1. Bubuka

This user manual provides essential information for the proper installation, operation, and maintenance of your Astralpool Fluidra AST4404220101 Pressure Gauge Kit. This kit is designed to accurately measure pressure in compatible pool and spa systems, ensuring optimal performance and safety. Please read this manual thoroughly before use.

2. Émbaran Kasalametan

Salawasna perhatikeun pancegahan kaamanan di handap ieu:

3. Eusi Paket

The Astralpool Fluidra AST4404220101 Pressure Gauge Kit typically includes the following components:

Astralpool Pressure Gauge Kit components including a pressure gauge, a black T-fitting, a black drain plug, and a black O-ring.
Figure 1: Components of the Astralpool Fluidra AST4404220101 Pressure Gauge Kit. The image displays the main pressure gauge unit, a black plastic T-shaped connector, a black plastic threaded plug, and a small black rubber O-ring.

4. Setup jeung Instalasi

Follow these steps for proper installation of the pressure gauge kit:

  1. Sistim depressurize: Before beginning installation, ensure that the pool or spa filtration system is turned off and completely depressurized. This is crucial for safety and to prevent water leakage.
  2. Tangtukeun Titik Pamasangan: Identify the designated port on your filter or pump housing where the pressure gauge is to be installed. This is typically a threaded opening.
  3. Prepare T-fitting (if applicable): If your system requires the T-fitting for installation, apply thread sealant (e.g., PTFE tape) to the male threads of the T-fitting. Screw the T-fitting into the designated port on your filter or pump. Do not overtighten.
  4. Pasang alat ukur tekanan: Apply thread sealant to the brass male threads of the pressure gauge. Carefully screw the pressure gauge into the top port of the T-fitting or directly into the filter/pump housing if no T-fitting is required. Ensure the O-ring is properly seated if it's part of the gauge's connection. Hand-tighten, then use a wrench for a final snug turn, being careful not to overtighten.
  5. Install Drain Plug: If using the T-fitting, install the plastic drain plug into the remaining open port of the T-fitting. Apply thread sealant if necessary. This plug can also function as a bleed valve.
  6. Pariksa bocor: Once all components are installed, slowly repressurize the system and carefully check all connections for any signs of water leakage. Tighten connections slightly if leaks are detected.

5. Parentah Operasi

The Astralpool Fluidra AST4404220101 Pressure Gauge is designed for continuous pressure monitoring. Once installed, the gauge will display the current system pressure. Observe the following:

6. Pangropéa

Proper maintenance ensures the longevity and accuracy of your pressure gauge:

7. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Gauge reads zero or very low pressure.System not pressurized; gauge faulty; air in system.Ensure pump is running and valves are open. Check for blockages. Bleed air from the system. Replace gauge if faulty.
Gauge reads abnormally high pressure.Dirty filter; clogged lines; return line blockage.Clean or backwash filter. Check and clear any blockages in plumbing.
Cai bocor tina sambungan.Loose connection; damaged O-ring/gasket; insufficient thread sealant.Depressurize system. Tighten connections. Inspect and replace O-ring/gasket. Reapply thread sealant.
Gauge needle is stuck or erratic.Internal damage; debris inside gauge.The gauge is likely faulty and requires replacement.

8. Spésifikasi

AtributRincian
Nomer modélAST4404220101
merekAstralpool
ProdusénProduk Kolam Astral
BahanPlastic (fittings), Brass (gauge connection)
Ukuran produk (L x W x H)1 x 1 x 1 inches (packaging/overall kit dimensions)
Item Beurat5 pon
UPC682470355905

9. Garansi jeung Rojongan

For specific warranty information regarding your Astralpool Fluidra AST4404220101 Pressure Gauge Kit, please refer to the documentation provided with your purchase or contact Astral Pool Products directly. Support may also be available through your authorized dealer or installer.

Inpormasi Kontak Pabrikan:

Dokumén Patali - AST4404220101

Praview Sicherheitsdatenblatt ASTRALPOOL 0037-Claritab Ditambah
Sicherheitsdatenblatt für ASTRALPOOL 0037-Claritab Plus, ein Flockungsmittel zur Wasseraufbereitung. Enthält Informationen zu Gefahren, Handhabung, Lagerung und Erste-Hilfe-Maßnahmen gemäß EU-Verordnung 2020/878.
Praview Sicherheitsdatenblatt ASTRALPOOL Flockbag (11390) - Gefahren, Handhabung und Entsorgung
Umfassendes Sicherheitsdatenblatt für ASTRALPOOL Flockbag (11390), das detaillierte Informationen zu Gefahren, Handhabung, Lagerung, Erste Hilfe, Brandbekämpfung und Entsorgung gemäß EU-Verordnung 2020/878 bereitstellt.
Praview AstralPool Viron Salt Chlorinator with Bluetooth: Installation and Operating Manual
Comprehensive installation, operation, and maintenance guide for the AstralPool Viron Salt Chlorinator with Bluetooth. Learn setup, troubleshooting, and pool chemistry management.
Praview AstralPool E25 & E35 Salt Chlorinator Instalasi jeung Parentah Operasi
instalasi komprehensif sarta parentah operasi pikeun AstralPool E25 & E35 Salt Chlorinator. Diajar ngeunaan setelan, program, pangropéa, sareng ngungkulan pikeun sanitasi kolam renang optimal.
Praview Astralpool LumiPlus Plug&Play Remote Control: User Manual, Pairing Guide, and EU Declaration of Conformity
Comprehensive guide for the Astralpool LumiPlus Plug&Play Remote Control (model 74399). Includes step-by-step pairing instructions, features, safety warnings, range details, and the EU Declaration of Conformity from SACOPA SAU. Compatible with LumiPlus Plug&Play LED projectors.
Praview Astralpool LumiPlus Essential PAR56 Underwater LED Lamp - Installation & Maintenance Guide
This document provides installation and maintenance instructions for the Astralpool LumiPlus Essential PAR56 underwater LED lamp. It details general characteristics, installation steps, electrical connections, operation modes, safety warnings, and technical specifications for both monocolor and RGB models.