HUAWEI EPW3000-12A-X Server Power Supply Instruction Manual

Model: EPW3000-12A-X (for HUAWEI RH5885 V2 02310KEU Servers)

HUAWEI EPW3000-12A-X Server Power Supply rear view with power input and handle

Gambar 1: Tukangeun view of the EPW3000-12A-X Server Power Supply, showing the AC power input and extraction handle.

1. Produk Langkungview

The HUAWEI EPW3000-12A-X is a high-performance server power supply unit (PSU) designed for use with HUAWEI RH5885 V2 02310KEU servers. This non-modular power supply features active PFC and is equipped with a single fan for cooling. It provides stable and efficient power delivery essential for critical server operations.

2. Spésifikasi

Fitur Spésifikasi
Nomer modél EPW3000-12A-X
Aplikasi Server (HUAWEI RH5885 V2)
Jenis PFC Aktif
Pameget 1
Modular Non-Modular
Tipe panganteur 20 + 4Pin
CPU Power Panyambung 4 pinna
Graphics Card 12V Pin Number 8 pin + 2 x 6 pin
Jumlah palabuhan SATA 3
D-type Bus Number 3
80 PLUS sertifikasi Other Certification
Sertifikasi CE
Asalna Daratan Cina

2.1 Ratings kakuatan

HUAWEI EPW3000-12A-X Server Power Supply label with detailed power ratings

Figure 2: Product label showing detailed power input and output specifications.

Parameter Nilai
Masukan Voltage Rentang 1 220 - 240 V AC; 50/60 Hz; 16 A
Masukan Voltage Rentang 2 200 - 220 V AC; 50/60 Hz; 16 A
Masukan Voltage Rentang 3 100 - 130 V AC; 50/60 Hz; 16 A
Kaluaran 1 12.3 V; 243.9 A
Kaluaran 2 12.3 V; 203.3 A
Kaluaran 3 12.3 V; 97.6 A

3. Setup jeung Instalasi

This power supply is designed for hot-swappable installation in compatible HUAWEI RH5885 V2 servers. Always ensure the server is powered off and disconnected from the main power source before attempting installation or removal.

  1. Persiapan: Ensure the server chassis is compatible with the EPW3000-12A-X power supply. Verify that the server is powered down and all power cables are unplugged from the wall outlet.
  2. Locate PSU Bay: Identify the power supply bay in your HUAWEI RH5885 V2 server.
  3. Insert PSU: Grasp the power supply by its handle. Align the power supply with the empty bay and gently slide it in until it clicks securely into place. Ensure the connector pins at the front of the PSU engage properly with the server's backplane.
  4. Sambungkeun Kakuatan: Connect the appropriate AC power cable to the power input port on the rear of the power supply.
  5. Daya Hurung: Reconnect the server's main power cables to the wall outlet and power on the server. The power supply's status indicator (if present) should show normal operation.
HUAWEI EPW3000-12A-X Server Power Supply front view kalayan pin konektor

Gambar 3: Hareupeun view of the EPW3000-12A-X Server Power Supply, showing the connector pins for server integration.

4. Parentah Operasi

Once properly installed and connected, the EPW3000-12A-X power supply operates automatically to provide power to your server. It is designed for continuous operation within specified environmental conditions.

  • Operasi otomatis: The power supply will automatically regulate voltage and current to meet the server's power demands.
  • Cooling: The integrated fan provides necessary cooling for the power supply. Ensure adequate airflow around the server to prevent overheating.
  • Indikator Status: Refer to your server's documentation for information on power supply status indicators (LEDs) which typically show power presence, fault conditions, or normal operation.

5. Pangropéa

Regular maintenance helps ensure the longevity and reliable operation of your power supply.

  • beberesih: Periodically inspect the power supply's fan and vents for dust accumulation. Use compressed air to gently clean dust from the fan and ventilation openings. Ensure the server is powered off and unplugged before cleaning.
  • Tiupan hawa: Ensure that the server and its power supply have unobstructed airflow. Do not block ventilation openings.
  • Kaayaan Lingkungan: Operate the server within the recommended temperature and humidity ranges specified by the server manufacturer to prevent stress on the power supply.

