1. Bubuka
This manual provides essential information for the safe and effective installation, operation, and maintenance of the Beckett 51771u Ignitor with Beckett "A" Base. The Beckett 51771u is a critical component designed for use in gas and oil burners, primarily in residential and commercial HVAC applications. This ignitor is manufactured by Beckett, a leading provider of burner components.
Fitur utama produk ieu kalebet:
- Beurat barang: 2.0 lb
- Nagara Asal: Amérika Sarikat
- Brand name: Beckett
- Item Dimensions: 5.0"L x 5.0"W x 5.0"H
2. Émbaran Kasalametan
PERHATOSAN: Installation and servicing of this ignitor must be performed by a qualified technician. Failure to follow these instructions could result in property damage, personal injury, or death.
- Always disconnect power to the appliance before installing, servicing, or removing the ignitor.
- Ensure proper grounding of the appliance and all electrical connections.
- Verify that all wiring connections comply with local electrical codes and the appliance manufacturer's specifications.
- Do not operate the appliance if any part of the ignitor is damaged or appears to be leaking.
- Wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, during installation and servicing.
3. Eusi Paket
Upon opening the package, verify that all components are present and undamaged. The Beckett 51771u Ignitor package typically includes:
- 1 x Beckett 51771u Ignitor with "A" Base
- Hardware dipasang (screws, klip)
- Lembar instruksi (manual ieu)

Figure 1: The Beckett 51771u Ignitor, showing the black base, two white ceramic insulators with metal springs, and attached white and blue electrical wires with red spade connectors.
4. Setup jeung Instalasi
The Beckett 51771u Ignitor is designed for straightforward replacement in compatible Beckett "A" base systems. Follow these general steps for installation:
- Pegatkeun daya: Before beginning any work, ensure the main power supply to the furnace or burner is completely disconnected at the circuit breaker or fuse box. Verify with a voltage panguji.
- Access Old Ignitor: Locate the existing ignitor on your burner. It is typically mounted near the nozzle assembly.
- Pegatkeun sambungan kabel: Carefully disconnect the electrical wires from the old ignitor. Note the polarity if applicable (e.g., white wire to neutral).
- Remove Old Ignitor: Unscrew or unclip the old ignitor from its mounting base.
- Install New Ignitor: Position the new Beckett 51771u Ignitor onto the "A" base. Secure it using the provided screws and clips. Ensure it is firmly seated.
- Sambungkeun Wiring: Connect the electrical wires to the new ignitor. For the Beckett 51771u, ensure the white wire is connected to the neutral (common) terminal. The other wire (blue/white stripe or black, depending on the specific model) connects to the hot lead. Use appropriate connectors if necessary.
- Pariksa sambungan: Double-check all electrical and mechanical connections for tightness and correctness.
- Mulangkeun Daya: Saatos pamasangan réngsé sareng diverifikasi, hurungkeun deui daya ka alat.
- Operasi tés: Initiate a test firing of the burner to ensure the new ignitor functions correctly and provides a strong, consistent spark for ignition.
Catetan: Upami anjeun teu yakin kana léngkah naon waé, konsultasi ka teknisi HVAC anu mumpuni.
5. Operasi
The Beckett 51771u Ignitor is an electronic solid-state device designed to replace older iron core ignition transformers. Its primary function is to generate a high-voltage spark to ignite the fuel (oil or gas) in the burner. When the burner control calls for heat, the ignitor receives power and produces a continuous spark across its electrodes, initiating combustion. This unit provides a strong, consistent spark for reliable burner startup.
6. Pangropéa
Regular maintenance of your heating system is crucial for optimal performance and longevity of components, including the ignitor. While the ignitor itself requires minimal direct maintenance, consider the following:
- Inspeksi taunan: Have your heating system professionally inspected annually. The technician will check the ignitor's performance, electrode condition, and wiring.
- Kabersihan: Ensure the area around the ignitor is free from dust, debris, or oil residue, which can interfere with its operation.
- Electrode Gap: The ignitor's electrodes should maintain the correct gap as specified by the burner manufacturer. This is typically checked during professional servicing.
- Integritas kabel: Periodically check the ignitor's wiring for any signs of wear, fraying, or loose connections.
7. Cara ngungkulan
If your burner is not igniting, the ignitor may be a contributing factor. Here are some common troubleshooting steps:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Burner gagal hurung | No spark or weak spark from ignitor. |
|
| Burner ignites, but cycles off quickly | Intermittent spark or flame sensor issue. |
|
| Sooty or smelly startup | Delayed ignition or improper air/fuel mixture. |
|
For complex issues, it is highly recommended to contact a certified HVAC technician.
8. Spésifikasi
| Atribut | Rincian |
|---|---|
| Produsén | Perusahaan Suplai APR |
| Nomer Bagian | 51771U |
| Item Beurat | 1.49 pon |
| Dimensi produk | 5 x 5 x 5 inci |
| Nomer Modél Item | 51771u |
| Warna | Hideung Padet |
| Item Paket Kuantitas | 1 |
| Komponén Kaasup | Tools (Ignitor) |
| Batré Kaasup? | No |
| Batré Diperlukeun? | No |
| Tanggal Kahiji Sadia | 15 Januari 2014 |
9. Garansi jeung Rojongan
Specific warranty terms for the Beckett 51771u Ignitor are provided by the manufacturer, Beckett, or the distributor at the time of purchase. Please refer to your purchase documentation or contact Beckett directly for detailed warranty information.
For technical support, installation assistance, or to inquire about replacement parts, please contact Beckett customer service or a qualified HVAC professional.
You can find more information about Beckett products and support on their official websitus: www.beckettcorp.com