Jebao DP-2

Jebao Jecod DP-2 Programmable Auto Dosing Pump User Manual

Modél: DP-2

1. Bubuka

This manual provides comprehensive instructions for the setup, operation, and maintenance of your Jebao Jecod DP-2 Programmable Auto Dosing Pump. This device is designed to precisely dispense liquids into your aquarium, helping to maintain stable water parameters. Please read this manual thoroughly before use to ensure proper function and longevity of your unit.

2. Produk Langkungview

The Jebao Jecod DP-2 is a 2-channel programmable auto dosing pump. Each channel can be programmed to dispense a precise amount of solution up to 24 times per day, ranging from 1ml to 9999ml. This functionality is ideal for maintaining consistent levels of various supplements in your aquarium, such as calcium, magnesium, or alkalinity solutions.

Fitur konci:

Komponén produk:

Jebao Jecod DP-2 Dosing Pump front view

Gambar 1: Hareupeun view of the Jebao Jecod DP-2 Dosing Pump, showing the two pump heads, control panel, and power indicators.

Jebao Jecod DP-2 Dosing Pump angled view

Gambar 2: Angled view of the Jebao Jecod DP-2 Dosing Pump, highlighting the peristaltic pump heads and tubing connections.

Jebao Jecod DP-2 Dosing Pump with packaging

Gambar 3: The Jebao Jecod DP-2 Dosing Pump shown alongside its retail packaging.

3. Setélan

3.1 Ngabongkar bungkusan

Carefully remove the dosing pump and all accessories from the packaging. Inspect the unit for any signs of damage. Retain the packaging for future transport or storage.

3.2 Idéntifikasi komponén

3.3 Panempatan Awal

Place the dosing pump on a stable, dry surface. Ensure it is positioned above the liquid reservoirs to prevent siphoning and below the aquarium water level if dosing directly into the tank. Avoid placing the unit in direct sunlight or areas with high humidity.

3.4 Sambungan Daya

  1. Connect the AC power adapter to the dosing pump's power input port.
  2. Plug the power adapter into a suitable electrical outlet (110V-240V, 50/60Hz).
  3. Unit bakal hurung, sareng layar bakal hurung.

3.5 Pamasangan Pipa

Dosing tubing is not supplied with the unit. Acquire appropriate aquarium-grade dosing tubing (e.g., silicone or PVC). Cut the tubing to the required lengths for your setup.

  1. Connect one end of the tubing to the inlet port of each pump head (P1 and P2). Ensure a secure fit.
  2. Place the other end of the inlet tubing into your liquid supplement reservoirs.
  3. Connect tubing to the outlet port of each pump head.
  4. Route the outlet tubing to your aquarium, securing it to prevent accidental displacement. Ensure the tubing ends are above the water level to prevent back-siphoning when the pump is off, or use check valves.

3.6 Kalibrasi

Accurate calibration is crucial for precise dosing. A 100ml graduated cylinder or measuring cup (not included) is required for this step.

  1. Fill a graduated cylinder with 100ml of the liquid you intend to dose.
  2. Place the inlet tubing into the liquid in the cylinder and the outlet tubing into a waste container.
  3. Access the calibration menu on the pump (refer to the "Operation" section for navigation).
  4. Initiate a calibration cycle for the desired pump (P1 or P2). The pump will run for a set period.
  5. Measure the actual volume dispensed. Adjust the calibration setting on the pump until the dispensed volume matches the target (e.g., 100ml).
  6. Repeat for the second pump head.

4. Operasi

4.1 Control Panel Leuwihview

The control panel features an LCD display and several buttons for navigation and programming. Familiarize yourself with the button functions:

4.2 Programming Dosing Schedules

The DP-2 allows for highly customizable dosing schedules for each pump.

  1. Tina layar utama, pencét éta Lebetkeun tombol pikeun ngakses ménu utama.
  2. Navigate to the "Program" or "Setting" option using the Luhur/Turun arrows and press Lebetkeun.
  3. Select the pump you wish to program (P1 or P2).
  4. Set the current time and date if prompted.
  5. For each dosing event (up to 24 per day):
    • Set the desired time for the dose.
    • Set the volume to be dispensed (1ml to 9999ml).
    • Set the frequency (e.g., daily, every other day). Note: Some models may interpret '0' as daily and '1' as every other day. Consult the on-screen prompts.
  6. Save your settings before exiting the programming menu.
  7. Repeat the process for the second pump if needed.

Catetan: It is recommended to start with small dosing volumes and gradually increase as needed, monitoring your aquarium parameters closely.

4.3 Dosing Manual

The pump may offer a manual dosing function for testing or immediate dispensing. Refer to the on-screen menu for this option, typically found under a "Manual" or "Test" setting.

