Ademco 5816

Ademco Honeywell 5816 Wireless Transmitter User Manual

Modél: 5816

1. Bubuka

The Ademco Honeywell 5816 is a wireless two-zone transmitter designed for integration with compatible security systems. This device provides reliable security monitoring for doors and windows by detecting their open or closed status. It features a built-in magnetic reed switch and also supports an external wired closed-circuit contact loop, offering versatile installation options.

2. Fitur Produk

3. Eusi Paket

Pastikeun sadaya barang tos aya sateuacan ngamimitian pamasangan:

4. Setup jeung Instalasi

Proper installation ensures optimal performance and reliable security. Refer to your security system's control panel manual for specific programming instructions.

4.1. Pamasangan batré

  1. Buka pemancar casing by gently pressing the tab on the bottom and lifting the cover.
  2. Insert the supplied CR123 Lithium Ion battery, observing the correct polarity (+/-).
  3. Tutup panutupna aman.

4.2. Mounting the Transmitter and Magnet

The transmitter and magnet should be mounted on the door/window frame and the moving part (door/window) respectively, ensuring they are aligned and within approximately 1 inch (2.5 cm) of each other when the door/window is closed.

Ademco Honeywell 5816 Wireless Transmitter front view

Gambar 1: Hareupeun view of the Ademco Honeywell 5816 Wireless Transmitter. This image displays the compact, rectangular design of the transmitter unit, typically mounted on a door or window frame.

  1. Choose a mounting location on the door or window frame where the transmitter will not interfere with operation and is protected from damage.
  2. Mount the transmitter using the provided screws or double-sided adhesive tape. Ensure the mounting plate is secured first, then attach the transmitter.
  3. Mount the magnet on the corresponding moving part (door or window) directly opposite the reed switch marking on the transmitter. Use the magnet spacer if necessary to achieve proper alignment and gap.
  4. Test the alignment by opening and closing the door/window. The security system should register the change in status.

4.3. Wiring an External Contact (Optional)

The 5816 transmitter supports an external wired closed-circuit contact loop (Loop 4). This allows for monitoring of a separate device or a different type of contact.

  1. Connect the external contact wires to the designated terminals inside the transmitter.
  2. Ensure connections are secure and properly insulated.
  3. Program the external loop (Loop 4) into your security system's control panel as per its instructions.

5. Parentah Operasi

The Ademco Honeywell 5816 operates by wirelessly transmitting signals to your security system's control panel when a change in its contact status occurs.

The control panel interprets these signals and responds according to its programming (e.g., sounding an alarm, sending notifications).

6. Pangropéa

6.1. Ngagantian batré

The 5816 transmitter uses one CR123 Lithium Ion battery, which typically has a life of approximately 5 years. Your security system will usually provide a low battery warning when replacement is needed.

  1. Disarm your security system to prevent false alarms during battery replacement.
  2. Gently press the tab on the bottom of the transmitter and remove the front cover. This action may trigger a tamper alert on your control panel, which can be cleared after replacement.
  3. Cabut batré CR123 anu lami kalayan ati-ati.
  4. Insert a new CR123 Lithium Ion battery, ensuring correct polarity.
  5. Replace the front cover, ensuring it snaps securely into place.
  6. Verify that the transmitter is communicating with the control panel by testing the door/window.

6.2. beberesih

Clean the exterior of the transmitter and magnet periodically with a soft, dry cloth. Avoid using abrasive cleaners or solvents, as these can damage the casing.

7. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Transmitter not responding / No signalDead or low battery; Magnet misalignment; Out of range; Programming issue.Replace battery; Adjust magnet position (within 1 inch); Verify transmitter is within range of control panel; Check control panel programming.
False alarms / Intermittent signalsLoose wiring (for external contact); Magnet too far from transmitter; Environmental interference.Check external contact wiring; Realign magnet; Ensure no large metal objects are interfering; Consult control panel manual.
Peringatan batré lemah tetep aya saatos digantiIncorrect battery type; Battery not fully seated; System not reset.Ensure correct CR123 Lithium Ion battery is used; Re-seat battery; Refer to control panel manual for clearing low battery signals.

If issues persist, consult your security system's control panel manual or contact a qualified security technician.

8. Spésifikasi

Nomer modél5816
Ukuran (H x W x D)3-1/16'' x 1-9/16'' x 1-3/16'' (approx. 7.78 cm x 3.97 cm x 3.02 cm)
Beurat12.6 ons (kira-kira 357 gram)
Sumber DayaBatré Powered
Jenis Batré1 x CR123 Lithium Ion battery
Nominal Voltage3 Volt (DC)
Rata Kahirupan BatréKurang leuwih 5 taun
Fitur hususMagnetic contact, Wireless, Tampdeteksi er
Alat nu cocogHoneywell Home 5800 Series devices, 5899 magnet
Range nirkabelUp to 200 feet (approx. 61 meters) indoors; over 1 mile (approx. 1.6 km) outdoors (line of sight)
Tingkat Résistansi CaiHenteu Tahan Cai

9. Garansi jeung Rojongan

Specific warranty information for the Ademco Honeywell 5816 Wireless Transmitter is typically provided at the point of purchase or through your security system installer. Please retain your proof of purchase for warranty claims.

For technical support, programming assistance, or troubleshooting beyond the scope of this manual, please contact your security system provider or a certified Honeywell/Ademco dealer.

10. Sumberdaya tambahan

For further details on integrating this transmitter with your specific security system, refer to the installation and programming guides for your Honeywell or Ademco control panel.

No official product videos are available for inclusion in this manual.

Dokumén Patali - 5816

Praview ADEMCO 5808 Photoelectronic Smoke/Heat Detector Installation Instructions
Comprehensive installation, testing, maintenance, and safety guidelines for the ADEMCO 5808 Photoelectronic Smoke/Heat Detector with built-in wireless transmitter, designed for QED control panels. Includes specifications, limitations, and warranty information.
Praview Ademco No. 1022-12 Alarm Processing Center Installation Manual
Comprehensive installation, wiring, and testing guide for the ADEMCO No. 1022-12 Alarm Processing Center, a U.L. Listed security system control panel featuring multiple zones, entry/exit delays, and standby power.
Praview ADEMCO No. 1022 Alarm Processing Center Installation Manual
Comprehensive installation, wiring, and testing guide for the ADEMCO No. 1022 Alarm Processing Center, a U.L. Listed Grade A local control unit for burglary and holdup alarm systems.
Praview ADEMCO VISTA-20P/PS sareng VISTA-15P Series Security Systems Installation and Set-Up Guide
Pamasangan lengkep sareng pituduh set-up pikeun ADEMCO VISTA-20P/PS sareng sistem kaamanan séri VISTA-15P, ngawengku fitur, wiring, program, sareng pedoman operasional.
Praview ADEMCO 652MK Recessed Mounting Kit Installation Instructions
Detailed installation guide for the ADEMCO 652MK Recessed Mounting Kit, designed for use with ADEMCO Passive Infrared Motion Detectors like models 652, 653, and 1852.
Praview Pituduh Pangguna Sistem Kaamanan ADEMCO LYNXR-EN - Fitur sareng Operasi
Pituduh pangguna anu lengkep pikeun sistem kaamanan ADEMCO LYNXR-EN, anu ngajelaskeun fitur, operasi, pamasangan, sareng pangropéa pikeun panyalindungan maling, kahuruan, sareng darurat.