiti Mimiti

  1. Ensure all gas and electrical connections are secure and verified by a professional.
  2. Hurungkeun suplai gas ka unit.
  3. Mulangkeun kakuatan listrik kana unit.
  4. Set the thermostat to the desired temperature. The unit will initiate its ignition sequence.

4.2 Operasi normal

  • The unit features a single-burner design with two BTU outputs, allowing for efficient heating in varying conditions.
  • An integrated circuit board with a display and a status-indicating LED provides operational feedback.
  • The low static pressure axial fan and power venting system ensure effective air circulation and minimize heat loss.
  • The unit operates with low noise due to vibration-isolated fan and venter motors.
Graphic detailing standard features of the Reznor UDXC-150 Unit Heater.

Figure 4: Key Features of the Reznor UDXC-150 Unit Heater. This graphic highlights key features including 83% AFUE Efficiency, TCORE2 Titanium-Stabilized Aluminized Steel Heat Exchanger, Multi-Try Direct Spark Ignition, and Low Noise Operation.

5. Pangropéa

Regular maintenance ensures the longevity and optimal performance of your Reznor UDXC-150 unit heater. All maintenance should be performed by qualified personnel.

5.1 Routine Checks (Monthly/Quarterly)

  • Inspect the heat exchanger for any signs of corrosion or damage. The TCORE2 titanium-stabilized aluminized steel heat exchanger is designed for durability.
  • Check the fan and motor for unusual noises or vibrations.
  • Ensure the air intake and exhaust vents are clear of obstructions.
  • Verify that the external gas connection is secure and free of leaks.

5.2 Annual Servicing

  • A qualified technician should perform a comprehensive inspection and cleaning of the burner, heat exchanger, and ignition system.
  • The updated cabinet structure with a removable front face and hinged access door panel with a quarter-turn latch facilitate easier access for servicing.
  • Check and calibrate gas pressure as needed.
  • Inspect all electrical connections and wiring.

6. Cara ngungkulan

The UDXC-150 unit heater includes features to assist with troubleshooting common issues.

MasalahMungkin Cukang lantarananaSolusi
Heater does not igniteNo gas supply, electrical issue, ignition faultCheck gas valve, power supply. Consult 7-segment display for error codes.
Unit runs but no heatGas supply interrupted, burner issueVerify gas flow. Check burner for obstructions.
Noise mahiwal salila operasiFan imbalance, motor issue, loose componentsInspect fan and motor. Tighten any loose parts. If persistent, contact service.
Status LED indicates an errorSpecific fault detected by the control boardRefer to the 7-segment display board for specific error codes and consult the full service manual for detailed troubleshooting steps.

For complex issues or if the problem persists, contact a qualified service technician.

7. Spésifikasi

FiturRincian
Nomer modélUDXC-150
Kaluaran Panas150,000 British Thermal Units (BTU)
Tipe SuluhGas alam
Éféktivitas termal83%
Ukuran produk (D x W x H)48.44" x 38.19" x 20.13"
Tipe PamasanganCeiling Mount, Wall Mount (brackets sold separately)
Tipe KamarGarage, Warehouse, Commercial/Industrial Spaces
Fitur hususEnergy Efficient, Fast Heating, Low Noise Operation, TCORE2 Titanium-Stabilized Aluminized Steel Heat Exchanger, 7-Segment Display Board
Jumlah Speeds2
Diagram showing the dimensions of the Reznor UDXC-150 Unit Heater.

Figure 5: Dimensions of the Reznor UDXC-150 Unit Heater. This image provides the physical dimensions of the 150,000 BTU unit, including its width, depth, and height, essential for installation planning.

8. Video produk

Taya video produk resmi ti seller kapanggih dina data disadiakeun pikeun embedding di manual ieu.

9. Émbaran jaminan

Specific warranty details for the Reznor UDXC-150 unit heater are typically provided at the point of purchase or included with the product packaging. Please refer to the warranty card or contact the seller (1HVAC) or Reznor directly for comprehensive warranty terms and conditions.

10. Rojongan jeung Kontak

For technical assistance, parts, or service inquiries, please contact the seller or an authorized Reznor service provider. Ensure you have your model number (UDXC-150) and serial number available when contacting support.

Seller: 1HVAC

Kanggo inpo tambahan, anjeun tiasa nganjang ka 1HVAC Store on Amazon.

Two Reznor unit heaters, one with a fan visible, and text about product condition and packaging.

Figure 6: Product Condition and Packaging. This image shows two unit heaters, one from the front and one from the side revealing the fan. Text describes the careful handling in the 1HVAC warehouse and expert packaging to ensure product integrity during transit.

Dokumén Patali - UDXC-150

Praview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Praview Reznor siling gantung Kit Instalasi Guide pikeun Electric jeung Gas-dipecat Unit pamanas
parentah instalasi tur rinci komponén pikeun Reznor CK22 siling gantung Kit, cocog sareng EHU listrik sarta UDXC, UDX, UDZ gas-dipecat Unit pamanas. Diajar kumaha carana masang manaskeun Reznor anjeun aman.
Praview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)
Comprehensive installation guide for Reznor CL31 and CL32 relay kits, enabling multiple unit control for various Reznor electric and gas-fired heaters. Includes component lists, detailed installation steps, and wiring specifications.
Praview Pituduh Instalasi Kit Reznor Vertical Louver pikeun Pemanas Unit Dipecat Gas (OPT-CD1)
Parentah instalasi pikeun Reznor OPT-CD1 nangtung Louver Kit, dirancang pikeun pamanas Unit gas-dipecat (model UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Ngawengku daptar komponén sareng pituduh rakitan léngkah-léngkah.
Praview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.
Praview Reznor Heat Exchanger Gasket Kit Installation Guide for Gas-Fired Unit Heaters
Detailed installation instructions for Reznor heat exchanger gasket kits for UBX, UBXC, UBZ, UDX, UDXC, and UDZ gas-fired unit heaters. Includes kit components, sizes, and step-by-step installation procedures.