1. Bubuka
This manual provides instructions for the safe and efficient operation of your Jebao Jecod EP-10000M Smart DC Pump. This pump is designed for use in both marine and freshwater aquarium systems, offering precise control via an LCD display controller and 2.4G Wi-Fi connectivity through the Jebao App.

Image 1.1: The Jebao Jecod EP-10000M Smart DC Pump with its retail packaging.
2. Émbaran Kasalametan
Please read all safety warnings and instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Kasalametan listrik: Ensure the power supply matches the pump's requirements (24V DC). Always disconnect power before performing any maintenance or installation.
- Kontak cai: The pump is designed for submersible use. Ensure all electrical connections are dry and away from water. There are no exposed copper elements, making it suitable for both marine and fresh water environments.
- Perlindungan otomatis: The pump features IC electronic detection for automatic power-off protection if no water is detected. It also includes motor protection if the rotor becomes blocked. Do not bypass these safety features.
- panempatan: Position the pump securely to prevent accidental movement or damage.
3. Eusi Paket
Pastikeun yén sadaya komponén aya dina bungkusan:
- Jebao Jecod EP-10000M DC Pump
- LCD Display Controller
- Power Adapter (110-120V 60Hz input, 24V DC output)
- Various hose connectors/fittings
- O-cingcin
- Manual Pitunjuk (dokumén ieu)

Image 3.1: All included components: pump, controller, power adapter, and various fittings.
4. Setélan
Follow these steps to set up your EP-10000M pump:
- Nyiapkeun Pompa: Attach the appropriate hose connectors/fittings to the pump's inlet and outlet. Ensure O-rings are correctly seated for a watertight seal.
- Pasang Pompa: Place the pump in your desired location within the aquarium or sump. Ensure it is fully submerged if intended for submersible operation.
- Nyambung ka Controller: Connect the pump's cable to the LCD display controller. Ensure the connection is secure.
- Sambungkeun Adaptor Daya: Connect the power adapter to the LCD display controller.
- Daya Hurung: Plug the power adapter into a suitable electrical outlet. The LCD display should illuminate.
- Sambungan Wi-Fi (Opsional):
- Download the Jebao App from your smartphone's app store (iOS or Android).
- Follow the in-app instructions to connect the pump to your 2.4G Wi-Fi network. The controller also supports AP (Access Point) mode, allowing direct connection without a router if needed.

Image 4.1: The pump with an output adapter installed, ready for hose connection.
5. Parentah Operasi
The EP-10000M pump offers flexible control options:
- LCD Display Controller: Use the buttons on the LCD controller to adjust flow rate, switch modes, and access settings. Refer to the controller's specific interface for detailed button functions.
- Jebao App: Once connected via Wi-Fi, the Jebao App provides comprehensive control over the pump's functions, including scheduling, power adjustments, and mode selection.
- SINE Wave Technology: This pump utilizes SINE wave technology for ultra-quiet operation and stable performance, minimizing noise and vibrations in your aquarium system.

Gambar 5.1: A lengkep view of the pump's intake section, highlighting its design.
6. Pangropéa
Pangropéa rutin ngajamin kinerja optimal sareng umur panjang pompa anjeun.
- Pegatkeun Daya: Salawasna cabut pompa tina sumber listrik sateuacan aya pangropéa.
- Pembersihan Rotor: Periodically remove the pump's front cover and impeller assembly. Clean the impeller and its housing to remove any debris, algae, or calcium buildup. A small brush can be used.
- Bersihan Perumahan: Wipe down the pump's exterior and controller with a damp lawon. Ulah make bahan kimia kasar.
- Pamariksaan kabel: Regularly inspect the power cable and pump cable for any signs of damage or wear. Replace if necessary.
- Reassembly: Ensure all parts are correctly reassembled and seals are properly seated before reconnecting power.
7. Cara ngungkulan
If you encounter issues with your EP-10000M pump, refer to the following common problems and solutions:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pompa teu jalan | No power; blocked impeller; no water detected (safety shutdown) | Check power connection; clean impeller; ensure pump is submerged and water level is adequate. |
| Laju aliran ngurangan | Clogged impeller or intake; kinked tubing; incorrect setting | Clean impeller and intake; check tubing for obstructions; adjust flow setting on controller/app. |
| Noise/geter mahiwal | Debris in impeller; worn impeller; pump not securely placed | Clean impeller; inspect impeller for damage (replace if necessary); ensure pump is stable. |
| Masalah sambungan Wi-Fi | Incorrect Wi-Fi password; 5Ghz network; distance from router; app issues | Ensure 2.4Ghz network is used; re-enter password; move closer to router; restart app/controller. |
8. Spésifikasi
Technical specifications for the Jebao Jecod EP-10000M Smart DC Pump:
| Fitur | Spésifikasi |
|---|---|
| Modél | EP-10000M |
| Laju Aliran Max | 2641 GPH (10000 L/H) |
| Kepala Max | 19.7 ft (6.0 m) |
| Konsumsi Daya | 80W |
| Masukan Voltage | 110-120V, 60Hz (for power adapter) |
| Kaluaran Voltage | DC 24V (to pump) |
| Ukuran (L x W x H) | 8 x 4 x 5 inches (approximate pump dimensions) |
| Bahan | Plastik, Polipropilén (PP) |
| Warna | Bodas |
| Beurat | 7 pounds (item weight) |
| Konektipitas | 2.4G Wi-Fi, AP Mode, Manual Controller |
| Jenis Cai | Marine and Fresh Water |
| Panyalindungan | IC electronic detection, automatic power-off (no water), motor protection (rotor blocked) |
9. Garansi jeung Rojongan
For warranty information and customer support, please refer to the documentation provided with your purchase or contact Jebao customer service directly. Specific warranty terms may vary by region and retailer.