5. Pangropéa

5.1 Ngabersihan Rutin

Regular cleaning helps ensure optimal performance and extends the life of your dosing pump.

5.2 Pump Head Inspection

Inspect the peristaltic pump heads for wear and tear. The rollers and tubing inside the pump head are consumable parts and will require replacement over time.

5.3 Panggantian Pipa

Dosing tubing can harden or become brittle over time, affecting dosing accuracy. Replace tubing as needed, typically every 6-12 months depending on usage and solution type.

6. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Pump not dispensing liquid.
  • Taya kakuatan.
  • Tubing kinked or blocked.
  • Ngompa teu purun.
  • Pamrograman anu salah.
  • Pump head worn out.
  • Pariksa sambungan kakuatan.
  • Mariksa sareng ngabersihan pipa.
  • Manually run pump to prime.
  • Verify dosing schedule and volume settings.
  • Inspect and replace pump head if necessary.
Inaccurate dosing volume.
  • calibration teu bener.
  • Air bubbles in tubing.
  • Worn pump tubing.
  • Solution viscosity changed.
  • Recalibrate the pump.
  • Ensure tubing is submerged and free of air.
  • Replace pump tubing.
  • Recalibrate with the current solution.
Pump making unusual noise.
  • Worn pump head rollers.
  • Debris in pump head.
  • Inspect and replace pump head.
  • Clean pump head thoroughly.

7. Spésifikasi

FiturRincian
ModélDP-2
merekJebao
Saluran2
Dosing Volume per Channel1 - 9999 ml/day
Dosing Frequency per ChannelUp to 24 times/day
Input kakuatanAC 110V - 240V, 50/60Hz
BahanPlastik, Polipropilén (PP)
WarnaHideung
Ukuran produk (L x W x H)10" x 6" x 3" (25.4 cm x 15.24 cm x 7.62 cm)
Item Beurat1.83 Pon (0.83 kg)
Laju aliran maksimum6.9 Milliliters Per Minute
Mangpaat hususIndoor aquarium dosing

8. Garansi jeung Rojongan

8.1 Émbaran jaminan

This Jebao Jecod DP-2 Dosing Pump comes with a garansi 180 poé from the date of purchase. This warranty covers manufacturing defects under normal use. It does not cover damage resulting from misuse, accident, modification, or unauthorized repair. Please retain your proof of purchase for warranty claims.

8.2 Rojongan Palanggan

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact your retailer or the manufacturer's customer service department. Contact information can typically be found on the product packaging or the manufacturer's official websitus.

Dokumén Patali - DP-2

Praview Buku Panduan Pangguna Jebao Smart Wave Maker - Setelan, Operasi, sareng Pangungkulan Masalah
Buku panduan lengkep pikeun Jebao Smart Wave Maker (MCP, MLW, MOW SERIES), anu ngawengku pamasangan, fitur, kontrol aplikasi via Jebao Aqua, rupa-rupa modeu gelombang, ngungkulan masalah, sareng pangropéa. Diajar kumaha nyetél sareng ngoperasikeun Jebao wave maker anjeun pikeun kaayaan akuarium anu optimal.
Praview Jebao Jecod DMP Series Smart Wave Maker User Manual
Comprehensive user manual for the Jebao Jecod DMP series Smart Wave Maker, detailing installation, operation, app control, wave modes, troubleshooting, and maintenance for aquarium enthusiasts.
Praview Jebao RF-B Series Automatic Feeder User Manual
Comprehensive user manual for the Jebao RF-B Series Automatic Feeder, detailing installation, operation, features, maintenance, and troubleshooting for aquarium fish feeding.
Praview Jebao E Series Wavemaker Pump User Manual
User manual for the Jebao E Series Wavemaker Pump, detailing product features, specifications, installation, operation, maintenance, and troubleshooting.
Praview Buku Panduan Pangguna Pompa Gelombang Aliran Silang Jebao: CP-90, CP-120, CP-150
Buku pituduh pikeun pompa Jebao Cross-Flow Wave, modél CP-90, CP-120, sareng CP-150. Ngawengku pitunjuk kaamanan, pituduh perakitan, operasi kontroler, pangropéa, sareng spésifikasi téknis.
Praview Manual Pangguna Lampu Akuarium Seri Jebao AL & AK - Setelan, Fitur, sareng Kontrol Aplikasi
Buku pituduh lengkep pikeun lampu akuarium Jebao AL sareng AK Series. Ngawengku bubuka produk, spésifikasi, pamasangan, setelan Wi-Fi, unduh sareng kontrol aplikasi, modeu, sareng ngungkulan masalah.