Bubuka
This manual provides detailed instructions for the installation, operation, and maintenance of your Jebao DCP-4000 Sine Wave Water Return Pump. The DCP series pumps offer enhanced performance and precise flow control, making them suitable for various aquarium applications including reactors, sumps, and closed-loop systems. Please read this manual thoroughly before use to ensure proper function and longevity of the product.

Image 1: Jebao DCP-4000 pump and its retail packaging.
Fitur produk
- High-performance motor with innovative electronics, offering energy savings up to 50% compared to older models.
- No copper components, ensuring safety for aquatic environments. Designed for internal use only.
- Super quiet operation for minimal disturbance.
- Memory function to recall settings after power supply interruption.
- Integrated motor protection system activates if the rotor is blocked.
- Complete flow control via the DCP Controller.
- Feed mode function (10 minutes duration).
Parentah Kasalametan
Mangga perhatoskeun tindakan pencegahan kaamanan ieu pikeun nyegah cilaka atanapi karusakan kana produk.
- Salawasna pegatkeun sambungan kakuatan saméméh ngajalankeun sagala pangropéa atawa instalasi.
- Ensure the pump is fully submerged in water during operation to prevent overheating.
- Entong jalankeun pompa upami kabel listrik atanapi colokan rusak.
- This pump is designed for internal use in aquatic environments only. Do not use for other purposes.
- Keep the controller and power adapter dry and away from water.
- Regularly inspect the pump and connections for any signs of wear or damage.
- Pastikeun sadaya sambungan aman pikeun nyegah bocor.
Eusi pakét
Pastikeun yén sadaya komponén aya dina bungkusan:
- Jebao DCP Pump (DCP-4000)
- Adaptor AC
- DCP Controller
- Various connection fittings and O-rings

Image 2: All included components: pump, controller, power adapter, and various fittings.
Parentah Setup
- Nyiapkeun Pompa:
The pump comes with an intake screen and threaded output. Attach the appropriate fittings for your plumbing system. The DCP-4000 is compatible with 3/4" PVC for hard piping or 3/4" barb fittings for flexible tubing. Ensure O-rings are properly seated for a watertight seal.

Gambar 3: Hareupeun view of the pump showing the intake screen.
- Pasang Pompa:
Place the pump in your sump or desired location, ensuring it is fully submerged. The pump base provides stability.
- Sambungkeun Pipa:
Connect your return plumbing to the pump's output. Use hose clamps for barb fittings to ensure a secure connection and prevent leaks. For PVC connections, use appropriate PVC glue and primer.

Image 4: Pump with the output fitting detached, showing the threaded connection.
- Connect Controller and Power:
Connect the pump cable to the DCP controller. Then, connect the AC adapter to the controller and plug the adapter into a grounded electrical outlet. Ensure all connections are dry before plugging into power.

Image 5: The pump connected to its digital controller.
Parentah Operasi
The DCP controller allows for precise adjustment of the pump's flow rate and includes a feed mode.
- Hurungkeun/Pareuman:
Plug in the AC adapter. The pump will start at its last saved setting due to the memory function.
- Saluyukeun Laju Aliran:
Use the "+" and "-" buttons on the controller to increase or decrease the pump's output. The digital display will show the current power level or flow setting.
- Modeu eupan:
Press the "Feed" button (often labeled with a fish icon or "F") to activate feed mode. The pump will temporarily shut off for 10 minutes, allowing fish to feed without being disturbed by water flow. After 10 minutes, the pump will automatically resume its previous operation.
Pangropéa
Pangropéa rutin mastikeun kinerja anu optimal sareng manjangkeun umur pompa anjeun.
- Pegatkeun Daya:
Salawasna cabut pompa tina stop kontak sateuacan ngalaksanakeun pangropéa naon waé.
- Clean the Impeller and Housing:
Remove the intake screen and front housing. Carefully remove the impeller assembly. Clean any debris, algae, or calcium buildup from the impeller, impeller shaft, and pump housing using a soft brush and vinegar or a mild acid solution designed for aquarium equipment. Rinse thoroughly with fresh water.

Image 6: Pump with the intake screen detached, showing the impeller area.
- Pariksa O-Cingcin:
Check all O-rings for cracks, wear, or compression. Replace any damaged O-rings to prevent leaks. Apply a thin layer of silicone grease (aquarium safe) to O-rings before reassembly to ensure a good seal and ease of future disassembly.
- Pasang deui:
Carefully reassemble the pump, ensuring all parts are correctly seated and secured. Reconnect plumbing and power.
Pamérésan masalah
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pump does not start or runs intermittently. |
|
|
| Laju aliran anu dikirangan. |
|
|
| Noise atawa geter kaleuleuwihan. |
|
|
| Cai bocor. |
|
|
Specifications (DCP-4000)
| Fitur | Rincian |
|---|---|
| Modél | DCP-4000 |
| Kakuatan | 32 Watt |
| Voltage | 110-120V, 60Hz |
| Laju aliran maksimum | 1056 GPH (4000 L/H) / 17.6 Gallons Per Minute |
| Jangkungna Kepala maksimum | 13 Suku (4.0 M) |
| Dimensi produk | 7.1"L x 3.1"W x 7.1"H (Pump body: 6x3x4 inches) |
| Item Beurat | 4.1 pon |
| Bahan | Copper-free construction |
| UPC | 651046608004 |

Image 7: Diagram showing the dimensions of the Jebao DCP-4000 pump.
Garansi sareng Rojongan
Garansi: The Jebao DCP-4000 Sine Wave Water Return Pump comes with a 180-day warranty from the date of purchase. This warranty covers manufacturing defects under normal use. It does not cover damage resulting from misuse, improper installation, neglect, or unauthorized modifications.
Rojongan Palanggan: For technical assistance, troubleshooting, or warranty claims, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty services.