DIMPLEX XT9605

Dimplex XT9605 Charge Control Thermostat User Manual

For Dimplex XL Storage Heaters (Pre-October 2001 Models)

1. Bubuka

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Dimplex XT9605 Charge Control Thermostat. This thermostat is specifically designed as a replacement for older, larger thermostats found in Dimplex XL storage heaters manufactured before October 2001. Please read these instructions thoroughly before proceeding with any installation or operation.

1.1 Émbaran Kasalametan

  • Always disconnect the main power supply to the storage heater before attempting any installation, maintenance, or repair work. Failure to do so can result in electric shock or serious injury.
  • Installation should only be performed by a qualified electrician or competent person.
  • Ensure all connections are secure and comply with local wiring regulations.
  • Ulah ngoperasikeun termostat upami katingalina ruksak.

2. Setup jeung Instalasi

The Dimplex XT9605 thermostat is designed for straightforward replacement of existing units. It comes with new fixings, which may have different thread types than your old thermostat. Exercise caution and do not force connections.

2.1 Persiapan

  1. Pegatkeun Daya: Locate the main power switch for your Dimplex XL storage heater and turn it OFF. Verify that the power is off using a suitable voltage panguji.
  2. Access Thermostat: Taliti miceun bagian luar casing or access panel of your storage heater to expose the existing thermostat. Refer to your specific heater's manual for detailed access instructions.

2.2 Prosedur ngagantian

  1. Leupaskeun Thermostat Old: Disconnect the wiring from the old thermostat, noting the position of each wire. It is recommended to take a photograph before disconnecting. Unscrew and remove the old thermostat.
  2. Pasang Termostat Anyar: Position the new Dimplex XT9605 thermostat in the designated location. Use the provided new fixings to secure it. Ensure the thermostat is firmly mounted.
  3. Sambungkeun Wiring: Reconnect the wiring to the new thermostat according to the previous configuration. Double-check all connections for tightness and correctness.
Dimplex XT9605 Charge Control Thermostat with mounting screws
Figure 1: The Dimplex XT9605 Charge Control Thermostat, shown with its included mounting screws. This image displays the component's overall structure and connection points.

2.3 Léngkah ahir

  1. Pasang deui Pemanas: Replace the access panel or outer casing of the storage heater, ensuring all screws are tightened.
  2. Mulangkeun Daya: Turn the main power supply to the storage heater back ON.
  3. Operasi tés: Proceed to the Operating section to test the thermostat's functionality.

3. Parentah Operasi

The Dimplex XT9605 thermostat controls the charge level of your Dimplex XL storage heater, influencing how much heat is stored during off-peak hours. The thermostat features a push-button type controller for setting adjustments.

Ti luhur ka handap view of Dimplex XT9605 Thermostat
Gambar 2: A luhur-handap view of the Dimplex XT9605 thermostat, highlighting the central control mechanism and mounting brackets.

3.1 Setting the Charge Level

The specific method for adjusting the charge level will depend on the design of your Dimplex XL heater's control panel, which interacts with this thermostat. Generally, you will find a dial or button on the heater's fascia that corresponds to the thermostat's setting. Consult your heater's user manual for precise instructions on how to adjust the charge control.

  • A higher setting typically results in more heat stored, providing warmth for a longer duration.
  • A lower setting results in less heat stored, which can save energy if less heat is required.

Allow time for the heater to cycle through a full charge period (usually overnight) to observe the effect of any adjustments.

4. Pangropéa

The Dimplex XT9605 Charge Control Thermostat is designed for reliable operation and requires minimal maintenance. Regular checks of the storage heater itself are recommended.

  • beberesih: Ensure the area around the thermostat within the heater is free from dust and debris. Always disconnect power before cleaning.
  • Inspeksi Visual: Periodically inspect the thermostat and its wiring for any signs of damage, loose connections, or overheating. If any issues are observed, disconnect power and consult a qualified technician.

