Produk Leuwihview
This document provides essential information for the VULCAN-HART Pilot (Reverse Hood, NAT/LP), part number 109839-3. This pilot assembly is designed for use with natural gas (NAT) or liquid propane (LP) systems in compatible Vulcan-Hart commercial kitchen equipment.

Image: VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3. This image displays the pilot assembly, which includes a metal bracket, a threaded base with a hexagonal nut, and a pilot hood. A separate, smaller gas orifice component is shown to the left.
Fitur konci:
- VULCAN-HART genuine replacement part.
- Top Pilot Burner Kit.
- Part Number: 109839-3.
- Compatible with Natural Gas (NAT) or Liquid Propane (LP) systems.
- Weight: Approximately 0.069 lb (1.12 ounces).
spésifikasi
| Nomer Bagian | 109839-3 |
| Alternate Part Numbers | 109839-1, 409839-1, 409839-3 |
| Gas Type Compatibility | Natural Gas (NAT) or Liquid Propane (LP) |
| Beurat | 0.069 lb (approximately 1.12 ounces) |
| Produsén | VULCAN-HART |
| Nomer Modél Item | 228-1087 |
| UPC | 222810871919 |
Compatible Vulcan-Hart Models:
This pilot assembly is compatible with various Vulcan-Hart models, including but not limited to:
- Ranges/Ovens: SG7830, 7830
- GHM Series: GHM30, GHM30C, GHM45/72, GHM60, GHM60/45, GHM60/72, GHM60T, GHM60T/45, GHM60T/72, GHM72, GHM72/45
- GHXM Series: GHXM60, GHXM60T, GHXM72
- GHX Series: GHX60, GHX60T, GHX72
- GH Series: GH30, GH30C, GH45/72, GH6T45C, GH60, GH60/45, GH60/72, GH60T, GH60T/45, GH60T/72, GH6045C, GH72, GH72/45
Pamasangan
Installation of this pilot assembly should only be performed by a qualified service technician. Improper installation can lead to gas leaks, fire hazards, or equipment damage. Always ensure the gas supply to the appliance is turned off and disconnected before beginning any installation or maintenance procedures.
- Kasalametan munggaran: Disconnect the appliance from all power sources and turn off the main gas supply valve.
- Aksés: Carefully access the pilot assembly area within the appliance, following the specific service manual for your Vulcan-Hart model.
- Ngahapus: Disconnect the old pilot assembly, noting the connections for gas lines and thermocouple/igniter wires.
- Pamasangan: Install the new VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3, ensuring all connections are secure and properly sealed. Verify correct orientation for the reverse hood design.
- Cek Bocor: After installation, turn on the gas supply and perform a thorough leak check using an approved leak detection solution.
- Operasi tés: Restore power and test the pilot ignition and burner operation according to the appliance's service manual.
Refer to your specific Vulcan-Hart appliance service manual for detailed, model-specific installation instructions and safety warnings.
Operasi
The pilot assembly is an internal component responsible for igniting the main burners of your Vulcan-Hart appliance. Its operation is typically automatic once installed and configured correctly. Users interact with the appliance's main controls (e.g., thermostats, burner knobs) to initiate the ignition sequence.
- Ensure the appliance's main gas supply is open.
- Follow the appliance's specific startup procedure, which usually involves turning a control knob to a "Pilot" or "Ignite" position and holding it to allow the pilot to light and heat the thermocouple.
- Once the pilot is established, turn the control knob to the desired operating temperature or burner setting.
If the pilot fails to light or stay lit, refer to the Troubleshooting section or consult a qualified technician.
Pangropéa
Regular maintenance of the pilot assembly ensures reliable operation and extends the lifespan of your appliance. Maintenance should be performed by a qualified technician.
- Inspeksi taunan: Have the pilot assembly inspected annually for signs of wear, corrosion, or blockage.
- beberesih: Ensure the pilot orifice and hood are free from debris, grease, or carbon buildup. A small wire brush or compressed air may be used carefully.
- Flame Check: Verify that the pilot flame is strong, stable, and properly enveloping the thermocouple (if applicable). The flame should typically be blue with a small yellow tip.
- Pariksa komponén: Inspect gas lines for leaks and electrical connections (for igniters/thermocouples) for security and integrity.
Always disconnect power and gas supply before performing any maintenance.
Pamérésan masalah
If you experience issues with your pilot assembly, consider the following common problems. For complex issues, contact a qualified service technician.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pilot moal hurung. | No gas supply; clogged pilot orifice; faulty igniter/thermocouple; incorrect gas pressure. | Check gas supply valve; clean pilot orifice; inspect/replace igniter/thermocouple; verify gas pressure (technician). |
| Pilot lights but will not stay lit. | Faulty thermocouple/thermopile; pilot flame not enveloping thermocouple; low gas pressure. | Adjust pilot flame; inspect/replace thermocouple/thermopile; verify gas pressure (technician). |
| Weak or yellow pilot flame. | Partially clogged pilot orifice; incorrect air mixture; low gas pressure. | Clean pilot orifice; adjust air shutter (if applicable); verify gas pressure (technician). |
Awas: Do not attempt to repair gas components if you are not qualified. Contact a certified gas technician for all gas-related issues.
Garansi sareng Rojongan
For warranty information regarding the VULCAN-HART Pilot (Reverse Hood, NAT/LP) 109839-3, please refer to the documentation provided with your original Vulcan-Hart appliance or contact Vulcan-Hart customer support directly. Keep your purchase receipt for warranty claims.
For technical support or to locate authorized service providers, visit the official Vulcan-Hart website or consult your appliance's user manual.