The Audio-Technica VM510CB is a dual moving magnet stereo turntable cartridge designed for accurate sound reproduction. It features a 0.6 mil conical bonded stylus, engineered to track the center of the record groove for reliable performance and high fidelity. This cartridge is part of Audio-Technica's VM cartridge line, incorporating advanced technology for optimal channel separation and extended frequency response. This manual provides essential information for the proper installation, operation, and maintenance of your VM510CB cartridge.
Fitur konci
- Dual Magnet Design: Matches left and right channels in the stereo record groove for superior channel separation and extended frequency response.
- Conical Bonded Stylus: A 0.6 mil conical bonded stylus ensures reliable tracking and excellent fidelity.
- Paratoroidal Coils: Engineered to improve generating efficiency.
- Center Shield Plate: Reduces crosstalk between the left and right channels.
- Perumahan awét: Constructed with low-resonance polymer for enhanced sound quality.
- Aluminum Cantilever: Provides robust support for the stylus.
- Hardware dipasang: Includes necessary hardware for installation.
Setup sareng Instalasi
Proper installation of the VM510CB cartridge is crucial for optimal performance. Please follow these steps carefully. If you are unsure about any step, consult a qualified audio technician or your turntable's instruction manual.
1. Unpacking jeung Inspection
Carefully remove the cartridge from its packaging. Inspect the stylus for any visible damage. Avoid touching the stylus tip directly.

Image: The VM510CB cartridge viewed from a top-front angle, showing the blue body and gold pins.
2. Pasang Kartrid
- Pastikeun turntable anjeun dipareuman sareng dicabut.
- If replacing an existing cartridge, carefully remove it from the headshell. Note the wiring connections.
- Attach the VM510CB cartridge to your turntable's headshell using the supplied mounting hardware (screws and nuts). Do not overtighten the screws initially, as you may need to adjust the cartridge position for alignment.
- Connect the headshell wires to the corresponding pins on the cartridge. The standard color code is:
- White (L+): Left channel hot
- Blue (L-): Saluran kénca taneuh
- Red (R+): Right channel hot
- Green (R-): Saluran katuhu taneuh

Image: The VM510CB cartridge viewed from a side-front angle, showing the blue body, clear stylus guard, and gold connection pins.
3. Pangaturan Kartrid
Accurate alignment is critical for optimal sound quality and to prevent record wear. This typically involves setting overhang, azimuth, and vertical tracking angle (VTA).
- Overhang: Use an alignment protractor (often supplied with your turntable or available separately) to position the cartridge correctly in the headshell. Adjust the cartridge forward or backward until the stylus tip aligns with the designated points on the protractor.
- Azimuth: Ensure the cartridge body is parallel to the record surface when viewed from the front. Some headshells allow for azimuth adjustment.
- Vertical Tracking Angle (VTA): The tonearm should be parallel to the record surface when the stylus is resting in a groove. Adjust the tonearm height if your turntable allows.
- Once aligned, carefully tighten the mounting screws.
4. Nyetél Gaya Pelacak
The recommended tracking force for the VM510CB is typically between 1.8 to 2.2 grams. Refer to your turntable's manual for instructions on how to set the tracking force using the tonearm counterweight. An accurate stylus force gauge is recommended for precise adjustment.
5. Setting Anti-Skate
Set the anti-skate (or bias) control on your turntable to match the tracking force. This helps prevent the stylus from being pulled towards the center of the record.
Operasi
Once installed and properly adjusted, operating the VM510CB cartridge involves standard turntable usage procedures.
- Pastikeun turntable anjeun disambungkeun ka phono preampLifier atanapi an amplifier kalawan input phono dedicated.
- Place a record on the platter and ensure it is clean.
- Carefully lower the tonearm onto the record's lead-in groove using the tonearm lift mechanism. Avoid dropping the tonearm directly onto the record.
- At the end of the record, use the tonearm lift to raise the tonearm and return it to its rest.
- Always engage the stylus guard when the turntable is not in use or when moving the turntable to protect the stylus.

Gambar: A lengkep view of the VM510CB cartridge, highlighting the conical stylus tip with a magnified inset.
Pangropéa
Regular maintenance ensures the longevity and optimal performance of your VM510CB cartridge.
- Stylus beberesih: Clean the stylus regularly using a soft stylus brush, brushing gently from back to front (in the direction of play). Never brush from side to side or front to back, as this can damage the stylus. Specialized stylus cleaning fluids can also be used sparingly.
- beberesih rékaman: Always play clean records. Dust and debris on records can accumulate on the stylus, degrading sound quality and potentially damaging both the stylus and your records.
- Ngagantian Stylus: The stylus is a delicate component that wears down over time. The lifespan of a stylus varies depending on usage and record condition, but typically ranges from 500 to 1000 hours of play. A worn stylus can damage records and degrade sound quality. Replace the stylus with an Audio-Technica VMN10CB replacement stylus when wear is evident or after the recommended playing hours.
- Pembersihan Awak Kartrid: Use a soft, dry cloth to wipe the cartridge body if it becomes dusty. Avoid using harsh chemicals.

Gambar: A close-up view of the VM510CB cartridge's conical stylus tip, showing its precise shape.
Pamérésan masalah
If you encounter issues with your VM510CB cartridge, consider the following common problems and solutions:
- No Sound or Weak Sound:
- Check all connections from the cartridge to the headshell, tonearm, and amplifier. Ensure they are secure and correctly wired (L+/L-, R+/R-).
- Pariksa yén anjeun amplifier's input is set to "Phono" and that your phono preamplifier (if external) is powered on.
- Inspect the stylus for damage or excessive dirt.
- Sora Anu Distorsi atanapi Pelacakan Anu Goréng:
- Re-check the tracking force. It should be within the recommended range (1.8-2.2g).
- Verify cartridge alignment (overhang, azimuth, VTA).
- Clean the stylus. A dirty or worn stylus can cause distortion.
- Ensure records are clean and free of debris.
- Check anti-skate setting.
- Sora ngahiung atawa ngagaur:
- Pastikeun kabel ground turntable disambungkeun kalayan leres kana ampterminal taneuh lifier.
- Check for loose connections in the headshell wiring.
- Move the turntable away from other electronic devices that might cause interference.
- Ngaluncat:
- Increase tracking force slightly within the recommended range.
- Inspect the stylus for damage or excessive dirt.
- Ensure the record is flat and clean.
- Check anti-skate setting.
spésifikasi
| Fitur | Rincian |
|---|---|
| Nomer modél | VM510CB |
| Tipe Stylus | 0.6 mil Conical Bonded |
| Cartridge Tipe | Dual Moving Magnet |
| Disarankeun Tracking Force | 1.8 nepi ka 2.2 gram |
| Dimensi produk | 4 x 2 x 3 inci |
| Item Beurat | 1.76 ons (50 gram) |
| Bahan | Aluminum (Cantilever) |
| Komponén Kaasup | Cartridge, Mounting Hardware |
| Alat nu cocog | Turntables connected to Desktop, Headphone, Laptop, Personal Computer, Speaker systems (via appropriate pre-amppangajén) |
Garansi sareng Rojongan
Kanggo inpormasi garansi sareng dukungan téknis, mangga tingal Audio-Technica resmi websitus atanapi ngahubungan departemén layanan palanggan maranéhna. Simpen resi pameseran anjeun salaku bukti pameseran.
Dukungan Online: Rojongan Audio-Technica