Leviton DOS05-1LZ

Saklar Lampu Sensor Gerak Leviton DOS05-1LZ Decora Instruksi Manual

1. Bubuka

The Leviton DOS05-1LZ Decora Motion Sensor Light Switch is designed to provide automatic lighting control based on occupancy and motion detection. This 180° Passive Infrared (PIR) sensor can operate in either single-pole or 3-way configurations and does not require a neutral wire for installation, making it suitable for a wide range of residential applications. It is compatible with various load types including LED, CFL, Incandescent, Halogen, Magnetic Low Voltage, Éléktronik Low Voltage, and motor loads up to ¼ HP. This device helps enhance convenience and energy efficiency by automatically turning lights on when motion is detected and off after a set period of inactivity.

The switch includes interchangeable faceplates in White, Ivory, and Light Almond to match your decor. It can also be used to comply with 2019 California Title 24, Part 6 Vacancy Control Device Requirements.

2. Émbaran Kasalametan

WARNING: To avoid fire, shock, or death, always turn off power at the circuit breaker or fuse and test to ensure power is off before wiring. If you are unsure about any part of these instructions or are not comfortable or familiar with electrical wiring, contact a licensed electrician.

  • Alat ieu dirancang kanggo dianggo sareng kawat tambaga atanapi kawat anu dilapis tambaga hungkul.
  • Do not mount near a heat source or in drafty areas of the home, as temperature changes can affect sensor performance.
  • Avoid mounting in motion-heavy areas where unintended motion will be within the sensor's field of view, unless adjusted for specific coverage.

3. Eusi Paket

  • One Leviton DOS05-1LZ Motion Sensor Light Switch
  • Interchangeable faceplates (White, Ivory, Light Almond)
  • parentah instalasi

4. Pamasangan

4.1. Pakakas Diperlukeun

  • Obeng flathead
  • Obeng sirah Phillips
  • Electrician's pliers
  • Kawat lempeng
  • Pita listrik
  • Handheld voltage panguji
  • Properly sized wire connectors

4.2. Léngkah-léngkah Pra-Pamasangan

  1. Pareuman kakuatan dina circuit breaker atanapi sekering.
  2. Remove the existing switch plate and unscrew the old device from the wall box.
  3. Carefully pull the device out until you clearly see the wires.
  4. Paké voltage tester to ensure no power is present in the box.
  5. Carefully disconnect all wiring from the old device and remove it.
  6. Straighten and separate each wire. Ensure no exposed metal ends are touching.

4.3. Ngakabelkeun Saklar Sensor Gerak

The DOS05-1LZ can be wired with or without a neutral wire. Identify the wires in your wall box to determine the appropriate wiring configuration.

Leviton DOS05-1LZ Motion Sensor Switch with Wires

Figure 1: Leviton DOS05-1LZ Motion Sensor Switch with pre-stripped wires.

Balik deui view of Leviton DOS05-1LZ Motion Sensor Switch with wiring labels

Gambar 2: Balik view of the switch showing wiring terminals and labels.

4.3.1. Wiring without a Neutral Wire (Ground Connection)

  • Twist the green and yellow ground lead wire from the device and the green sleeve ground wire (if present) to the ground wire in the wall box. Secure with a properly sized wire connector and electrical tape.
  • Connect the black lead wires from the device to the black wires (line and load) in the wall box. The line and load wires can be wired interchangeably. Secure with wire connectors and electrical tape.
  • For DOS05-1LZ, cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

4.3.2. Wiring with a Neutral Wire

  • Remove the green sleeve from the white wire on the product. Connect this white wire to the white neutral wire(s) in the wall box. Secure with a properly sized wire connector and electrical tape.
  • Connect the green and yellow ground lead wire from the device to the ground wire in the wall box. Secure with a properly sized wire connector and electrical tape.
  • Connect the black lead wires from the device to the black wires (line and load) in the wall box. The line and load wires can be wired interchangeably. Secure with wire connectors and electrical tape.
  • For DOS05-1LZ, cap off the red/yellow wire with a wire connector as it is only used for 3-way connections.

