1. Bubuka
This user manual provides essential information for the proper installation, operation, and maintenance of your Astralpool Fluidra AST4404220101 Pressure Gauge Kit. This kit is designed to accurately measure pressure in compatible pool and spa systems, ensuring optimal performance and safety. Please read this manual thoroughly before use.
2. Émbaran Kasalametan
Salawasna perhatikeun pancegahan kaamanan di handap ieu:
- Ensure the system is depressurized before installing or removing the gauge.
- Do not overtighten connections, as this may damage the gauge or fittings.
- Verify that the gauge's pressure range is suitable for your application.
- Keep the gauge and components away from extreme temperatures or corrosive chemicals.
- If any damage is observed, do not use the kit and contact a qualified technician.
3. Eusi Paket
The Astralpool Fluidra AST4404220101 Pressure Gauge Kit typically includes the following components:
- 1 x Alat Ukur Tekanan
- 1 x T-fitting (plastic)
- 1 x Drain Plug / Bleed Valve (plastic)
- 1 x O-ring / Gasket

4. Setup jeung Instalasi
Follow these steps for proper installation of the pressure gauge kit:
- Sistim depressurize: Before beginning installation, ensure that the pool or spa filtration system is turned off and completely depressurized. This is crucial for safety and to prevent water leakage.
- Tangtukeun Titik Pamasangan: Identify the designated port on your filter or pump housing where the pressure gauge is to be installed. This is typically a threaded opening.
- Prepare T-fitting (if applicable): If your system requires the T-fitting for installation, apply thread sealant (e.g., PTFE tape) to the male threads of the T-fitting. Screw the T-fitting into the designated port on your filter or pump. Do not overtighten.
- Pasang alat ukur tekanan: Apply thread sealant to the brass male threads of the pressure gauge. Carefully screw the pressure gauge into the top port of the T-fitting or directly into the filter/pump housing if no T-fitting is required. Ensure the O-ring is properly seated if it's part of the gauge's connection. Hand-tighten, then use a wrench for a final snug turn, being careful not to overtighten.
- Install Drain Plug: If using the T-fitting, install the plastic drain plug into the remaining open port of the T-fitting. Apply thread sealant if necessary. This plug can also function as a bleed valve.
- Pariksa bocor: Once all components are installed, slowly repressurize the system and carefully check all connections for any signs of water leakage. Tighten connections slightly if leaks are detected.
5. Parentah Operasi
The Astralpool Fluidra AST4404220101 Pressure Gauge is designed for continuous pressure monitoring. Once installed, the gauge will display the current system pressure. Observe the following:
- Tekanan Operasi Normal: Note the normal operating pressure of your system when it is clean and running efficiently. This will serve as your baseline.
- Pressure Readings: Regularly check the pressure reading. A significant increase in pressure above your baseline typically indicates a dirty filter that requires cleaning or backwashing.
- Tekanan turun: A sudden drop in pressure could indicate a blockage in the suction line or a pump issue.
- Hawa getihan: If air is trapped in the system, the drain plug on the T-fitting can often be loosened slightly to bleed air until water flows out, then retightened.
6. Pangropéa
Proper maintenance ensures the longevity and accuracy of your pressure gauge:
- Inspeksi rutin: Periodically inspect the gauge for any signs of physical damage, cracks, or leaks.
- beberesih: Bersihkeun bagian luar alat ukur nganggo lap anu lemes,amp lawon. Ulah make cleaners abrasive atawa pangleyur.
- Winterization: In colder climates, ensure the gauge is drained and protected from freezing temperatures, which can damage the internal mechanism. It may be advisable to remove the gauge during winterization.
- O-ring/Gasket Check: If the gauge is removed for maintenance or winterization, inspect the O-ring or gasket for wear and replace if necessary to ensure a proper seal upon reinstallation.
7. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Gauge reads zero or very low pressure. | System not pressurized; gauge faulty; air in system. | Ensure pump is running and valves are open. Check for blockages. Bleed air from the system. Replace gauge if faulty. |
| Gauge reads abnormally high pressure. | Dirty filter; clogged lines; return line blockage. | Clean or backwash filter. Check and clear any blockages in plumbing. |
| Cai bocor tina sambungan. | Loose connection; damaged O-ring/gasket; insufficient thread sealant. | Depressurize system. Tighten connections. Inspect and replace O-ring/gasket. Reapply thread sealant. |
| Gauge needle is stuck or erratic. | Internal damage; debris inside gauge. | The gauge is likely faulty and requires replacement. |
8. Spésifikasi
| Atribut | Rincian |
|---|---|
| Nomer modél | AST4404220101 |
| merek | Astralpool |
| Produsén | Produk Kolam Astral |
| Bahan | Plastic (fittings), Brass (gauge connection) |
| Ukuran produk (L x W x H) | 1 x 1 x 1 inches (packaging/overall kit dimensions) |
| Item Beurat | 5 pon |
| UPC | 682470355905 |
9. Garansi jeung Rojongan
For specific warranty information regarding your Astralpool Fluidra AST4404220101 Pressure Gauge Kit, please refer to the documentation provided with your purchase or contact Astral Pool Products directly. Support may also be available through your authorized dealer or installer.
Inpormasi Kontak Pabrikan:
- Pabrikan: Produk Kolam Astral
- Please visit the official Astralpool websitus pikeun detil kontak sareng sumber pangrojong panganyarna.





