DIMPLEX CUH05B31T

DIMPLEX CUH05B31T Compact Industrial Unit Heater Instruction Manual

Model: CUH05B31T

Merek: DIMPLEX

1. Produk Langkungview

The DIMPLEX CUH05B31T is a compact industrial unit heater designed for efficient heating in various indoor environments such as workshops and garages. It features a robust construction with a stainless-steel sheathed heating element, adjustable louvers for precise airflow direction, and a built-in single-pole bulb thermostat for temperature regulation. The unit also incorporates a fan-delay function to utilize residual heat and a power interrupt thermal cut-out for overheat protection.

DIMPLEX CUH05B31T Compact Industrial Unit Heater, Gray

Figure 1: DIMPLEX CUH05B31T Compact Industrial Unit Heater with mounting bracket.

2. Émbaran Kasalametan penting

Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in fire, electric shock, personal injury, or property damage. Retain this manual for future reference.

  • Pamasangan listrik: All electrical wiring and connections must be performed by a qualified, licensed electrician in accordance with national and local electrical codes.
  • Sasayogian tanaga: Ensure the heater is connected to a dedicated 240V circuit with appropriate amperage (typically 40A) and wire gauge (4-8 AWG copper wire).
  • Grounding: The heater must be properly grounded to prevent electrical shock.
  • Clearances: Maintain adequate clearance from combustible materials (walls, furniture, curtains, etc.) as specified in the installation section.
  • Perlindungan overheat: The unit is equipped with a power interrupt thermal cut-out that will automatically shut off the heater if it overheats. If this occurs, turn off the power, allow the unit to cool, and inspect for obstructions before restarting.
  • lokasi: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used.
  • Uap: Do not expose the heater to water or excessive moisture. This unit is for indoor use only.

3. Eusi Paket

Pastikeun yén sadaya item anu didaptarkeun di handap kalebet kana pakét anjeun:

  • DIMPLEX CUH05B31T Unit Heater
  • Swivel Pamasangan Bracket
  • Installation Hardware (lag bolts, nuts, washers)
  • Power Cord (pigtail)
  • Instruksi Manual

4. Pamasangan

4.1 Pasang Pamanas

The DIMPLEX CUH05B31T can be mounted on a ceiling or wall using the included swivel bracket. Ensure the mounting surface is structurally sound and capable of supporting the heater's weight (13.2 lbs) plus any additional stress from operation.

  1. Select a suitable mounting location, ensuring proper clearances from combustible materials (refer to safety guidelines).
  2. Attach the swivel mounting bracket to the chosen surface using the provided lag bolts and appropriate tools. Ensure the bracket is securely fastened.
  3. Align the heater with the bracket and secure it using the large knobs on the sides of the unit. These knobs allow for adjustment of the heater's angle.
  4. Tighten the smaller knobs to fix the heater at the desired angle. The bracket offers multiple angle positions for optimal heat distribution.

4.2 Sambungan Listrik

WARNING: Electrical installation must be performed by a qualified, licensed electrician. Ensure power is disconnected at the main circuit breaker before proceeding.

  1. Locate the electrical access panel on the side of the heater. Remove the retaining screw and open the panel.
  2. Identify the knockout on the side of the heater's casing. Use appropriate tools to remove the knockout.
  3. Install the provided grommet with integral strain relief into the knockout opening.
  4. Feed the power cord (pigtail) through the strain relief.
  5. Connect the wires to the terminal block inside the heater:
    • Connect the Black Wire to L1.
    • Connect the Red Wire to L2.
    • Connect the Green Wire to the Ground terminal.
  6. Ensure all wire connections are secure and that no insulation is under the terminals.
  7. Tighten the strain relief to prevent the power cord from pulling out or being damaged.
  8. Close the electrical access panel and secure it with the retaining screw.

4.3 Adjusting Louvers

The heater features adjustable louvers on the front. These can be manually adjusted to direct the warm airflow to specific areas within your space. Gently move each louver to achieve the desired airflow pattern.

5. Parentah Operasi

The DIMPLEX CUH05B31T is equipped with a built-in single-pole bulb thermostat for temperature control and a fan delay function.

  1. Daya Hurung: Ensure the heater is properly installed and connected to the power supply. Locate the main power switch/button (typically a red indicator) on the unit and turn it ON.
  2. Setel Suhu: Use the built-in single-pole bulb thermostat to set your desired temperature. Rotate the thermostat dial to increase or decrease the temperature setting. The heater will operate until the set temperature is reached, then cycle on and off to maintain it.
  3. Fungsi reureuh kipas: The fan delay function allows the fan to continue running for a short period after the heating element turns off. This utilizes residual heat, improving efficiency and ensuring all generated heat is distributed.
  4. Perlindungan overheat: In the event of overheating, the power interrupt thermal cut-out will activate, shutting down the heater. If this occurs, turn off the heater, allow it to cool down, and check for any obstructions to airflow before restarting.