Video 1: Detailed installation guide for Leviton Decora Occupancy and Vacancy Motion Sensor Light Switches (DOS05-1LZ included).

4.4. Léngkah ahir

  1. Gently bend the wires and push them into the wall box.
  2. Screw the sensor into the wall box.
  3. Install the wall plate (sold separately).
  4. Malikkeun listrik dina pemutus sirkuit atanapi sekering.

5. Parentah Operasi

5.1. Operasi dasar

  • Otomatis Hurung/Pareum: After a warm-up period (10-20 seconds), the lights will automatically turn on with the first motion detected. They will turn off after a set period of inactivity.
  • Manual Hurungkeun/Pareuman: Press the lower part of the push pad to manually turn the lights on or off.
  • Motion Detected Indicator: The red indicator light will flash anytime motion is detected.
  • Light Off Indicator: The green indicator light illuminates when the light (load) it controls is off.

5.2. Setélan Programmable

The DOS05-1LZ offers three programmable settings: Timer, Sensitivity, and Ambient Light. These settings can be adjusted directly from the push pad without tools or removing the faceplate.

Leviton Motion Sensor Switch with hands indicating no tools needed for settings

Figure 3: Adjust settings by pressing the push pad, no tools required.

5.2.1. Ngasupkeun Mode Programming

  1. Manually turn the light ON by pressing the push pad. The green LED will be off.
  2. Press the TOP and BOTTOM of the push pad simultaneously for 5 seconds.
  3. The green LED will turn on for 5 seconds, then the red LED will blink once, and the green LED will blink three times. This indicates you are in Programming Mode, currently in the Timer Setting (Option 3, 10 minutes, default).

Catetan: Programming Mode will time out after 30 seconds if no activity is detected, and changes will not be saved.

5.2.2. Changing Settings and Options

  • To change the Setting (Timer, Sensitivity, Ambient Light): Press the TOP of the push pad. The red LED will blink to indicate the setting number (1 blink for Timer, 2 for Sensitivity, 3 for Ambient Light).
  • To change the Setting Option (e.g., 1 minute, 5 minutes for Timer): Press the BOTTOM of the push pad. The green LED will blink to indicate the option number (1 blink for Option 1, 2 for Option 2, etc.).

5.2.3. Timer Setting (Setting 1)

Adjusts the duration the light remains ON after motion was last detected.

  • Option 1: 1 Minute
  • Option 2: 5 Minutes
  • Option 3: 10 Minutes (Default)
  • Option 4: 20 Minutes

5.2.4. Sensitivity Setting (Setting 2)

Adjusts the device's sensitivity to motion, affecting the detection range.

  • Option 1: Low (50% range)
  • Option 2: Medium (Default)
  • Option 3: High (Maximum coverage area)
Diagram showing 180 degree PIR detection range up to 900 sq ft

Figure 4: 180° PIR detection range, up to 900 sq. ft. Customize sensing range/coverage area for your application.

5.2.5. Ambient Light Setting (Setting 3 - Occupancy Sensors Only)

Adjusts the device's sensitivity to natural light, preventing lights from turning on if there is ample natural light in the room.

  • Option 1: Low Light Level
  • Option 2: Medium Light Level (Default)
  • Option 3: High/Brightest Light Level
  • Option 4: Disabled (Light turns on for all light levels regardless of ambient light)

5.3. Temporary Modes

5.3.1. Modeu Tés

Turns on the light for 5 seconds every time motion is detected. Useful for testing field of view coverage after installation.

  • Pikeun Aktipkeun: Press and hold the TOP of the push pad for 5 seconds. The red light will blink once every 2 seconds.
  • Pikeun Kaluar: Press the TOP or BOTTOM of the push pad, or it will automatically time out after 2 minutes.

5.3.2. Temporary Bypass Mode (Occupancy Sensors Only)

Ignores motion, preventing detection and keeping the light or load off. Useful when you want a room to remain dark even if there is motion (e.g., watching a movie).

