1. Bubuka
The Elitech LMG-10/LMG-10W Digital Manifold Gauge Set is a high-precision instrument designed for accurate measurement of real-time temperature and pressure values in air-conditioning and refrigeration systems. This smart manifold offers dual-channel pressure and temperature measurement, built-in refrigerant libraries, and advanced features like superheat and subcooling calculation, making HVAC/R work more efficient and reliable. The LMG-10W model further enhances functionality with wireless connectivity and data logging capabilities.
2. Émbaran Kasalametan
Mangga baca sareng pahami sadaya pitunjuk kaamanan sateuacan ngoperasikeun alat ieu. Upami henteu nuturkeun pitunjuk ieu tiasa nyababkeun cilaka atanapi karusakan kana alat.
- This product is a high-precision device. Avoid violent impacts or dropping the unit.
- Ulah neuleumkeun alat dina cai atawa kakeunaan ka beueus kaleuleuwihan.
- Ensure the device is used within its specified operating range.
- Always wear appropriate personal protective equipment (PPE) when working with refrigeration systems.
- Disconnect the device from the refrigeration system before performing any maintenance or cleaning.
- Only qualified personnel should perform service or repairs on refrigeration systems.
3. Eusi Paket
Pastikeun yén sadaya item aya dina pakét anjeun:
- Digital Manifold Gauge (LMG-10 or LMG-10W)
- Blow Molding Box (for storage)
- Wired Temperature Clamp (Hijian 2)
- Three-color Tubes (3 units, included with LMG-10W model)
4. Komponén produk
The Elitech Digital Manifold Gauge features a clear digital display and multiple connection ports for comprehensive system analysis. Refer to the diagram below for component identification:

This image illustrates the main components and connection points of the digital manifold gauge. It highlights the 'Temperature on the low pressure side' and 'High voltage side temperature' inputs, 'Low side pressure' and 'High side pressure' ports, and the 'Filling/recycling/vacuuming' port.
- Digital tampilan: Shows real-time pressure, temperature, and other operational data.
- Tombol kontrol: For mode selection, navigation, and data input.
- Low Side Pressure Port: Typically blue, for connecting to the low-pressure side of the refrigeration system.
- High Side Pressure Port: Typically red, for connecting to the high-pressure side of the refrigeration system.
- Filling/Recycling/Vacuuming Port: Typically yellow, for connecting to a refrigerant tank, recovery unit, or vacuum pump.
- Temperature Sensor Inputs: For connecting the wired temperature clamps to measure pipe temperatures.
5. Spésifikasi
The following table outlines the key specifications for the LMG-10 and LMG-10W models:

This table provides a detailed comparison of features and specifications across different Elitech digital manifold gauge models, including LMG-10 and LMG-10W.
| Fitur | LMG-10 | LMG-10W |
|---|---|---|
| Kategori | Digital table | Digital table |
| Akurasi tekanan | Precision tinggi | Precision tinggi |
| Sambungan Pipa | Dual pressure measurement + 1 way vacuum/filling | Dual pressure measurement + 1 way vacuum/filling |
| Modeu Pangukuran Suhu | Saluran Dual | Saluran Dual |
| Saturation Temperature Check | Built-in 88 types | Built-in 88 types (connects to 140+ types via app) |
| Overheating/Coldness Calculation | Automatic calculation and display | Automatic calculation and display |
| Pintonan layar | tampilan digital | tampilan digital |
| Bluetooth Networking/App Upgrade | No | Sumuhun |
| Pressure Holding Interface | Sumuhun | Sumuhun |
| Vacuum Interface | Sumuhun | Sumuhun |
| Data Logging | No | Sumuhun |
| Real-time Refrigerant Updates | No | Sumuhun |
| Multilingual Switching | No | No |
| Bungkusan | Blow molding box | Blow molding box |
| Asesoris baku | Suhu kabel clamp*2 | Suhu kabel clamp*2, three-color tube*3 |
| Ukuran | 180 * 180 * 60 mm | 180 * 180 * 60 mm |
| Beurat | 0.9 kg | 0.9 kg |
6. Setup sareng Sambungan Awal
Before operating the digital manifold gauge, ensure all connections are secure and appropriate for the refrigeration system you are working on.
- Daya Hurung: Pencét tombol daya pikeun ngaktipkeun alat.
- Sambungkeun hoses:
- Connect the blue hose to the low side pressure port on the manifold and to the low-pressure service port of the refrigeration system.
- Connect the red hose to the high side pressure port on the manifold and to the high-pressure service port of the refrigeration system.
- Connect the yellow hose to the filling/recycling/vacuuming port on the manifold. This hose will be connected to a vacuum pump, refrigerant tank, or recovery unit as needed.
- Attach Temperature Clamps: Securely attach the wired temperature clamps to the refrigerant lines (e.g., suction line for low side temperature, liquid line for high side temperature) to measure pipe temperatures accurately. Plug the clamps into the designated temperature sensor inputs on the manifold.
- (LMG-10W Only) Bluetooth Connection: If using the LMG-10W model, ensure Bluetooth is enabled on your mobile device and pair it with the manifold gauge via the Elitech app for extended refrigerant libraries and data logging.
7. Operasi
The Elitech Digital Manifold Gauge offers various modes and functions to assist with HVAC/R diagnostics and servicing.
7.1 Dual Channel Pressure and Temperature Measurement
The device accurately measures and displays real-time pressure and temperature values from both the high and low sides of the refrigeration system. This data is crucial for assessing the system's operating status.

