1. Parentah Kasalametan
Read all safety warnings and instructions carefully before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Salawasna pegatkeun sambungan pompa tina catu daya sateuacan ngalaksanakeun pangropéa atanapi beberesih naon waé.
- Pastikeun catu daya voltage cocog spésifikasi pompa urang (230V).
- Do not operate the pump with a damaged power cord or plug. If damaged, contact qualified personnel for repair.
- Never lift or carry the pump by its power cord. Use the integrated handle.
- Jauhkeun barudak sareng jalma anu henteu sah tina pompa operasi.
- The pump is designed for pumping water only. Do not use it for flammable, corrosive, or explosive liquids.
- Pastikeun pompa pinuh submerged salila operasi pikeun nyegah overheating.
- The pump is rated IPX8 for water resistance, suitable for continuous submersion.
2. Produk Langkungview
The VEVOR 3.0HP/2200W Submersible Sump Pump is designed for efficient drainage of clean and dirty water from various locations such as basements, pools, hot tubs, and garden ponds. It features a robust construction and an automatic float switch for hands-free operation.

Image: The VEVOR submersible pump is suitable for multiple applications, including draining flooded areas, pools, and ponds.
Fitur konci:
- Kinerja anu kuat: Equipped with a 2200W (3 HP) motor, capable of pumping up to 1000 liters per minute (60,000 L/hour) and lifting water vertically up to 18 meters (60 feet).
- Konstruksi awét: Features a corrosion-resistant cast iron base and a sturdy stainless steel body for long-lasting use in submerged conditions. It holds an IPX8 waterproof rating and CE certification.
- Operasi otomatis: An integrated tethered float switch automatically starts and stops the pump based on water levels, providing convenient, hands-free drainage.
- Drainase efisien: Designed with a 7.6 cm (3 inch) discharge outlet for high flow rates and can pass solids up to 2 cm (0.8 inch) in diameter.
- Desain anu ramah-pamaké: Includes a 10-meter (33 feet) waterproof power cord and an ergonomic handle for easy transport and connection.

Image: Visual representation of the pump's powerful performance metrics and features like ultra-quiet operation and overload protection.

Image: Breakdown of the pump's corrosion-proof materials and durable components, including the IPX8 waterproof rating.
3. Spésifikasi
| Spésifikasi | Nilai |
|---|---|
| Modél | 3.0HP Sump Pump |
| Kakuatan | 2200W / 3 HP |
| Voltage | 230V (220-240V 50/60Hz) |
| Max. Laju Aliran | 1000 L/min (60,000 L/hour / 264 GPM) |
| Max. Angkat Jangkungna | 18 m (60 ft) |
| Max. Jero Submersion | 10 m (33 ft) |
| Max. Solid Passage | 2 cm (0.8 inci) |
| Diaméter Outlet Pembuangan | 7.6 cm (3 inci) |
| Rentang Suhu Cai | 0-40°C (32-104°F) |
| Jenis panyalindungan | IPX8 |
| Panjang kabel kakuatan | 10 m (33 ft) |
| Ukuran produk (L x W x H) | 30 x 20 x 52 cm (11.8 x 7.9 x 20.5 inci) |
| Beurat produk | 25.9 kg |
| Bahan | beusi tuang, stainless steel |

Image: Detailed specifications and dimensional overview of the VEVOR sump pump.
4. Setélan
4.1 Ngabongkar sareng Inspeksi
- Sacara saksama cabut pompa sareng sadaya asesoris tina bungkusan.
- Inspect the pump for any signs of damage during transit. Do not use if damaged.
- Pastikeun yén sadaya komponén anu didaptarkeun dina bungkusan aya.
4.2 Connecting the Discharge Hose
- Attach a suitable discharge hose (with a 7.6 cm / 3 inch diameter) to the pump's outlet. Secure it firmly with a hose clamp (not included) to prevent leaks.
- Ensure the hose is routed without kinks or sharp bends to maintain optimal flow.
4.3 Positioning the Pump
- Place the pump on a stable, level surface in the area to be drained. Avoid placing it directly on soft mud or sand, which could block the intake.
- Ensure the pump is fully submerged in water before operation. The maximum submersion depth is 10 meters (33 feet).
4.4 Adjusting the Float Switch
- The float switch controls the automatic on/off function of the pump. Adjust the length of the float switch cable to set the desired water levels for activation and deactivation.
- A shorter cable length will result in the pump activating at a lower water level and deactivating sooner. A longer cable length will allow the water level to rise higher before activation and drain more water before deactivation.
- Ensure the float switch can move freely without obstruction.

Image: Installation guide illustrating maximum submersion depth, acceptable water temperature, solid particle size, power cord length, and discharge diameter.
5. Parentah Operasi
5.1 Operasi otomatis
- Once the pump is positioned and the discharge hose is connected, plug the power cord into a grounded electrical outlet (230V).
- Pompa bakal otomatis hurung nalika tingkat cai naék sareng ngangkat saklar pelampung.
- The pump will automatically stop when the water level drops and the float switch falls to its lower position.
- Ensure the water temperature remains within the specified range of 0-40°C (32-104°F).

Image: Explanation of the automatic tethered float switch operation, showing pump activation and deactivation based on water level.
5.2 Manual Operation (if applicable)
While the pump is primarily designed for automatic operation via the float switch, ensure the float switch is always free to move. For continuous pumping, the float switch must remain in the 'on' (floating) position. However, continuous manual monitoring is recommended to prevent dry running.
6. Pangropéa
Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect power before maintenance.
6.1 Ngabersihkeun Pompa
- Periodically clean the pump's intake screen to remove debris, leaves, or other particles that may obstruct water flow.
- Rinse the pump with clean water after use, especially if pumping dirty or muddy water.
6.2 Inspecting komponén
- Check the power cord and plug for any signs of damage, cuts, or fraying. Replace if necessary.
- Ensure the float switch moves freely and is not obstructed by debris.
- Inspect the discharge outlet and impeller area for any blockages.
6.3 Winterization (pikeun iklim tiis)
- If the pump is used in an area where temperatures drop below freezing, remove it from the water before winter.
- Clean the pump thoroughly and store it in a dry, frost-free location.
7. Cara ngungkulan
Before attempting any repairs, always disconnect the pump from the power supply.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pompa teu ngamimitian | Taya catu daya Saklar ngambang teu diaktipkeun Perlindungan overload termal diaktipkeun Kasalahan motor | Pariksa sambungan kakuatan sarta circuit breaker Ensure water level is high enough to lift float switch Allow pump to cool down; check for blockages Contact VEVOR support |
| Pump runs but no water is pumped | Intake screen blocked Discharge hose kinked or blocked Konci hawa Impeller ruksak | Clean intake screen Clear obstructions from hose Lift and lower pump slightly to release air Contact VEVOR support |
| Laju aliran ngurangan | Partial blockage in intake or discharge Pompa teu pinuh submerged Excessive lift height or hose length | Clean intake screen and check hose Ensure pump is adequately submerged Verify installation meets specifications |
| Ngompa siklus teuing | Ngambang switch adjustment Small volume of water being drained | Adjust float switch cable length to increase on/off differential This may be normal for small water volumes |
8. Garansi jeung Rojongan
For warranty information, technical support, or spare parts inquiries, please contact VEVOR customer service. Refer to your purchase documentation for specific warranty terms and contact details.
Note: Information regarding spare parts availability is not provided in the product specifications.