  • Pikeun Aktipkeun: Press and hold the BOTTOM of the push pad for 5 seconds. The green light will double flash every 2 seconds.
  • Pikeun Kaluar: Press the TOP or BOTTOM of the push pad.

Video 2: How to Program the Leviton Decora Occupancy and Vacancy Motion Sensor Light Switches.

6. Cara ngungkulan

MasalahMungkin Cukang lantaranana / Solusi
Lights do not operate with push pad and RED indicator does not blink when motion is present.Verify wiring connections to sensor.
Lights do not switch ON when motion is detected (DOS05).
  • Motion is beyond sensing range - move closer to switch.
  • Saluyukeun tingkat lampu handap (Pilihan 3, 2, 1 atawa nonaktipkeun).
  • The RED light will blink to indicate motion. If it is blinking and the load is not turning ON, it could be due to ambient light OR check to make sure that the OCC switch is in OCC position.
Lights always stay ON.
  • Pariksa setélan waktos reureuh sareng bandingkeun sareng sabaraha lami lampu tetep ON.
  • Make sure no motion occurs in coverage area for time selected by covering the lens.
  • Check that switch is not installed near a heat source (like stove, lights, heat vents) or detecting motion from an adjacent area (like hallway traffic) and if it is, relocate it.
Lights do not turn ON (DVS05).
  • Pastikeun yén kontrol dipasang leres.
  • Pastikeun kakuatan keur ON.
  • Pariksa pikeun mastikeun bohlam lampu fungsina.

7. Spésifikasi

  • Jumlah modél: DOS05-1LZ
  • Modeu operasi: ON-OFF-ON
  • Peunteun ayeuna: 2 Amps
  • Operasi Voltage: 120 volt
  • Jenis Kontak: Biasana Buka
  • Tipe Panyambung: Crimp
  • Terminal: Sabeulah
  • Ukuran barang (L x W x H): 1.38 x 1.73 x 4.13 inci
  • Jenis sirkuit: 3-jalan
  • Tipe Aktuator: Pencét Tombol
  • Bahan Hubungan: Perunggu Fosfor
  • Peunteun Perlindungan Internasional: IP54
  • Jumlah Jabatan: 1
  • Peunteun Suhu Handap: 70 darajat Fahrenheit
  • Peunteun Suhu luhur: 100 darajat Fahrenheit
  • Jenis Controller: Pencét Tombol
  • Métode kontrol: Toél
  • Protokol konektipitas: X-10
  • warna: White/Ivory/Light Almond
  • Wattage: 600 watt
  • Alat anu cocog: LED, CFL, Incandescent, Halogen, Magnetic Low Voltage, Éléktronik Low Voltage, Motor loads
  • Sumber Daya: Kabel Listrik
  • Beurat barang: 4.6 ons

8. Pangropéa

To maintain optimal performance and appearance of your Leviton Motion Sensor Light Switch, follow these simple guidelines:

  • beberesih: Ngagunakeun lemes, damp cloth to clean the surface of the switch. Avoid abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish or internal components.
  • Pamariksaan: Mariksa périodik saklar pikeun tanda-tanda karusakan, sambungan leupas, atanapi operasi anu teu biasa. Upami aya masalah anu dititénan, pareumkeun listrik dina pemutus sirkuit sareng konsultasi ka tukang listrik anu mumpuni.
  • Perawatan lensa: Keep the sensor lens clean and free from dust or obstructions to ensure accurate motion detection.
  • Pertimbangan Lingkungan: Ensure the switch is not exposed to excessive moisture or extreme temperatures beyond its operating range, as this can affect its lifespan and functionality.

9. Garansi jeung Rojongan

This Leviton Motion Sensor Light Switch (DOS05-1LZ) comes with a 5-Taun jaminan kawates. For warranty claims, technical support, or further assistance, please contact Leviton customer service or visit their official websitus. Simpen bukti pameseran anjeun pikeun validasi jaminan.

Ask a question about this manual