Reznor UDXC-150

Buku Panduan Pemanas Unit Gas LP Reznor UDXC-150 150,000 BTU

model: UDXC-150 | merek: Reznor

Émbaran Kasalametan penting

Read and understand all instructions before installing, operating, or servicing this unit heater. Failure to follow these instructions could result in property damage, personal injury, or death.

  • Kasalametan Gas: This unit uses LP (Liquid Propane) gas. Ensure all gas connections are properly sealed and tested for leaks. Installation must comply with local codes and national standards.
  • Kasalametan listrik: Ensure the unit is properly grounded and connected to the correct power supply as specified. Disconnect power before servicing.
  • Ventilasi: Proper venting is crucial to prevent carbon monoxide poisoning. Ensure the exhaust system is correctly installed and maintained.
  • Pamasangan: Only qualified personnel should install and service this appliance. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
  • Proposisi 65 Peringatan: Produk ieu tiasa ngalaan anjeun ka bahan kimia kalebet timah, anu dipikanyaho ku Nagara California nyababkeun kanker sareng cacad kalahiran atanapi cilaka réproduktif sanés. Kanggo inpo nu leuwih lengkep buka www.P65Warnings.ca.gov.

Produk Leuwihview

The Reznor UDXC-150 is a 150,000 BTU LP Gas Unit Heater designed for commercial and industrial applications such as garages, workshops, warehouses, and factories. It features a forced-air design with a low static propeller fan for efficient heat distribution.

Reznor UDXC-150 LP Gas Unit Heater

Gambar: Hareupeun view of the Reznor UDXC-150 LP Gas Unit Heater.

Fitur konci:

  • Propane Compatibility: Designed for LP gas, suitable for various indoor commercial or industrial settings.
  • Kinerja luhur: 150,000 BTU output with two heating levels (low fire 87,150 BTU / high fire 124,500 BTU) and 83% thermal efficiency.
  • Pamasangan Versatility: Threaded-nut retainers at four suspension points allow for ceiling or wall mounting (mounting hardware sold separately).
  • Konstruksi awét: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger.
  • Kadali canggih: Patented single-burner combustion, integrated circuit board with display, built-in disconnect, and current status LED for diagnostics.

Spésifikasi teknis

FiturSpésifikasi
merekReznor (1HVAC)
Nomer modélUDXC-150 | 1043187R
Kaluaran Panas150,000 British Thermal Units (BTU)
Tipe SuluhLiquid Propane (LP Gas) - Convertible from Natural Gas
Éféktivitas termal83%
Jumlah Speeds2 (Low Fire: 87,150 BTU / High Fire: 124,500 BTU)
Ampumur11 Amps
Dimensi produk48.88 "D x 41" W x 34.13" H
Tipe PamasanganCeiling Mount / Wall Mount (Mounting hardware sold separately)
Pamakéan jero rohangan / outdoorjero rohangan
Fitur hususPemanasan gancang
Penukar PanasTCORE2 Titanium-Stabilized Aluminized Steel
Reznor UDXC-150 Unit Heater Dimensions

Image: Diagram showing the dimensions of the Reznor UDXC-150 unit heater.

Setup sareng Instalasi

Proper installation is critical for the safe and efficient operation of your Reznor UDXC-150 unit heater. Consult a qualified HVAC professional for installation to ensure compliance with all local and national codes.

Cék Pra-Pasang:

  • Verify that the unit's BTU output is appropriate for the space to be heated.
  • Ensure adequate clearance from combustible materials as specified in the installation manual.
  • Confirm that the gas supply (LP) and electrical supply meet the unit's requirements.
  • If converting from natural gas to LP, ensure the provided LP conversion kit is correctly installed by a qualified technician.

Pamasangan:

The UDXC-150 can be ceiling-mounted or wall-mounted using appropriate brackets (sold separately). The unit includes threaded-nut retainers at four suspension points for secure attachment.

Reznor UDXC-150 Unit Heater Ceiling Mounted

Image: Reznor UDXC-150 unit heater installed and suspended from a ceiling, highlighting its mounting options.

Sambungan Gas sareng Listrik:

  • Connect the LP gas supply line to the unit, ensuring all connections are tight and leak-free.
  • Wire the unit to the electrical supply according to the wiring diagram in the full installation manual. This includes connections for the fan, combustion blower, and integrated circuit board.

Venting:

The unit is compatible with Category I double-wall B-vent pipe for vertical or horizontal venting. Ensure the vent pipe is properly sized, installed, and sealed to safely exhaust combustion byproducts.