6. Pangropéa

Pangropéa rutin mastikeun kinerja anu optimal sareng umur panjang pemanas anjeun. Salawasna pegatkeun listrik sateuacan ngalakukeun pangropéa naon waé.

  • beberesih: périodik ngabersihan exterior tina manaskeun jeung lemes, damp cloth. Do not use abrasive cleaners or solvents. Ensure the air intake and exhaust areas are free from dust and debris.
  • Sambungan listrik: Annually, have a qualified electrician inspect all electrical connections for tightness and signs of wear or damage.
  • Louvers: Ensure the adjustable louvers move freely and are not obstructed.

7. Cara ngungkulan

If your heater is not operating correctly, consult the following table for common issues and solutions. If the problem persists, contact a qualified electrician or DIMPLEX customer support.

MasalahMungkin Cukang lantarananaSolusi
Pemanas teu hurung.Taya catu daya.Check circuit breaker and electrical connections. Ensure main power switch is ON.
Pemanas ngahasilkeun panas anu teu cekap.Thermostat disetel handap teuing.Ningkatkeun setelan thermostat.
Obstruction to airflow.Clear any obstructions from air intake or exhaust.
Pemanas pareum teu disangka-sangka.Perlindungan overheat diaktipkeun.Turn off heater, allow to cool, check for obstructions, then restart.
Kipas teu beroperasi.Fan delay in effect or motor issue.Wait for fan delay cycle to complete. If still not working, contact service.

8. Spésifikasi

FiturRincian
merekDIMPLEKS
Nomer modélCUH05B31TG
Kaluaran Panas3750/5000 Watt
Voltage240 Volts (Recommended for 5000W operation)
Laju Aliran Udara200 CFM
Fitur hususPerlindungan overheat
Warnakulawu
Faktor BentukWall or Ceiling Mountable
Pamakéan jero rohangan / outdoorjero rohangan
Dimensi produk9 "D x 11" W x 9" H
Dianjurkeun MangpaatGarage, Workshop
Tipe PamasanganGunung siling, témbok Gunung
Tipe SuluhListrik
Item Beurat13.2 pon
UPC785934133801, 781052053441

9. Garansi jeung Rojongan

This DIMPLEX CUH05B31T Compact Industrial Unit Heater comes with a 1-year warranty on the complete unit ti tanggal beuli. Garansi ieu nyertakeun cacad dina bahan sareng pagawean dina panggunaan sareng jasa normal.

For warranty claims, technical support, or service inquiries, please contact DIMPLEX customer support. Keep your proof of purchase for warranty validation.

Dokumén Patali - CUH05B31T

Praview Dimplex Compact Unit Heater CUH05B31T Practical User's Guide
Practical user's guide for the Dimplex Compact Unit Heater, Model CUH05B31T, covering installation, operation, maintenance, and warranty information.
Praview Dimplex BFH24E Base Unit Fan Heater: Installation and Operating Manual
Comprehensive instruction manual for the Dimplex BFH24E Base Unit Fan Heater. Covers installation, operation, safety guidelines, remote control usage, technical specifications, and warranty information.
Praview Dimplex 2kW DC Keramik Tower manaskeun DHCH20E Instruksi Manual
Instruksi manual pikeun Dimplex 2kW DC keramik Tower manaskeun kalawan kadali éléktronik (Model DHCH20E). Ngawengku pancegahan kaamanan, operasi, spésifikasi, beberesih, neundeun, pangropéa, garansi, sareng inpormasi daur ulang.
Praview Dimplex Futurad manaskeun: FutM2CE & FutM3CE Manual pamaké sarta Guide Kasalametan
Manual pamaké komprehensif pikeun pamanas Dimplex Futurad (model FutM2CE jeung FutM3CE). Ngawengku parentah kaamanan, operasi, assembly, fitur kawas timer runback jeung panyalindungan ibun, spésifikasi teknis, sarta informasi jaminan.
Praview Dimplex Alta WiFi Panel Pemanas: Pamasangan, Operasi, sareng Jaminan
Instalasi resmi jeung parentah operasi pikeun Dimplex Alta WiFi Panel manaskeun (Model 300002588). Ngawengku naséhat kaamanan, spésifikasi téknis, data efisiensi énergi, pituduh ngamimitian gancang, konektipitas aplikasi, sareng inpormasi garansi.
Praview Dimplex EUH-B Series Electric Unit Heaters: Installation, Operation, and Warranty Guide
This guide provides comprehensive information on Dimplex EUH-B Series electric unit heaters, including important safety instructions, installation procedures, operation details, maintenance guidelines, warranty information, and a list of replacement parts. It is designed for industrial and commercial applications.