1. Bubuka
Manual ieu nyayogikeun inpormasi penting pikeun pamasangan, operasi, sareng pangropéa Leviton 55050 50 anu aman sareng leres. Amp, 125/250 Volt, NEMA 14-50R Surface Mounting Receptacle. This industrial-grade receptacle is designed for heavy-duty applications requiring a 50 Amp, 125/250 Volt connection. Please read all instructions carefully before proceeding with installation or use.
2. Émbaran Kasalametan
PERHATOSAN: Risk of electric shock or fire. Improper installation can result in serious injury or death. All electrical work should be performed by a qualified electrician in accordance with all national and local electrical codes.
- Salawasna pegatkeun sambungan kakuatan dina circuit breaker atawa kotak sekering saméméh masang atawa ngalayanan alat ieu.
- Ensure the wiring used is appropriate for the 50 Amp, 125/250 Volt rating of this receptacle.
- Pastikeun sadaya sambungan aman sareng insulated leres.
- This device is designed for surface mounting. Do not attempt to recess it into a wall unless specifically designed for such an application.
- Keep children away from electrical outlets.
3. Fitur Produk
- Durable thermoplastic construction for long-lasting performance.
- Heavy-gauge, double-wire copper alloy contacts ensure reliable electrical connections.
- Terminals are clearly marked for easy identification and fast wiring.
- Designed for surface mounting, eliminating the need for in-wall cutting.
- Accepts up to No. 4 AWG conductors for robust power delivery.
- Ngawengku sakabéh hardware ningkatna perlu.
- Compatible with wallplates featuring a 2.15-inch diameter center hole.
4. Spésifikasi
| Atribut | Spésifikasi |
|---|---|
| merek | Leviton |
| Nomer modél | 55050 |
| Ampumur | 50 Amps |
| Voltage | 125/250 volt |
| Konfigurasi NEMA | 14-50R |
| Tiang / Kawat | 3-Kutub, 4-Kawat |
| Tipe Pamasangan | Pamasangan permukaan |
| Bahan | Thermoplastic |
| Warna | Hideung |
| Dimensi produk | 4.82 "L x 2.68" W |
| Item Beurat | 8 ons |
| Sertifikasi | CSA, NOM, UL |
5. Setup jeung Instalasi
Sateuacan anjeun ngamimitian: Ensure the main power supply to the circuit is turned OFF at the service panel. Use a voltagalat panguji e pikeun mastikeun daya pareum sateuacan noel kabel naon waé.
- Nyiapkeun Surface Mounting: Select a suitable, flat surface for mounting. Ensure there is adequate space for the receptacle and any associated conduit or wiring.
- Mount the Receptacle Housing: Use the provided mounting hardware to securely attach the receptacle's outer housing to the chosen surface. Ensure it is level and firmly affixed.
- Sambungan Kawat:
- Strip approximately 3/4 inch of insulation from each wire (Line 1, Line 2, Neutral, Ground).
- Identify the terminals on the receptacle. They are typically marked:
- X jeung Y: Hot (Line 1 and Line 2)
- W: nétral
- G: taneuh
- Insert each stripped wire into its corresponding terminal. The side-wired design allows for easy insertion.
- Tighten the terminal screws firmly to ensure a secure connection. Verify that no bare wire is exposed outside the terminal.
- Secure the Receptacle Insert: Once wiring is complete, carefully place the receptacle insert into the housing and secure it with the provided screws.
- Mulangkeun Daya: After ensuring all connections are correct and secure, restore power at the service panel.

6. Parentah Operasi
The Leviton 55050 NEMA 14-50R receptacle is designed for straightforward operation with compatible 50 Amp, 125/250 Volt devices. Once properly installed and powered:
- Ensure your appliance or device has a NEMA 14-50P plug.
- Align the prongs of the plug with the corresponding slots on the receptacle.
- Insert the plug firmly into the receptacle until it is fully seated.
- To disconnect, grasp the plug body and pull it straight out from the receptacle. Do not pull by the cord.
7. Pangropéa
Regular maintenance helps ensure the longevity and safe operation of your receptacle.
- beberesih: Periodically wipe the exterior of the receptacle with a clean, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
- Pamariksaan: Annually inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, disconnect power and have the unit inspected and replaced by a qualified electrician.
- Pariksa sambungan: If the receptacle is subject to frequent plugging/unplugging or heavy use, periodically check the terminal screws for tightness (with power OFF).
8. Cara ngungkulan
If you experience issues with your Leviton 55050 receptacle, consider the following:
- Henteu aya kakuatan: Check the circuit breaker in your service panel. A tripped breaker will cut power to the receptacle. Reset the breaker if necessary.
- Sambungan leupas: If the plug feels loose in the receptacle, or if there is intermittent power, disconnect power and have a qualified electrician inspect the wiring connections for tightness.
- Overheating: If the receptacle or plug feels hot to the touch, immediately disconnect the appliance and turn off power to the circuit. This could indicate an overload or a faulty connection. Consult a qualified electrician.
- Ruksakna Fisik: Any visible damage to the receptacle (cracks, burns, etc.) requires immediate power disconnection and replacement by a qualified electrician.
For issues not resolved by these steps, or if you are unsure about any electrical procedure, always consult a qualified electrician.
9. Garansi jeung Rojongan
Garansi: This Leviton 55050 receptacle is covered by a 10-Taun jaminan kawates. This warranty covers defects in materials and workmanship under normal use and service. For specific terms and conditions, please refer to the warranty documentation included with your purchase or visit the official Leviton websitus.
Rojongan Palanggan: For technical assistance, warranty claims, or further information regarding your Leviton product, please contact Leviton customer support through their official websitus atanapi inpormasi kontak anu disayogikeun dina bungkusan produk anjeun.