1. Bubuka
The PeakTech 4095 is a newly developed, high-precision digital bench multimeter designed for professional use. It features a graphical TFT display for high-resolution visualization of measured values, trend curves, function graphs, and more. Capable of up to 150 measurements per second, this device incorporates advanced technical standards and a wide array of special functions, making it an indispensable tool for accurate electrical measurements and data analysis.
This manual provides comprehensive instructions for the safe and efficient operation, setup, maintenance, and troubleshooting of your PeakTech 4095 Digital Bench Multimeter. Please read it thoroughly before using the device.
2. Eusi Paket
Punten parios eusi bungkusan anjeun pikeun mastikeun yén sadaya barang aya sareng henteu ruksak:
- PeakTech 4095 Digital Bench Multimeter
- Kabel Daya
- Interface Cable (USB/RS-232)
- CD-ROM (with software and manual)
- Test Leads
- Sénsor Suhu
- User Manual (on CD-ROM)
Lamun aya item nu leungit atawa ruksak, mangga ngahubungan supplier Anjeun langsung.
3. Émbaran Kasalametan
Always adhere to the following safety precautions to prevent personal injury or damage to the device:
- This device complies with safety standards EN 61010-1; CAT I 1000V / CAT II 600 V.
- Do not exceed the maximum input values for any measurement range.
- Ensure the device is properly grounded before operation.
- Do not operate the device if it appears damaged or if the insulation is compromised.
- Use only the specified test leads and accessories.
- Hindarkeun kontak sareng sirkuit langsung.
- Ulah make alat dina baseuh atawa damp lingkungan.
- Pegatkeun sambungan kakuatan saméméh meresihan atawa ngalayanan alat.
4. Fitur Produk
The PeakTech 4095 offers a comprehensive set of features for precise and versatile measurements:
- Graphical TFT Display: 4 1/2 digit (60,000 counts) 4-inch display (480x320 pixels) for high-resolution data visualization.
- High Measurement Speed: Up to 150 measured values per second.
- Pangukuran True RMS: Accurate True RMS measurements up to 100 kHz, depending on the measurement function.
- Logger Data: Internal memory for up to 1 million points or external logging to a USB stick for up to 100 million points, with a 5 ms interval.
- Dual Measurement Function: Simultaneously measure two different functions.
- Advanced Display Modes: Histogram, Barometer, Trend display, Pass/Fail function.
- Fungsi pangukuran: DCV, ACV, DCA, ACA, Resistance, Frequency, Capacitance, Diode Test, Continuity Test, Temperature.
- Pangukuran Suhu: Supports 2- or 3-wire resistance/thermocouple measurements via types B/E/J/K/N/R/S/T or PT100/PT385.
- Konektipitas: RS-232, LAN network connection, and USB interfaces for PC control and data retrieval via SCPI protocol.
- Pilihan Range: Pilihan rentang otomatis sareng manual.
- Fungsi tambahan: AVG, MIN/MAX, and relative value measurement.
Gambar 1: Hareupeun view of the PeakTech 4095 Digital Bench Multimeter.
Figure 2: Close-up of the PeakTech 4095 front panel showing the graphical TFT display in trend mode.
Figure 3: Rear panel of the PeakTech 4095, displaying the power input, LAN, USB, RS-232, and auxiliary ports.
Figure 4: The PeakTech 4095 Digital Bench Multimeter in a typical laboratory or workshop environment, connected for measurement.
5. Setélan
Follow these steps to set up your PeakTech 4095 Multimeter:
- Ngabongkar bungkusan: Carefully remove the multimeter and all accessories from the packaging. Retain the packaging for future storage or transport.
- Sambungan Daya: Locate the power input on the rear panel. Ensure the voltage selector switch (110V/240V) matches your local power supply. Connect the provided power cable to the multimeter and then to a suitable AC outlet.
- Daya mimiti Hurung: Press the power button on the front panel. The TFT display should illuminate, and the device will perform a self-test.
- Nyambungkeun Kabel Tés: Insert the red test lead into the 'HI' input terminal and the black test lead into the 'LO' input terminal for most voltage, resistance, and frequency measurements. For current measurements, refer to the specific input terminals (e.g., 10A, mA/µA).
- Interface Connection (Optional):
- USB: Connect the USB cable from the multimeter's rear USB port to your computer.
- RS-232: Connect the RS-232 cable from the multimeter's rear RS-232 port to your computer's serial port (or a USB-to-serial adapter).
- LAN: Connect an Ethernet cable from the multimeter's LAN port to your network router or switch.
Install the provided software from the CD-ROM on your computer to enable remote control and data logging via these interfaces.
6. Parentah Operasi
This section outlines the basic operation and various measurement functions of the PeakTech 4095.
6.1 Pangukuran Dasar
- Voltage (DCV/ACV): Pilih vol anu dipikahoyongtage function (DCV or ACV) using the function buttons. Connect the test leads in parallel to the circuit under test. The display will show the measured voltage.
- Current (DCA/ACA): Select the desired current function (DCA or ACA). Ensure the test leads are connected to the appropriate current input terminals (e.g., 10A, mA/µA). Connect the multimeter in series with the circuit.
- Resistance (Ohm): Select the Ohm function. Connect the test leads across the component to measure its resistance. Ensure the circuit is de-energized before measuring resistance.
