OPTIMA 34/78

OPTIMA 34/78 RedTop Battery User Manual

Sealed AGM Car, Truck, and SUV Starting Battery

1. Bubuka

This manual provides essential information for the safe and effective use of your OPTIMA 34/78 RedTop Sealed AGM Starting Battery. The OPTIMA RedTop battery is engineered for high-power cranking ability, even in challenging weather conditions, making it suitable for various automotive applications including cars, trucks, and SUVs. Its unique SpiralCell design ensures a consistent and powerful energy source.

OPTIMA 34/78 RedTop Battery

Image 1.1: OPTIMA 34/78 RedTop Battery, front view.

2. Émbaran Kasalametan

WARNING: Batteries contain sulfuric acid and produce explosive gases. Improper handling can cause severe injury or death.

  • Always wear appropriate personal protective equipment, including safety glasses and gloves, when handling batteries.
  • Ensure adequate ventilation when working with batteries to prevent the accumulation of explosive hydrogen gas.
  • Jauhkeun kembang api, seuneu, sareng bahan roko tina batréna.
  • Hindarkeun kontak sareng asam batré. Upami aya kontak, langsung bilas ku cai sareng milarian bantosan médis.
  • Ulah pondok-circuit terminal batré.
  • Jauhkeun batré tina jangkauan barudak.
  • Always disconnect the negative (black) terminal first and connect it last during installation or removal.

3. Fitur Produk

The OPTIMA 34/78 RedTop battery incorporates advanced technology for reliable performance:

  • SpiralCell Technology: Utilizes 99.99% pure lead in a unique spiral-wound cell design, delivering more power and outperforming conventional flat-plate batteries. This design also contributes to superior vibration resistance.
  • High Cranking Amps: Provides 800 Cold Cranking Amps (CCA) for optimal starting power, even in cold weather conditions.
  • Kapasitas cadangan: Offers a reserve capacity of 100 minutes, ensuring sustained performance.
  • Pangropéa-gratis: The sealed AGM (Absorbed Glass Mat) design eliminates the need for water additions and prevents acid spills, offering maximum convenience.
  • Résistansi Geter: Designed to be fifteen times more resistant to vibration compared to standard flooded batteries, enhancing durability.
  • Hirup leuwih panjang: Engineered for up to three times longer life than standard flooded batteries.
  • Faster Recharging: Capable of faster recharging, reducing downtime.
  • Pamasangan serbaguna: Completely non-spillable, allowing for mounting in various positions.
OPTIMA SpiralCell Technology Diagram

Image 3.1: Diagram illustrating OPTIMA's SpiralCell Technology with pure lead plates and absorbent glass-mat separators.

OPTIMA Battery benefits: 15x more vibration resistance, meets high electrical demands, 3x longer life

Image 3.2: Visual representation of key OPTIMA battery benefits.

4. Spésifikasi

SpésifikasiNilai
Voltage12-Volt
Tiis Cranking Amps (CCA)800 CCA
C20 Capacity50 H
Kapasitas cadangan100 menit
Ukuran (L x W x H)10.06" x 6.94" x 7.88" (254mm x 175mm x 200mm)
Beurat38.8 pon
Tipe TerminalDual SAE & GM Posts
Jumlah Sél6
Nomer modél34/78 (OEM Part Number: 8004-003)
OPTIMA 34/78 RedTop Battery front view kalayan terminal

Gambar 4.1: Hareupeun view of the OPTIMA 34/78 RedTop Battery, showing terminal configuration.

5. Setup jeung Instalasi

Proper installation is crucial for battery performance and safety. If you are unsure about any step, consult a qualified automotive technician.

5.1 Cék Pra-Pamasangan

  • Verify that the OPTIMA 34/78 RedTop battery is the correct size and type for your vehicle.
  • Inspect the battery for any signs of damage. Do not install a damaged battery.
  • Ensure your vehicle's ignition is off and all accessories are disconnected.

5.2 Removal of Old Battery

  1. Panggihan batréna kandaraan.
  2. Using an appropriate wrench, disconnect the negative (black, -) terminal cable first. Store it away from the battery.
  3. Next, disconnect the positive (red, +) terminal cable.
  4. Cabut sagala konci anu nahan batréamps atawa tali.
  5. Carefully lift and remove the old battery. Batteries are heavy; use proper lifting techniques or assistance.

5.3 Installation of New Battery

  1. Clean the battery tray and terminal clamps to ensure good electrical contact.
  2. Place the OPTIMA 34/78 RedTop battery into the battery tray, ensuring it is seated securely.
  3. Secure the battery with hold-down clamps atawa tali.
  4. Connect the positive (red, +) terminal cable first. Tighten securely.
  5. Connect the negative (black, -) terminal cable last. Tighten securely.
  6. Apply a thin layer of anti-corrosion grease to the terminals to prevent corrosion.
OPTIMA 34/78 RedTop Battery side view

Gambar 5.1: Sisi view of the OPTIMA 34/78 RedTop Battery, showing its compact design.

