Bubuka
This manual provides detailed instructions for the setup, operation, and specifications of the XH-M601, XH-M602, XH-M603, and XH-M604 Battery Charging Control Modules. These modules are designed to manage battery charging processes, ensuring optimal performance and longevity for various electrical equipment and tools.
spésifikasi
Below are the detailed specifications for each model:
1. XH-M603 Charging Control Module
| Fitur | Spésifikasi |
|---|---|
| Modél | XH-M603 |
| Masukan Voltage | DC 10-30V |
| Témbongkeun Akurasi | 0.1V |
| Kontrol Akurasi | 0.1V |
| Tipe Kaluaran | Kaluaran langsung |
| Voltage Toleransi | +/- 0.1V |
| Aplikasi | batré 12-24V |
| Ukuran | 82 * 58 * 18mm |

Figure 1: XH-M603 Charging Control Module
2. XH-M604 Battery Charger Control Module
| Fitur | Spésifikasi |
|---|---|
| Modél | XH-M604 |
| Masukan Voltage | DC 6-60V (maximum 80V) |
| Témbongkeun Akurasi | 0.1V |
| Kontrol Akurasi | 0.1V |
| Tipe Kaluaran | Kaluaran langsung |
| Voltage Toleransi | +/- 0.1V |
| Aplikasi | batré 6-60V |
| Ukuran | 81 * 54 * 18mm |

Figure 2: XH-M604 Battery Charger Control Module
3. XH-M602 Control Battery Charging Control Module
| Fitur | Spésifikasi |
|---|---|
| Modél | XH-M602 |
| Masukan Voltage | AC 220V |
| Témbongkeun Akurasi | 0.1V |
| Kontrol Akurasi | 0.1V |
| Tipe Kaluaran | Switch kaluaran |
| Voltage Toleransi | +/- 0.1V |
| Aplikasi | 3.7-120V lithium battery or battery |
| Ukuran | 86 * 58 * 24mm |

Figure 3: XH-M602 Control Battery Charging Control Module
4. XH-M601 Battery Charging Control Board
| Fitur | Spésifikasi |
|---|---|
| Modél | XH-M601 |
| Power Supply Voltage | 13.8-14.8V |
| Relay Working Voltage | 12.4V |
| Relay Disconnection Voltage | 14.8V |
| Voltage Toleransi | +/- 0.1V |
| Voltage Detéksi | Voltmeter DC |
| Mode ngecas | batré 12V |
| Potentiometer adjustment | RP1, RP2 |
| Ukuran | 50 * 32 * 18mm |

Figure 4: XH-M601 Battery Charging Control Board
Setelan sareng Kabel
Proper wiring is crucial for the safe and correct operation of these modules. Always ensure power is disconnected before making any wiring changes. Refer to the diagrams below for typical connection scenarios:

Figure 5: Comprehensive Wiring Diagrams for XH-M601, XH-M602, XH-M603, and XH-M604 modules. Includes connections for AC chargers, DC power supplies, and alternators.

Figure 6: Detailed wiring for XH-M601, showing connection to a 12V battery and a 220V charger with a voltmeter display.

Figure 7: Wiring for XH-M604, illustrating connection to an alternator and a 12-24V battery.

Figure 8: Wiring for XH-M602, showing connection to a 220V AC input and a 6-120V battery.

Figure 9: XH-M602 module in a practical setup, connected to a battery.
Pedoman Wiring Umum:
- Sambungkeun input voltage to the designated VIN terminals.
- Connect the battery to the BAT+ and BAT- terminals.
- For models with AC input (e.g., XH-M602), ensure correct L and N connections.
- Always observe polarity (+/-) when connecting DC components.
- Use appropriate gauge wires for the expected current to prevent overheating.
Operasi
These modules feature user-friendly controls for setting charging parameters.
Setélan Voltage Parameters (for models with digital display and buttons):
- Set Starting Voltage:
- Dina volume normaltage display state, press the "Start" button (or equivalent) to view the current start charging voltage.
- Long press the "Start" button for approximately 3 seconds until the digital display flashes.
- Use the "Start" and "Stop" buttons to adjust the desired starting charge voltagnilai e.
- Set Stop Voltage:
- Dina volume normaltage display state, press the "Stop" button (or equivalent) to view the current stopping charge voltage.
- Long press the "Stop" button for approximately 3 seconds until the digital display flashes.
- Use the "Start" and "Stop" buttons to adjust the desired stopping charge voltagnilai e.
- Pabrik Reset:
- While the module is powered on, simultaneously press the "Start" and "Stop" buttons.
- The digital display will show "888", indicating that the settings have been reset to factory defaults.
Potentiometer Adjustment (for models like XH-M601):
For models equipped with potentiometers (RP1, RP2), these can be used for fine-tuning voltage setélan:
- RP1: Adjusts the storage battery's start charging voltage. Turning clockwise increases the voltage, counter-clockwise decreases it.
- RP2: Adjusts the storage battery's disconnect charging voltage. Turning clockwise increases the voltage, counter-clockwise decreases it.
Pangropéa
These battery charging control modules are designed for reliable operation with minimal maintenance. To ensure optimal performance and longevity:
- Jaga modul tetep bersih sareng bébas tina lebu sareng kokotor.
- Ensure proper ventilation to prevent overheating, especially during prolonged operation.
- Regularly check all wiring connections for tightness and signs of corrosion.
- Ulah nepi ka modul ieu kakeunaan kalembaban anu kaleuleuwihi atanapi suhu anu ekstrim.
- Do not attempt to repair the module if you are not qualified. Contact a professional for assistance.
Pamérésan masalah
If you encounter issues with your battery charging control module, consider the following common troubleshooting steps:
- Modul teu hurung: Pariksa input voltage connections and ensure power supply is within the specified range for your model.
- Batré teu ngecas: Verify all battery connections, charger connections, and ensure the start voltage setting is below the current battery voltage.
- Battery overcharging: Check the stop voltage setting. Ensure it is set correctly for your battery type.
- Teu akurat voltage tampilan: Confirm stable input power. If issues persist, a factory reset might help.
- Module not switching: Ensure the relay is functioning. Check if the set voltages are being met.
If problems persist after basic troubleshooting, consult the wiring diagrams again or seek professional assistance.
Tip pamaké
- Always double-check wiring polarity before applying power to prevent damage to the module or battery.
- Nalika netepkeun voltage thresholds, allow for a small hysteresis (difference between start and stop voltages) to prevent rapid cycling of the relay.
- For critical applications, consider adding external fuses for additional protection.
Garansi sareng Rojongan
For any technical support or warranty-related inquiries, please contact the seller or manufacturer directly. Keep your purchase records handy for faster service.
Video Demonstrasi
Watch this video for a visual guide on the modules and their various wiring configurations.
Video: Leuwihview and Wiring Examples for XH-M60x Series Modules.