Altronix AL400ULACM

Altronix ACM Series Access Power Controllers User Manual

Model: AL400ULACM

1. Bubuka

The Altronix AL400ULACM is an 8-fused output power supply and access power controller designed to convert a 115V AC 60Hz input into independently controlled 12V DC or 24V DC outputs. It provides a total of 4 amp at 12VDC or 3 amp at 24V DC continuous supply current.

This unit is engineered to route power to various access control hardware devices, including magnetic locks, electric strikes, and magnetic door holders. Outputs can operate in both Fail-Safe and/or Fail-Secure modes, activated by an open collector sink or normally open (NO) dry trigger input from an access control system, card reader, keypad, push button, or PIR sensor.

The AL400ULACM can be powered by a single common power source for both board operation and locking devices, or by two independent power sources for separate board and lock/accessory power.

2. Fitur konci

3. Setup jeung Instalasi

Carefully unpack the Altronix AL400ULACM unit and inspect for any shipping damage. Ensure all components are present before proceeding with installation.

Altronix AL400ULACM Access Power Controller inside its enclosure, showing the main power supply board, the 8-fused output distribution board, and two sealed lead-acid batteries at the bottom.

Gambar 3.1: Internal view of the Altronix AL400ULACM unit, displaying the power supply board (top), the 8-output distribution board (middle), and two batteries (bottom) within the wall-mountable enclosure. Note the grounding wires connected to the enclosure.

3.1 Pamasangan

Mount the unit securely to a wall or suitable surface using appropriate fasteners. The enclosure is designed for indoor use. Ensure adequate ventilation around the unit.

3.2 Sambungan Wiring

Refer to the wiring diagrams provided with the physical product for detailed connection instructions specific to your application.

4. Parentah Operasi

Once properly installed and wired, the Altronix AL400ULACM operates automatically to provide regulated power to connected devices and manage access control functions.

4.1 Power Conversion and Distribution

The unit converts the incoming 115V AC to either 12V DC or 24V DC, depending on the configuration. This DC power is then distributed through the 8 fused outputs to your connected access control devices.

4.2 Access Control Integration

The outputs are controlled by external trigger inputs. When a valid trigger signal is received from your access control system (e.g., card swipe, keypad entry), the corresponding output will activate, powering or de-powering the connected locking device as configured (Fail-Safe or Fail-Secure mode).

4.3 Operasi Nyadangkeun Batré

In the event of an AC power failure, the unit will automatically and seamlessly switch to battery backup power, ensuring continuous operation of your access control system without interruption or voltage drop. The built-in charger maintains the batteries when AC power is present.

4.4 Fire Alarm Disconnect

If connected to an FACP, the unit can be configured to disconnect power to specific outputs upon receiving a fire alarm signal, facilitating emergency egress as required by safety regulations.

5. Pangropéa

Regular maintenance ensures the longevity and reliable operation of your Altronix AL400ULACM unit.

All maintenance should be performed by qualified personnel with the power disconnected from the unit.

6. Cara ngungkulan

This section provides basic troubleshooting steps for common issues. For more complex problems, contact Altronix technical support.

MasalahMungkin Cukang lantarananaSolusi
Taya kakuatan ka alat disambungkeun.No AC input power; Blown fuse on output; Faulty wiring; Power supply issue.Check AC power source and connections. Inspect and replace any blown fuses. Verify all wiring connections are secure. If problem persists, contact support.
Unit not switching to battery backup.Batteries not connected; Dead or faulty batteries; Battery supervision circuit issue.Ensure batteries are correctly connected with proper polarity. Test batteries and replace if necessary. Check battery supervision contacts.
Output not activating from trigger input.Incorrect trigger wiring; Faulty trigger device; Output configuration issue.Verify trigger input wiring. Test the trigger device (e.g., card reader). Review output configuration settings (Fail-Safe/Fail-Secure).
Unit ieu overheating.Poor ventilation; Overloaded outputs.Ensure adequate airflow around the unit. Reduce load on outputs if exceeding specified current limits.

7. Spésifikasi

ParameterNilai
Nomer modélAL400ULACM
Masukan Voltage115V AC, 60Hz, 1.9 amp dipeunteun
Kaluaran Voltage12V DC or 24V DC (selectable)
Total Output Current (12V DC)4 Amps continuous supply
Total Output Current (24V DC)3 Amps continuous supply
Number of Fused Outputs8
Peunteun sekering3.5 Amp per kaluaran
Batré Charger Ayeuna0.7 Amp (AL400ULXB board)
Batre cocogTwo 12VDC/12AH sealed lead acid or gel type
Ukuran Kandang (W x H x D)12.25" x 15.5" x 4.5" (approx. 16.26 x 13.39 x 5.91 inches package dimensions)
Item Beurat10.09 pon
Suhu Operasi0°C nepi ka 49°C (32°F nepi ka 120°F)
SertifikasiUL Listed, CSFM Approved, MEA Approved

8. Émbaran jaminan

Altronix stands behind the quality and reliability of its products. The AL400ULACM Access Power Controller is backed by a Garansi saumur hirup. For specific terms and conditions of the warranty, please refer to the official Altronix warranty statement or contact Altronix customer service.

9. Rojongan Téknis

Should you require technical assistance or have questions regarding the installation, operation, or maintenance of your Altronix AL400ULACM unit, please contact Altronix technical support directly.

For the most up-to-date contact information, please visit the official Altronix websitus atanapi tingal dokuméntasi anu kalebet sareng produk anjeun.