Hewlett Packard 337972-B21

HP Smart Array P600 RAID Controller User Manual

Model: 337972-B21 | Brand: Hewlett Packard

1. Bubuka

The HP Smart Array P600 serial attached SCSI (SAS) controller is designed to enhance performance and reliability for HP servers. This advanced RAID controller supports the latest SCSI technology and offers robust RAID capabilities. As a new generation SAS Smart Array controller, the SA-P600 significantly improves data transfer rates, providing twice the bandwidth of a 4-channel U320 array controller. This manual provides essential information for the installation, operation, maintenance, and troubleshooting of your HP Smart Array P600 controller.

HP Smart Array P600 RAID Controller card with various components visible.

Figure 1: HP Smart Array P600 RAID Controller

This image displays the HP Smart Array P600 RAID Controller card. Key components visible include the PCI-X connector at the bottom, SAS ports (labeled PORT-1 and PORT-2) for connecting SAS drives, and a 256MB SDRAM module for cache memory. The card also features various integrated circuits, including LSI Logic and ARM processors, and a 3.6V Ni-MH Battery Pack for cache backup. The overall design is a green circuit board with numerous electronic components, indicating its function as a high-performance storage controller.

2. Setup jeung Instalasi

Proper installation is crucial for the optimal performance of your HP Smart Array P600 controller. Follow these steps carefully:

  1. Pancegahan Kasalametan: Before beginning, ensure the server is powered off and disconnected from all power sources. Wear an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to components.
  2. Locate PCI-X Slot: Identify an available PCI-X slot on your server's motherboard. The HP Smart Array P600 is designed for PCI-X interfaces.
  3. Insert Controller Card: Carefully align the controller card with the PCI-X slot. Apply even pressure to both ends of the card until it is fully seated in the slot. Secure the card with the retaining clip or screw provided by your server chassis.
  4. Connect SAS Cables: Connect the appropriate SAS data cables from your SAS hard drives or SAS backplane to the SAS ports (PORT-1, PORT-2) on the HP Smart Array P600 controller. Ensure connections are secure.
  5. Connect Battery Backup Unit (BBU): If your model includes a Battery Backup Unit (BBU) for cache protection, ensure it is properly connected to the controller. The 3.6V Ni-MH Battery Pack (HP Spares# 307132-001, HP Part# 274779-001) is typically pre-attached or requires a simple connection.
  6. Close Server Chassis: Once all connections are secure, close the server chassis cover.
  7. Hurungkeun sareng Konpigurasikeun: Reconnect power to the server and power it on. During the server's boot process, access the Smart Array controller's BIOS or utility to configure RAID arrays and logical drives. Refer to your server's documentation for specific instructions on accessing the controller utility.

3. Operasi jeung Konfigurasi

Operating the HP Smart Array P600 involves configuring and managing your storage arrays. This is typically done through the controller's firmware utility or a software management application.

  • Accessing the Controller Utility: During server boot-up, a prompt usually appears (e.g., "Press F8 to enter Option ROM Configuration for Arrays"). Follow the on-screen instructions to enter the utility.
  • Creating Logical Drives:
    • Select the physical drives you wish to include in your array.
    • Choose the desired RAID level (e.g., RAID 0, RAID 1, RAID 5, RAID 10). The P600 supports various RAID levels for performance and data redundancy.
    • Define the logical drive size and other parameters as needed.
  • Managing Arrays: The utility allows you to perform tasks such as:
    • Expanding existing logical drives.
    • Adding spare drives.
    • Monitoring drive status and array health.
    • Performing consistency checks.
  • Pamasangan supir: After configuring the arrays, install the appropriate operating system drivers for the HP Smart Array P600 controller. These drivers are typically available on the HP support website or included with your server's driver disc.

4. Pangropéa

Regular maintenance helps ensure the longevity and reliability of your HP Smart Array P600 controller and the data it manages.

  • Pembaruan firmware: Pariksa périodik rojongan HP websitus for the latest firmware updates for your P600 controller. Firmware updates can provide performance improvements, bug fixes, and enhanced compatibility.
  • Pembaruan supir: Keep your operating system drivers for the controller up-to-date.
  • Battery Backup Unit (BBU) Monitoring: The 3.6V Ni-MH Battery Pack provides cache protection. Monitor its status through the controller utility. If the battery shows signs of degradation or failure, it should be replaced promptly to ensure data integrity during power outages. The part number for the battery is HP Part# 274779-001 or HP Spares# 307132-001.
  • Inspeksi Fisik: During server maintenance, visually inspect the controller card for any signs of dust buildup, loose connections, or physical damage. Ensure proper airflow around the card.
  • Cadangan Data: While RAID provides data redundancy, it is not a substitute for regular data backups. Always maintain a comprehensive backup strategy for critical data.

5. Cara ngungkulan

This section provides solutions to common issues you might encounter with your HP Smart Array P600 controller.

MasalahMungkin Cukang lantarananaSolusi
Controller not detected by server.
  • Card not seated properly.
  • Faulty PCI-X slot.
  • Kagagalan controller.
  • Reseat the controller card firmly in the PCI-X slot.
  • Try a different PCI-X slot if available.
  • Test the controller in another compatible server if possible.
Drives not detected by controller.
  • Loose or faulty SAS cables.
  • Drives not powered.
  • Faulty drives.
  • Check and reseat all SAS data and power cables.
  • Ensure drives are receiving power.
  • Test drives individually if possible.
RAID array degraded or failed.
  • Kagagalan drive.
  • Controller error.
  • Identify and replace the failed drive(s). The array should rebuild automatically if hot-spare is configured or manual rebuild is initiated.
  • Check controller logs for specific error codes.
Performance issues.
  • Outdated firmware/drivers.
  • Incorrect RAID level for workload.
  • Overheating.
  • Update controller firmware and drivers.
  • Review Konfigurasi RAID.
  • Ensure adequate server cooling.

6. Spésifikasi

The following are key specifications for the HP Smart Array P600 controller:

  • merek: Hewlett Packard
  • Jumlah modél: 337972-B21
  • Antarmuka Hardware: PCI-X, SAS
  • Ukuran produk: 18.5 x 7.5 x 3 inci
  • Beurat barang: 2 pon
  • Alat anu cocog: Desktop (Servers)
  • Nomer Saham Nasional: 7025-01-549-2913
  • Titimangsa munggaran sadia: Pébruari 15, 2006
  • Pabrikan: Hewlett Packard (Consumables)
  • Basa: Inggris
  • Cadangan batré: 3.6V Ni-MH Battery Pack (HP Spares# 307132-001, HP Part# 274779-001)
  • Cache Memory: 256 MB SDRAM

7. Pangrojong sareng Jaminan

For technical assistance, driver downloads, firmware updates, and additional product information, please visit the official HP support website. While specific warranty details for this product may vary based on purchase date and region, HP typically provides support resources for its enterprise hardware.

  • Toko Resmi HP: For product information and related accessories, visit the Toko HP di Amazon.
  • General HP Support: For comprehensive support resources, including documentation and troubleshooting guides, please refer to the main HP support portal (search for "HP Support" online).
  • Kabijakan pamulangan: The buybox winner indicates a 30-day refund/replacement return policy. Please verify with your seller for specific return terms.

© 2004 Hewlett-Packard Development Company, L.P. All rights reserved. This manual is for informational purposes only.