1. Bubuka
The Inogen One G3 External Battery Charger (Model BA-303) is designed to provide a convenient and efficient method for charging Inogen One G3 standard and extended batteries independently of the Inogen One G3 portable oxygen concentrator. This manual provides essential information for the safe and effective use of your charger.

Image: The Inogen One G3 External Battery Charger with an Inogen One G3 battery inserted, ready for charging.
2. Émbaran Kasalametan
Please read all safety instructions before using the Inogen One G3 External Battery Charger. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Use only with Inogen One G3 standard (BA-300) and extended (BA-316) batteries.
- Ulah ngalaan carjer ka cai atawa Uap kaleuleuwihan.
- Ulah nyobian ngabongkar atawa ngaropéa carjer.
- Ensure the charger is connected to a compatible electrical outlet (100-240V AC, 50-60Hz).
- Jauhkeun carjer tina sumber panas sareng sinar panonpoé langsung.
- If the charger or power cord is damaged, discontinue use immediately and contact customer support.
Bantahan Hukum: Statements regarding dietary supplements have not been evaluated by the FDA and are not intended to diagnose, treat, cure, or prevent any disease or health condition. This product is an accessory for a medical device.
3. Eusi Paket
Pastikeun yén sadaya item aya dina bungkusan:
- Inogen One G3 External Battery Charger (Model BA-303)
- Kabel Input AC
4. Kasaluyuan
This external battery charger is specifically designed for use with Inogen One G3 batteries. It supports both the standard (BA-300) and extended (BA-316) Inogen One G3 battery models.

Image: An accessory compatibility chart showing the Inogen One G3 External Battery Charger (BA-303) is compatible with Inogen One G3 Standard (BA-300) and Extended (BA-316) batteries.
5. Parentah Setup
Follow these steps to set up your Inogen One G3 External Battery Charger:
- Nyambungkeun Daya AC: Plug the AC input cord into an electrical outlet.

Image: Step 1 of the charging process, showing the AC power cord being plugged into a wall outlet.
- Nyambung ka carjer: Plug the other end of the AC input cord into the designated port on the external battery charger.

Image: Step 2 of the charging process, illustrating the AC power cord connected to the external battery charger.
- Selapkeun Batré: Slide your Inogen G3 battery onto the charger until it clicks and locks into place. Ensure it is seated correctly.

Image: Step 3 of the charging process, showing an Inogen G3 battery being slid onto the charger until it locks.
6. Parentah Operasi
Once the charger is set up and a battery is inserted, the charging process will begin automatically.
Indikator Ngecas
- Lampu Beureum Padet: When the battery is correctly positioned on the charger, a solid red light will illuminate, indicating that the battery is actively charging.

Image: Step 4 of the charging process, showing the charger with a solid red light, indicating the battery is charging.
- Lampu héjo: When the green light illuminates, the battery is fully charged and ready for use.

Image: Step 5 of the charging process, showing the charger with a green light, indicating the battery is fully charged.
Waktu Ngecas
Approximate charging times are as follows:
- Standard Inogen One G3 Battery: Up to 5 hours
- Extended Inogen One G3 Battery: Up to 8 hours

Image: The Inogen One G3 External Battery Charger with a battery, illustrating the approximate charging times for standard and extended batteries.
For continuous use, consider having multiple batteries and an additional external charger to ensure batteries are always ready.
7. Pangropéa
The Inogen One G3 External Battery Charger requires minimal maintenance.
- Keep the charger clean and free from dust. Wipe with a dry, soft cloth.
- Ulah make cleaners cair atawa bahan abrasive.
- Simpen carjer dina tempat anu tiis sareng garing upami henteu dianggo.
- Inspect the power cord regularly for any signs of damage.
8. Cara ngungkulan
Upami anjeun mendakan masalah sareng carjer anjeun, tingal masalah sareng solusi umum ieu:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Charger light not illuminating | No power to charger, battery not inserted correctly, or charger malfunction. |
|
| Lampu beureum kedip-kedip | Error during charging process. |
|
| Batré teu pinuh dicas | Battery issue or charger malfunction. |
|
9. Spésifikasi
| Fitur | Rincian |
|---|---|
| Nomer modél | BA-303 |
| Kasaluyuan | Inogen One G3 Standard (BA-300) and Extended (BA-316) Batteries |
| Masukan Voltage | 100-240V AC, 50-60Hz |
| Kaluaran Voltage | 15 volt |
| Ukuran (L x W x H) | 3.3 di x 2.75 di x 1 di. |
| Beurat | 0.12 pon (kira-kira) |
| Standard Battery Charge Time | Nepi ka 5 jam |
| Extended Battery Charge Time | Nepi ka 8 jam |
10. Garansi jeung Rojongan
For warranty information and customer support, please refer to the documentation provided with your original Inogen One G3 portable oxygen concentrator or visit the official Inogen websitus.
Anjeun oge bisa nganjang ka Inogen Store on Amazon pikeun émbaran produk tambahan jeung asesoris.