5. Cara ngungkulan

If your Dimplex XL storage heater is not functioning as expected after thermostat replacement, consider the following:

  • Teu Aya Panas/Teu Cukup Panas:
    • Sasayogian tanaga: Ensure the main power supply to the heater is ON.
    • Setélan termostat: Verify that the charge control setting on your heater is not set too low.
    • Wiring: Double-check all wiring connections to the thermostat for correctness and tightness. Loose connections can prevent proper operation.
  • Overheating:
    • Setélan termostat: Ensure the charge control setting is not excessively high for your heating needs.
    • Thermostat Fault: If the heater consistently overheats regardless of settings, the thermostat may be faulty and require replacement.
  • Ruksakna Fisik: If the thermostat or its components appear physically damaged, it must be replaced.

For persistent issues, it is recommended to contact a qualified electrician or the manufacturer for assistance.

6. Spésifikasi

FiturRincian
merekDIMPLEKS
Nomer modélXT9605
Warnakulawu
Voltage240 volt
Bahanlogam
Item Beurat99.8 g
Tipe ControllerPencét-tombol
Kagunaan Produk HususResidential heating (Dimplex XL Night Storage Heater)
Tipe Kontrol SuhuPemanasan
Téhnologi konektipitasDikabel
Sumber DayaKabel Listrik
ProdusénDintlex
Negara asalCina
Samping view of Dimplex XT9605 Thermostat
Figure 3: A side perspective view of the Dimplex XT9605 thermostat, showing its compact design and internal components.

7. Garansi jeung Rojongan

Information regarding the specific warranty period for the Dimplex XT9605 Charge Control Thermostat was not provided. Please refer to your purchase documentation or contact the retailer from whom you purchased the product for warranty details.

For technical support or further assistance, please contact the manufacturer, Dimplex, or the authorized seller. Contact information can typically be found on the product packaging or the seller's websitus.

Dokumén Patali - XT9605

Praview Dimplex 2kW DC Keramik Tower manaskeun DHCH20E Instruksi Manual
Instruksi manual pikeun Dimplex 2kW DC keramik Tower manaskeun kalawan kadali éléktronik (Model DHCH20E). Ngawengku pancegahan kaamanan, operasi, spésifikasi, beberesih, neundeun, pangropéa, garansi, sareng inpormasi daur ulang.
Praview Dimplex Futurad manaskeun: FutM2CE & FutM3CE Manual pamaké sarta Guide Kasalametan
Manual pamaké komprehensif pikeun pamanas Dimplex Futurad (model FutM2CE jeung FutM3CE). Ngawengku parentah kaamanan, operasi, assembly, fitur kawas timer runback jeung panyalindungan ibun, spésifikasi teknis, sarta informasi jaminan.
Praview Dimplex Alta WiFi Panel Pemanas: Pamasangan, Operasi, sareng Jaminan
Instalasi resmi jeung parentah operasi pikeun Dimplex Alta WiFi Panel manaskeun (Model 300002588). Ngawengku naséhat kaamanan, spésifikasi téknis, data efisiensi énergi, pituduh ngamimitian gancang, konektipitas aplikasi, sareng inpormasi garansi.
Praview Dimplex Oil-Filled Column Heaters: User Manual, Safety, and Specifications
Comprehensive user manual for Dimplex OFC series oil-filled column heaters, detailing operation, safety precautions, timer functions, fitting castors, cleaning, warranty, and technical specifications.
Praview Dimplex DIR Series Indoor/Outdoor Infrared Heaters User Manual
User manual for Dimplex DIR Series Indoor/Outdoor Infrared Heaters (models DIR15A10GR, DIR18A10GR, DIR22A10GR, DIR30A10GR). Includes installation, operation, safety, maintenance, and troubleshooting guides.
Praview Dimplex WFE 3TNB/WFE 3TNS Wall-mounted Fan Convector Installation and Operating Instructions
Installation and operating instructions for the Dimplex WFE 3TNB and WFE 3TNS wall-mounted fan convector heater. Includes safety advice, installation, electrical connections, operation, timer programming, and maintenance.