6. Parentah Operasi

The OPTIMA 34/78 RedTop battery is designed for starting applications, providing a powerful burst of energy to start your engine. Once installed, it operates as a standard automotive starting battery.

  • Ensure all electrical connections are tight and free of corrosion for optimal performance.
  • The battery's 800 CCA rating ensures reliable starting even in low temperatures.
  • The 100-minute reserve capacity provides a safety margin for vehicle electrical systems.
OPTIMA RedTop Battery in an outdoor setting

Image 6.1: OPTIMA RedTop Battery in a typical usage environment.

7. Pangropéa

The OPTIMA RedTop battery is a sealed, maintenance-free AGM battery, meaning it does not require water additions or electrolyte level checks.

  • Terminal Cleaning: Periodically inspect battery terminals for corrosion. If corrosion is present, disconnect the battery (negative first, then positive) and clean the terminals and cable clamps with a wire brush and a baking soda/water solution. Rinse with clean water and dry thoroughly before reconnecting.
  • Terminal Security: Ensure battery cables are always securely fastened to the terminals. Loose connections can lead to poor performance and potential damage.
  • Battery Top: Keep the top of the battery clean and dry to prevent current leakage.
  • Ngecas: If the vehicle is stored for extended periods or experiences frequent short trips, occasional charging with a compatible AGM battery charger is recommended to maintain optimal charge and extend battery life. Avoid overcharging.

8. Cara ngungkulan

If you experience issues with your OPTIMA 34/78 RedTop battery, consider the following:

8.1 Engine Cranks Slowly or Not at All

  • Pariksa sambungan: Ensure battery terminals and cable clamps are clean and tightly secured. Loose or corroded connections can impede current flow.
  • Ngeusi batre: The battery may be discharged. Use a voltmeter to check the battery voltage. A fully charged 12V battery should read approximately 12.6V or higher. If low, charge the battery using an appropriate AGM charger.
  • Alternator/Charging System: If the battery repeatedly discharges, have your vehicle's charging system (alternator, voltage regulator) inspected by a professional.

8.2 Lights Dim or Electrical Accessories Malfunction

  • This often indicates a low battery charge. Follow the steps for checking battery charge and charging as described above.
  • Inspect for any parasitic drains on the electrical system that might be discharging the battery when the vehicle is off.

For persistent issues, consult a professional automotive technician or OPTIMA customer support.

9. Garansi jeung Rojongan

For detailed warranty information regarding your OPTIMA 34/78 RedTop battery, please refer to the official warranty documentation provided with your purchase or visit the official OPTIMA websitus. Sarat jeung kaayaan jaminan bisa rupa-rupa.

For technical assistance, product inquiries, or support, please contact OPTIMA customer service through their official channels. You can find more information and contact details on the OPTIMA Brand Store.

Dokumén Patali - 34/78

Praview OPTIMA D200+ 12V Performance Maintainer User Guide
Comprehensive user guide for the OPTIMA D200+ 12V Performance Maintainer and 2 Amp Hypercore Lithium Charger. Covers features, safety, operation, installation, troubleshooting, and technical specifications for 12V batteries including Lithium LiFePO4, AGM, and Flooded Lead-Acid types.
Praview OPTIMA D200+ 12V Performance Maintainer User Guide
Comprehensive user guide for the OPTIMA D200+ 12V Performance Maintainer and 2 Amp HyperCore Lithium Charger. Covers safety instructions, product features, operation, installation, troubleshooting, and technical specifications.
Praview Optima Fire Alarm Control Panel Installation Manual
Comprehensive installation manual for the Optima Fire Alarm Control Panel (FACP), detailing wiring, configuration, mounting, and troubleshooting. Complies with EN54 and BS:EN 5839 standards.
Praview Manual Pamaké OPTIMA D26AT: Panyimpenan sareng Panungtun Pembuangan
Pituduh singket ngeunaan nyimpen sareng miceun alat anu tiasa dicas deui OPTIMA D26AT, nyertakeun suhu, kalembaban, ngecas, sareng patuh diréktif WEEE.
Praview Optima Otomatis Sprinkler Timer PRT-4 / PRT-6 Manual Pamilik
Manual Pamilik pikeun Optima Otomatis Sprinkler Timer PRT-4 / PRT-6, detailing instalasi, programming, jeung perawatan.
Praview Optima PRT-4/PRT-6 Automatic Sprinkler Timer User Manual
This user manual provides detailed instructions for installing, programming, and maintaining the Optima PRT-4 and PRT-6 Automatic Sprinkler Timers. Learn how to set watering schedules, durations, and troubleshoot common issues.