Altronix 6062

Buku Panduan Pangguna Timer Digital Altronix 6062

Modél: 6062

1. Produk Langkungview

The Altronix Digital Timer 6062 is a versatile multi-function timer designed for various applications requiring precise timing control. It supports both 12VDC and 24VDC operation and features SPDT (Single Pole Double Throw) contacts rated at 8 amps / 115VAC. The timing range is adjustable from 1 second to 60 minutes, offering flexibility for different operational needs. Additionally, it provides a one-second momentary relay activation at the end of its timing cycle.

Altronix Digital Timer 6062 circuit board with components and wiring terminals.

This image displays the Altronix Digital Timer 6062 circuit board. Key components visible include a blue PCB, a white rotary potentiometer for timing adjustment, a red DIP switch block, a black relay, and screw terminals for wiring connections. Various resistors, capacitors, and jumper points (J1, J2, J3) are also present, along with text indicating 'MADE IN U.S.A.' and 'RoHS' compliance.

2. Setélan

2.1. Syarat Daya

The Altronix 6062 timer operates on either 12VDC or 24VDC. Ensure that the power supply matches the selected voltage setting on the device. Incorrect voltage tiasa ngaruksak unit.

2.2. Panyambungan

Connect the power supply and controlled device to the screw terminals located on the board. The terminals are typically labeled for input power (e.g., + and -) and relay contacts (e.g., Normally Open (NO), Normally Closed (NC), Common (C)). Refer to the wiring diagram provided with your specific application for correct connections.

2.3. Setélan Jumper

The timer features several jumper points that modify its operational behavior:

  • J1 (Repeat): Cutting jumper J1 enables the repeat function, allowing the timing cycle to re-trigger under specific conditions.
  • J2 (Delayed Pulse): Cutting jumper J2 activates a delayed pulse output, which provides a momentary relay activation after a set delay.
  • J3 (Reset on Power-Up): Cutting jumper J3 configures the timer to reset its cycle upon power-up, ensuring a consistent starting state.

3. Parentah Operasi

3.1. Timing Adjustment

The timing duration is adjusted using the white rotary potentiometer on the board. This knob allows for fine-tuning the delay from 1 to 60 units. The unit of time (seconds or minutes) is selected via the DIP switch settings.

3.2. DIP Pindah Konfigurasi

The red DIP switch block controls various operational parameters. Each switch corresponds to a specific function:

  • Switch 1 (RELAY CONTROL): Controls the relay's behavior or mode of operation.
  • Switch 2 (SEC/MIN): Toggles the timing unit between seconds and minutes for the rotary adjustment.
  • Switch 3 (12V/24V): Selects the operating voltage for the timer (12VDC or 24VDC). Ensure this matches your power supply.
  • Switch 4 (TRIG CONTROL): Manages the trigger input behavior, determining how the timer initiates its cycle.

Refer to the specific application notes or detailed wiring diagrams for the exact ON/OFF positions for each switch to achieve desired functionality.

3.3. Relay Operation

The timer features SPDT contacts, meaning it has a Common (C), Normally Open (NO), and Normally Closed (NC) contact. When the timer activates, the relay switches state, connecting the Common terminal to either the NO or NC terminal, depending on the timer's state and configuration. These contacts are rated for 8 amps dina 115VAC.

4. Pangropéa

The Altronix Digital Timer 6062 is designed for reliable operation with minimal maintenance. Periodically inspect the unit for any signs of physical damage, loose connections, or excessive dust accumulation. Ensure all wiring connections are secure. Clean the board gently with a dry, soft brush if necessary. Do not use liquid cleaners or solvents.

5. Cara ngungkulan

If the timer is not functioning as expected, consider the following troubleshooting steps:

  • Henteu aya kakuatan: Pariksa yén vol benertage (12VDC or 24VDC) is supplied to the timer and that the power connections are secure. Check the 12V/24V DIP switch setting.
  • Timing salah: Ensure the rotary knob is set to the desired value and that the SEC/MIN DIP switch is in the correct position.
  • Relay Teu Aktipkeun: Check the relay control DIP switch setting. Verify that the load connected to the relay contacts is within the specified 8 amp / 115VAC rating.
  • Paripolah anu teu disangka-sangka: Review all jumper settings (J1, J2, J3) and DIP switch configurations to ensure they match your intended operation.

If issues persist, consult a qualified technician or contact customer support.

6. Spésifikasi

FiturSpésifikasi
Nomer modél6062
Operasi Voltage12VDC or 24VDC (selectable)
Kontak RelaySPDT (Lemparan Ganda Tiang Tunggal)
Kontak Rating8 Amps @ 115VAC
Rentang Timing1 second to 60 minutes (adjustable)
Ukuran (L x W x H)4.75" x 2.25" x 1.5" (kira-kira)
Beurat0.18 ons (kira-kira)
BahanMetal (components), Blue (PCB)
Jumlah Setélan6 (DIP switch configurations)

7. Garansi jeung Rojongan

7.1. Émbaran jaminan

Warranty terms for the Altronix Digital Timer 6062 are typically provided by the manufacturer at the time of purchase. Please refer to the documentation included with your product or visit the official Altronix websitus kanggo inpormasi garansi lengkep.

7.2. Rojongan Palanggan

For technical assistance, troubleshooting beyond the scope of this manual, or inquiries regarding product functionality, please contact Altronix customer support. Contact details can usually be found on the manufacturer's websitus atanapi bungkusan produk.

Dokumén Patali - 6062

Praview Altronix 6062 Multi-purpose Timer: Installation and Application Guide
Detailed guide for the Altronix 6062 Multi-purpose Timer, covering specifications, installation instructions, dip switch and jumper settings, terminal identification, and typical applications for access control, security systems, and automation.
Praview Altronix Tempo2 Installation Guide: One-Shot/Test Timer
Comprehensive installation guide for the Altronix Tempo2 Digital Test / Trigger Mode Timer, covering overview, specifications, one-shot features, test timer programming, trigger mode programming, and typical applications.
Praview Altronix DL1 Door Control Timer: Spésifikasi jeung Guide Instalasi
Spésifikasi lengkep sareng petunjuk pamasangan pikeun Altronix DL1 Door Control Timer, nampilkeun waktos anu tiasa diatur, kaluaran relay, sareng vol serbaguna.tage operasi.
Praview Altronix 6030 Multi-Purpose Timer: Specifications and Installation Guide
Detailed specifications, features, and installation instructions for the Altronix 6030 Multi-Purpose Timer, a versatile programmable timer for various applications.
Praview Altronix DL3 Door Control Timer: Spésifikasi jeung Guide Instalasi
Spésifikasi lengkep sareng pitunjuk pamasangan pikeun Altronix DL3 Door Control Timer, alat 12-24V AC/DC pikeun sistem kontrol aksés.
Praview Altronix Trove2 / Kit raksa jeung ngahiji Outputs Guide Instalasi
Pituduh pamasangan pikeun kit Altronix Trove2/Mercury, ngajéntrékeun rupa-rupa model kaluaran gabungan, pilihan konfigurasi, jeung parentah assembly pikeun sistem kontrol aksés. Kaasup leuwihview, bagan konfigurasi, léngkah-léngkah pamasangan, sareng dimensi enclosure.