- Kapasitansi: Select the Capacitance function. Connect the test leads across the capacitor. Ensure the capacitor is discharged before measurement.
- Frékuénsi: Select the Frequency function. Connect the test leads to the signal source.
- Suhu: Connect the provided temperature sensor or a compatible thermocouple/RTD to the appropriate input terminals. Select the Temperature function and choose the correct sensor type (e.g., Type K, PT100).
6.2 Fungsi Husus
- Pilihan Range: Use the 'Range' button to switch between auto-ranging and manual ranging. In manual mode, press 'Range' repeatedly to cycle through available ranges.
- MIN/MAX/RATA-RATA: Press the 'Math' button and navigate to MIN/MAX/AVG to display the minimum, maximum, or average values recorded during a measurement session.
- Pangukuran Relatif: Use the 'Math' button to activate the relative measurement function, which displays the difference between the current reading and a stored reference value.
- Data logging: Press the 'Record' button to start/stop data logging. Configure logging parameters (interval, internal/external memory) via the 'Record' menu. Data can be saved to internal memory or an external USB stick.
- Graphical Display Modes: Use the 'Graph' and 'Dual' buttons to switch between numerical display, trend graphs, histograms, and dual measurement displays.
7. Pangropéa
Proper maintenance ensures the longevity and accuracy of your PeakTech 4095 Multimeter.
7.1 beberesih
Rutin ngabersihkeun luar alat ku hipu, damp lawon. Ulah nganggo pembersih atanapi pangleyur anu abrasif. Pastikeun teu aya Uap anu asup kana alat.
7.2 Ngagantian sekering
If the current measurement function fails, the fuse may need replacement. Refer to the specifications for the correct fuse type and rating. Disconnect the power cable and all test leads before attempting to replace the fuse. Fuse access is typically on the rear panel or under a designated cover.
7.3 Kalibrasi
For continued accuracy, periodic calibration by a qualified service center is recommended. Refer to the PeakTech website or contact customer support for calibration services.
8. Cara ngungkulan
If you encounter issues with your PeakTech 4095, refer to the following common problems and solutions:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Alat teu hurung. | No power supply; power cable loose; incorrect voltage selector; blown fuse. | Check power cable connection; verify voltage selector setting; check and replace power fuse if necessary. |
| Incorrect or no readings. | Incorrect function selected; test leads not properly connected; circuit issue; out of range. | Select correct measurement function; ensure test leads are securely connected; verify circuit integrity; switch to auto-ranging or a higher manual range. |
| Pangukuran arus teu jalan. | Blown current fuse; incorrect input terminal. | Check and replace the internal current fuse; ensure test leads are connected to the correct current input (e.g., 10A, mA/µA). |
| PC software cannot connect. | Incorrect interface cable; driver not installed; wrong COM port selected; firewall blocking connection. | Ensure correct USB/RS-232/LAN cable is used; install drivers from CD-ROM; verify COM port settings in software; check firewall settings. |
If the problem persists after attempting these solutions, please contact PeakTech customer support.
9. Spésifikasi
Detailed technical specifications for the PeakTech 4095 Digital Bench Multimeter:
| Parameter | Spésifikasi |
|---|---|
| tampilan | 4 1/2 digits (60,000 counts) TFT graphical display, 4" (480x320 pixels) |
| Laju pangukuran | Up to 150 values/second |
| DC Voltage (DCV) | 600mV / 6/60/600/1000 V; ± 0.02% + 0.01 |
| AC Voltage (ACV) | 600 mV / 6/60/600/750 V; ± 0.2% + 0.06 (TRMS Frequency: 20 Hz - 100 kHz) |
| Arus DC (DCA) | 600µA / 6/60/600 mA / 6/10 A; ± 0.06% + 0.02 |
| Arus AC (ACA) | 60 / 600mA / 6/10 A; ± 0.5% + 0.10 (TRMS Frequency: 20 Hz - 10 kHz) |
| Résistansi (Ohm) | 600 Ω / 6/60/600 kΩ / 6/60/100 MΩ; ± 0.03% + 0.01 |
| Frékuénsi | 20 Hz… 1 MHz ± 0.01% + 0.003 |
| Kapasitansi | 2/20/200 nF / 2/200 / 10000 µF; ± 1% + 0.5 |
| Temperature (RTD) | -200 °C… +660 °C; ± 0.08% + 0.002 |
| Suhu (Tipe K) | -200 °C… +1372 °C; ± 0.5 °C |
| Data Logger Memory | Internal: 1 million points; External (USB): 100 million points |
| Operasi Voltage | 110 V / 240 V; 50/60 Hz (switchable) |
| Ukuran (L x W x H) | 235 x 110 x 295 mm |
| Beurat | 3 kg |
| Peunteun Kasalametan | EN 61010-1; CAT I 1000V / CAT II 600 V |
| Negara asal | Cina |
10. Garansi jeung Rojongan
PeakTech products are manufactured with high quality standards and are subject to strict quality control. This device is covered by a standard manufacturer's warranty against defects in materials and workmanship.
For warranty claims, technical support, or service inquiries, please contact PeakTech customer service or your local distributor. Please have your model number (P 4095) and purchase information ready when contacting support.
For the most up-to-date information, drivers, and software, please visit the official PeakTech websitus.