1. Bubuka
This manual provides comprehensive instructions for the setup, operation, and maintenance of your Jebao Jecod DP-2 Programmable Auto Dosing Pump. This device is designed to precisely dispense liquids into your aquarium, helping to maintain stable water parameters. Please read this manual thoroughly before use to ensure proper function and longevity of your unit.
2. Produk Langkungview
The Jebao Jecod DP-2 is a 2-channel programmable auto dosing pump. Each channel can be programmed to dispense a precise amount of solution up to 24 times per day, ranging from 1ml to 9999ml. This functionality is ideal for maintaining consistent levels of various supplements in your aquarium, such as calcium, magnesium, or alkalinity solutions.
Fitur konci:
- Two independent dosing channels.
- Programmable dosing volume from 1ml to 9999ml per day per channel.
- Up to 24 programmable dosing times per day per channel.
- Suitable for various liquid supplements in aquatic environments.
- Lega voltage compatibility: 110V to 240V, 50/60Hz.
Komponén produk:

Gambar 1: Hareupeun view of the Jebao Jecod DP-2 Dosing Pump, showing the two pump heads, control panel, and power indicators.

Gambar 2: Angled view of the Jebao Jecod DP-2 Dosing Pump, highlighting the peristaltic pump heads and tubing connections.

Gambar 3: The Jebao Jecod DP-2 Dosing Pump shown alongside its retail packaging.
3. Setélan
3.1 Ngabongkar bungkusan
Carefully remove the dosing pump and all accessories from the packaging. Inspect the unit for any signs of damage. Retain the packaging for future transport or storage.
3.2 Idéntifikasi komponén
- Dosing Pump Unit (DP-2)
- Adaptor Daya AC
- (Dosing tubing is not included and must be purchased separately.)
3.3 Panempatan Awal
Place the dosing pump on a stable, dry surface. Ensure it is positioned above the liquid reservoirs to prevent siphoning and below the aquarium water level if dosing directly into the tank. Avoid placing the unit in direct sunlight or areas with high humidity.
3.4 Sambungan Daya
- Connect the AC power adapter to the dosing pump's power input port.
- Plug the power adapter into a suitable electrical outlet (110V-240V, 50/60Hz).
- Unit bakal hurung, sareng layar bakal hurung.
3.5 Pamasangan Pipa
Dosing tubing is not supplied with the unit. Acquire appropriate aquarium-grade dosing tubing (e.g., silicone or PVC). Cut the tubing to the required lengths for your setup.
- Connect one end of the tubing to the inlet port of each pump head (P1 and P2). Ensure a secure fit.
- Place the other end of the inlet tubing into your liquid supplement reservoirs.
- Connect tubing to the outlet port of each pump head.
- Route the outlet tubing to your aquarium, securing it to prevent accidental displacement. Ensure the tubing ends are above the water level to prevent back-siphoning when the pump is off, or use check valves.
3.6 Kalibrasi
Accurate calibration is crucial for precise dosing. A 100ml graduated cylinder or measuring cup (not included) is required for this step.
- Fill a graduated cylinder with 100ml of the liquid you intend to dose.
- Place the inlet tubing into the liquid in the cylinder and the outlet tubing into a waste container.
- Access the calibration menu on the pump (refer to the "Operation" section for navigation).
- Initiate a calibration cycle for the desired pump (P1 or P2). The pump will run for a set period.
- Measure the actual volume dispensed. Adjust the calibration setting on the pump until the dispensed volume matches the target (e.g., 100ml).
- Repeat for the second pump head.
4. Operasi
4.1 Control Panel Leuwihview
The control panel features an LCD display and several buttons for navigation and programming. Familiarize yourself with the button functions:
- Panah luhur/handap: Napigasi ngaliwatan pilihan menu tur saluyukeun nilai.
- Panah Kénca/Katuhu: Move cursor or select different parameters.
- Enter/Set Button: Confirm selections or enter programming mode.
- Tombol ESC: Exit current menu or cancel an action.
4.2 Programming Dosing Schedules
The DP-2 allows for highly customizable dosing schedules for each pump.
- Tina layar utama, pencét éta Lebetkeun tombol pikeun ngakses ménu utama.
- Navigate to the "Program" or "Setting" option using the Luhur/Turun arrows and press Lebetkeun.
- Select the pump you wish to program (P1 or P2).
- Set the current time and date if prompted.
- For each dosing event (up to 24 per day):
- Set the desired time for the dose.
- Set the volume to be dispensed (1ml to 9999ml).
- Set the frequency (e.g., daily, every other day). Note: Some models may interpret '0' as daily and '1' as every other day. Consult the on-screen prompts.
- Save your settings before exiting the programming menu.
- Repeat the process for the second pump if needed.
Catetan: It is recommended to start with small dosing volumes and gradually increase as needed, monitoring your aquarium parameters closely.
4.3 Dosing Manual
The pump may offer a manual dosing function for testing or immediate dispensing. Refer to the on-screen menu for this option, typically found under a "Manual" or "Test" setting.
5. Pangropéa
5.1 Ngabersihan Rutin
Regular cleaning helps ensure optimal performance and extends the life of your dosing pump.
- Usap bagian luar unit nganggo iklanamp lawon. Hindarkeun ngagunakeun bahan kimia anu kasar.
- Periodically check tubing for blockages, kinks, or algae buildup.
- If dosing solutions are prone to crystallization, flush the tubing with distilled water regularly.
5.2 Pump Head Inspection
Inspect the peristaltic pump heads for wear and tear. The rollers and tubing inside the pump head are consumable parts and will require replacement over time.
5.3 Panggantian Pipa
Dosing tubing can harden or become brittle over time, affecting dosing accuracy. Replace tubing as needed, typically every 6-12 months depending on usage and solution type.
6. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pump not dispensing liquid. |
|
|
| Inaccurate dosing volume. |
|
|
| Pump making unusual noise. |
|
|
7. Spésifikasi
| Fitur | Rincian |
|---|---|
| Modél | DP-2 |
| merek | Jebao |
| Saluran | 2 |
| Dosing Volume per Channel | 1 - 9999 ml/day |
| Dosing Frequency per Channel | Up to 24 times/day |
| Input kakuatan | AC 110V - 240V, 50/60Hz |
| Bahan | Plastik, Polipropilén (PP) |
| Warna | Hideung |
| Ukuran produk (L x W x H) | 10" x 6" x 3" (25.4 cm x 15.24 cm x 7.62 cm) |
| Item Beurat | 1.83 Pon (0.83 kg) |
| Laju aliran maksimum | 6.9 Milliliters Per Minute |
| Mangpaat husus | Indoor aquarium dosing |
8. Garansi jeung Rojongan
8.1 Émbaran jaminan
This Jebao Jecod DP-2 Dosing Pump comes with a garansi 180 poé from the date of purchase. This warranty covers manufacturing defects under normal use. It does not cover damage resulting from misuse, accident, modification, or unauthorized repair. Please retain your proof of purchase for warranty claims.
8.2 Rojongan Palanggan
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your retailer or the manufacturer's customer service department. Contact information can typically be found on the product packaging or the manufacturer's official websitus.