1. Bubuka
This manual provides detailed instructions for the safe and effective use of the GYS 059856 Paint Thickness Gauge. This portable device is designed for quick and easy measurement of non-magnetic coatings (such as paint or film) on metallic surfaces. It is an essential tool for various applications including the processing industry, automotive repair, metal treatment, chemical industry, and goods inspection.
Punten baca manual ieu sacara saksama sateuacan ngoperasikeun alat sareng jaga pikeun rujukan ka hareup.
2. Émbaran Kasalametan
- Always ensure the device is clean and dry before use.
- Ulah ngalaan alat ka suhu ekstrim, kalembaban, atawa sinar panonpoé langsung.
- Hindarkeun ragrag atanapi ngagentoskeun alat kana tabrakan anu kuat.
- Ulah nyobian ngabongkar atawa ngalereskeun alat sorangan. Rujuk ka tanaga anu mumpuni pikeun jasa.
- Jauhkeun alat tina jangkauan barudak.
- Buang batré sacara tanggung jawab nurutkeun peraturan lokal.
3. Produk Langkungview
The GYS 059856 Paint Thickness Gauge features a compact design with an LCD display and intuitive controls.

Gambar 1: Hareupeun view of the GYS 059856 Paint Thickness Gauge. The device is yellow with a black LCD screen at the top. Below the screen are three black buttons: 'MODE' on the left, 'UNIT' on the right, and 'ZERO' with a power symbol in the center bottom.
3.1 Komponén konci
- Layar LCD: Shows measurement readings, units, and mode indicators.
- Tombol MODE: Used to switch between measurement modes (Single, Continuous, Differential).
- Tombol UNIT: Used to switch between metric (µm) and imperial (mils) units.
- Tombol ZERO: Used for zero calibration and powering the device on/off.
- Probe Pangukuran: Located at the bottom of the device, used to contact the surface for measurement.
4. Setélan
4.1 Pamasangan batré
Locate the battery compartment on the back of the device. Insert the required batteries, ensuring correct polarity. Close the battery compartment securely.
4.2 Powering on / Pareum
Pencét jeung tahan tombol NOL button to power on the device. To power off, press and hold the NOL button again. The device also features an automatic shut-off function to conserve battery life.
5. Parentah Operasi
The GYS 059856 offers three measurement modes and supports both metric and imperial units.
5.1 Selecting Measurement Units
Pencét éta UNIT button to toggle between metric (µm) and imperial (mils) units.
5.2 Modeu pangukuran
Pencét éta MODÉ tombol pikeun ngaliwat modeu pangukuran ieu:
- Single Measurement Mode: Takes a single reading each time the probe is placed on the surface.
- Continuous Measurement Mode: Continuously takes readings as the probe is moved across the surface.
- Differential Measurement Mode: Displays the difference between the current reading and a previously set reference value.
5.3 Nyandak Pangukuran
- Ensure the surface to be measured is clean and free of debris.
- Select the desired measurement unit and mode.
- Place the measurement probe firmly and perpendicularly onto the coated metallic surface.
- Read the thickness value displayed on the LCD screen.
- Lift the device from the surface to prepare for the next measurement (in Single mode).
6. Kalibrasi
Accurate measurements depend on proper calibration. The device supports three calibration functions:
6.1 Nol Calibration
This calibration is performed on an uncoated, bare metallic surface to establish a zero reference point. Place the probe on a clean, uncoated metal surface and follow the on-screen instructions or refer to the device's specific calibration sequence (usually involving the NOL tombol).
6.2 Dua-titik Calibration
This method uses two known thickness standards (e.g., a thin film and a thicker film) to calibrate the device across a range. This provides more accurate readings for varying thicknesses.
6.3 Easy Calibration
Refer to the device's specific instructions for "Easy Calibration," which may involve a simplified process for quick adjustments.
Note: Always calibrate the device before critical measurements or if you suspect inaccurate readings.
7. Pangropéa
- beberesih: Ngusap alat ku kaén anu lemes sareng garing. Ulah make cleaners abrasive atawa pangleyur.
- Panyimpenan: Store the device in a dry, cool place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries.
- Perawatan Probe: Keep the measurement probe clean and free from scratches or damage.
8. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Alat teu hurung. | batré lemah atawa maot; polaritasna batré salah. | Ganti batré; pariksa orientasi batré. |
| Bacaan teu akurat. | Device not calibrated; dirty probe; surface not clean; incorrect measurement mode. | Perform calibration; clean probe and surface; select appropriate measurement mode. |
| Layar nunjukkeun "OL" atanapi "Err". | Measurement range exceeded; sensor error. | Ensure measurement is within device's range; restart device. If error persists, contact support. |
9. Spésifikasi
- model: GYS 059856
- Pabrikan: GYS
- Ukuran produk (L x W x H): 10.5 x 6.1 x 2.8 cm
- beurat: 137 gram
- Prinsip pangukuran: Non-magnetic coating on metallic surfaces
- Unit ukur: Metric (µm), Imperial (mils)
- Modeu pangukuran: Single, Continuous, Differential
- Calibration Functions: Zero calibration, 2-point calibration, Easy calibration
- Pareuman otomatis: Sumuhun
- ASIN: B09GS7G1N4
- Rujukan Pabrikan: 059856
- Kasadiaan suku cadang: Inpormasi henteu sayogi
10. Garansi jeung Rojongan
For warranty information and technical support, please refer to the official GYS website or contact your local distributor. Information regarding spare parts availability is not provided in the product specifications.
GYS Official Websitus: www.gys.fr