Parentah Operasi

Once installed and all connections are verified, follow these steps to operate your Reznor UDXC-150 unit heater:

  1. Daya Hurung: Ensure the main electrical supply to the unit is switched on.
  2. Pasokan Gas: Open the manual gas shut-off valve to allow LP gas to flow to the unit.
  3. Setélan termostat: Set the thermostat to your desired temperature. The unit will automatically cycle on and off to maintain this temperature.
  4. Heat Output Selection: The UDXC-150 offers two heat output levels. Refer to the full manual for instructions on how to select between low fire (87,150 BTU) for milder conditions and high fire (124,500 BTU) for colder periods.
  5. Mimitian mimiti: Upon initial startup or after a prolonged shutdown, it may take a few minutes for the gas lines to purge air, and the unit may attempt ignition multiple times before successfully lighting.
  6. Pareuman: To turn off the unit, lower the thermostat setting below the ambient temperature or switch off the main electrical supply. For extended shutdowns, close the manual gas shut-off valve.
Reznor UDXC-150 Heating Flexibility

Image: Graphic illustrating the heating flexibility of the Reznor UDXC-150 with its dual BTU output for varying temperatures.

Pangropéa

Regular maintenance ensures the longevity and efficient operation of your unit heater. Perform the following checks periodically:

  • Inspeksi taunan: Have a qualified service technician inspect the unit annually, preferably before the heating season.
  • Kabersihan: Keep the area around the heater clear of debris and obstructions. Ensure the air intake and discharge grilles are clean.
  • Pamariksaan Sistem Ventilasi: Inspect the vent pipe for any signs of corrosion, leaks, or blockages.
  • Inspeksi komponén: Check electrical connections for tightness and signs of wear. Inspect the fan and motor for proper operation and lubrication if required.

Pamérésan masalah

If your Reznor UDXC-150 unit heater is not operating correctly, refer to the following common issues before contacting a service technician:

  • No Heat/Unit Not Starting:
    • Check if the electrical power supply is on.
    • Pastikeun klep suplai gas kabuka.
    • Verify the thermostat is set above the ambient temperature.
    • Check the unit's integrated circuit board display and status LED for diagnostic codes. Refer to the full manual for code interpretations.
  • Panas teu cekap:
    • Confirm the unit is operating on the high fire setting if maximum heat is desired.
    • Ensure no obstructions are blocking the air intake or discharge.
    • Check for proper ventilation and insulation of the heated space.
  • Noises atawa Bau mahiwal:
    • Immediately shut off the gas supply and electrical power.
    • Do not attempt to operate the unit. Contact a qualified service technician.

For detailed troubleshooting steps and error code explanations, consult the complete installation and operation manual provided with your unit.

Garansi sareng Rojongan

This Reznor UDXC-150 unit heater is backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Reznor customer support.

If you require technical assistance, parts, or service, please contact the authorized dealer or service center where you purchased the unit. Ensure you have your model number (UDXC-150) and serial number available when contacting support.

For general inquiries or to locate an authorized service provider, visit the official Reznor website or contact 1HVAC, the brand associated with this product.

Dokumén Patali - UDXC-150

Praview Reznor siling gantung Kit Instalasi Guide pikeun Electric jeung Gas-dipecat Unit pamanas
parentah instalasi tur rinci komponén pikeun Reznor CK22 siling gantung Kit, cocog sareng EHU listrik sarta UDXC, UDX, UDZ gas-dipecat Unit pamanas. Diajar kumaha carana masang manaskeun Reznor anjeun aman.
Praview Reznor Gas Conversion Kit Installation for Gas-Fired Unit Heaters
This document provides installation instructions for Reznor gas conversion kits for various gas-fired unit heater models, including UBX, UBXC, UBZ, UDX, UDXC, UDZ, UDAP, UDAS, UDBP, and UDBS. It details component selection, safety precautions, and installation steps for converting between natural gas and propane, as well as for high-elevation installations.
Praview Reznor Relay Kit Installation Guide for Multiple Unit Control (CL31/CL32)
Comprehensive installation guide for Reznor CL31 and CL32 relay kits, enabling multiple unit control for various Reznor electric and gas-fired heaters. Includes component lists, detailed installation steps, and wiring specifications.
Praview Pamasangan Kit Gantung Ceiling Reznor pikeun Pemanas Unit Listrik sareng Gas (Pilihan CK22)
Pituduh pamasangan pikeun Reznor CK22 Ceiling Suspension Kit, dirancang pikeun EHU, UDX, UDXC, sareng UDZ listrik sareng pamanas unit gas. Ngawengku komponén kit sareng léngkah pamasangan.
Praview Pituduh Instalasi Kit Reznor Vertical Louver pikeun Pemanas Unit Dipecat Gas (OPT-CD1)
Parentah instalasi pikeun Reznor OPT-CD1 nangtung Louver Kit, dirancang pikeun pamanas Unit gas-dipecat (model UBX, UBXC, UBZ, UDX, UDXC, UDZ, UEZ). Ngawengku daptar komponén sareng pituduh rakitan léngkah-léngkah.
Praview Reznor UBXC/UDXC Gas-Fired Unit Heater Replacement Parts Manual
This manual provides detailed replacement parts information for Reznor UBXC and UDXC series gas-fired unit heaters. It includes sections on serial number decoding, electrical components, fan and motor assemblies, blower assemblies, cabinet components, heat exchanger and burner assemblies, venter and flue wrapper components, and various accessories and options.