This image shows the manifold gauge actively measuring and displaying temperature and pressure on both the high and low sides of a refrigeration system.
7.2 Refrigerant Type Selection and Saturation Temperature
The manifold gauge has 88 refrigerant types built-in. The LMG-10W model, when connected to the app, can access over 140 refrigerant types. This allows for quick model switching and real-time display of the corresponding saturation temperature.

The display shows various refrigerant types (e.g., R11, R22, R113, R114, R125, R21) and the saturation temperature, indicating the device's universal compatibility.
7.3 Superheat and Subcooling Measurement
The device automatically calculates and displays superheat and subcooling values. These measurements are critical for diagnosing the operating status of air conditioning and refrigeration systems and ensuring optimal efficiency and equipment security.

This image emphasizes the importance of superheat and subcooling measurements for system diagnostics.
7.4 Modeu operasi
The manifold gauge supports multiple operating modes, which can be switched as needed:

This image showcases the device's smart features, including automatic superheat/subcooling, high-precision detection, temperature compensation, support for 88 refrigerants, Bluetooth networking (LMG-10W), and three switchable modes.
7.5 Pressure Holding and Leakage Testing Mode
This mode allows for scientific determination of the system's operating status by testing for pressure leaks.
- Daya Hurung: Ensure the equipment is powered on.
- Sistim Sambungkeun: Connect the manifold to the inline refrigeration system.
- Buka klep: Ensure the black valve on the manifold is open.
- Lebetkeun Mode: Press the designated key combination (refer to your device's specific button layout) to enter the "hold" pressure holding mode.
- Mimitian Test: Press the start/stop button to begin holding the pressure. The display will show the timer, initial pressure, current pressure, and pressure difference value.
- Réngsé Tés: Press the start/stop button again to end the test.

This image shows the manifold gauge's display during a pressure holding test, indicating the timer, initial pressure, current pressure, and pressure difference value.
7.6 Produk Leuwihview Video
For a visual demonstration of the product and its features, please watch the following video:
video ieu nyadiakeun leuwih umumview of the Elitech Digital Manifold Gauge, showcasing its design and some operational aspects.
8. Pangropéa
Proper maintenance ensures the longevity and accuracy of your digital manifold gauge.
- beberesih: Ngusap alat ku kaén anu lemes sareng garing. Ulah make cleaners abrasive atawa pangleyur.
- Panyimpenan: Store the manifold gauge in its blow molding box in a dry, cool place away from direct sunlight and extreme temperatures.
- Perawatan selang: Inspect hoses regularly for cracks, leaks, or damage. Replace damaged hoses immediately.
- Batré: If the device uses replaceable batteries, ensure they are changed when indicated by the low battery warning. Remove batteries if storing the device for an extended period.
9. Cara ngungkulan
If you encounter issues with your Elitech Digital Manifold Gauge, try the following steps:
- Henteu aya kakuatan: Check battery levels or ensure the device is properly charged.
- Bacaan teu akurat: Verify that all connections (hoses, temperature clamps) are secure and free from leaks. Ensure the correct refrigerant type is selected.
- Bluetooth Connectivity Issues (LMG-10W): Ensure Bluetooth is enabled on both the manifold and your mobile device. Restart both devices and try pairing again. Check if the Elitech app is up to date.
- Kasalahan tampilan: Coba balikan deui alat. Upami masalahna tetep, hubungi dukungan palanggan.
10. Tips pamaké
- Always perform a vacuum test before charging a system to ensure no leaks are present.
- For precise temperature measurements, ensure the temperature clamps are securely attached to clean, bare metal sections of the refrigerant lines.
- Utilize the app (for LMG-10W) to access the most up-to-date refrigerant libraries and advanced data analysis features.
- Regularly calibrate your gauge set according to manufacturer recommendations to maintain accuracy.
11. Garansi jeung Rojongan
For warranty information, technical support, or service inquiries, please refer to the official Elitech websitus atanapi ngahubungan dealer otorisasi Anjeun. Simpen resi pameseran anjeun salaku bukti pameseran pikeun klaim garansi.