6. Cara ngungkulan

If you encounter issues with your power supply, perform the following basic checks:

  • Henteu aya kakuatan:
    • Verify that the AC power cable is securely connected to both the power supply and a working wall outlet.
    • Pariksa stop kontak listrik ku alat sejen pikeun mastikeun eta fungsi.
    • Ensure the power supply is fully seated in its bay within the server chassis.
  • Daya Intermittent:
    • Check all power connections for looseness.
    • Ensure the server is not overloaded beyond the power supply's capacity.
  • Sora/Bau Anu Ahéng:
    • Immediately power off the server and disconnect it from the power source. Do not attempt to operate the power supply. Contact technical support.

For more complex issues, consult your server's service manual or contact qualified technical personnel.

7. Garansi jeung Rojongan

This product is supplied by MLLSE. Please note the following regarding warranty and support:

  • Cakupan Garansi: Warranty is provided for functional problems.
  • Warranty Invalidation: The warranty will be void if the product is refitted or disassembled without permission, or if the warranty label is damaged.
  • Kaayaan produk: The item may be used or refurbished. While efforts are made to provide the best possible unit, minor surface scratches may be present and do not affect functionality.
  • Damage Upon Receipt: If damage is found upon receipt, a complete proof of damage (including an unboxing video and documentation from the logistics company) must be provided to be eligible for compensation. Without such proof, compensation may not be possible.

For technical assistance or warranty claims, please contact your vendor or the MLLSE support channel.

8. Tips pamaké

  • Always ensure the server is completely powered off and unplugged before installing or removing the power supply to prevent electrical hazards and damage to components.
  • When handling the power supply, use the designated handle to ensure a firm grip and proper alignment during installation.
  • Regularly check the server's event logs for any power-related warnings or errors, which can indicate potential issues with the power supply before they become critical.

Dokumén Patali - EPW3000-12A-X

Praview Pituduh Pangguna Server Cloud Elastis - HUAWEI CLOUD
Pituduh lengkep pikeun Elastic Cloud Server (ECS) HUAWEI CLOUD, anu ngawengku pameseranasing, konfigurasi, manajemen, jaringan, kaamanan, sareng fitur-fitur canggih pikeun palaksanaan server awan anu efisien.
Praview Huawei Elastic Cloud Server (ECS) User Guide
This comprehensive user guide provides detailed instructions and best practices for managing Huawei Cloud Elastic Cloud Servers (ECS), covering topics from instance creation and billing to security, networking, and monitoring.
Praview Réferénsi API Server Awan Huawei Elastic
Pituduh rujukan API anu lengkep pikeun Huawei Elastic Cloud Server (ECS), anu ngajelaskeun operasi, parameter, sarengamppikeun ngatur sumber daya komputasi awan, kalebet OpenStack Nova API.
Praview Huawei Server Migration Service FAQs: Comprehensive Guide
Explore Huawei's Server Migration Service (SMS) with this detailed FAQ. Find answers on product features, OS compatibility, network setup, agent installation, migration troubleshooting, and best practices for migrating servers to HUAWEI CLOUD.
Praview Sarat sareng Kaayaan Produk Perawatan HUAWEI
Dokumén ieu ngagariskeun syarat sareng kaayaan pikeun jasa HUAWEI Care, kalebet Garansi Perpanjangan, Perlindungan Layar, Perlindungan Karusakan Teu Kahaja pikeun arloji, sareng Perawatan Karugian pikeun earbuds. Éta rinci ngeunaan liputan, pangaluaran, aktivasina, pembatalan, sareng produk anu lumaku dina sagala rupa kategori alat HUAWEI sapertos smartphone, tablet, laptop, sareng anu tiasa dianggo.
Praview Huawei Tecal RH2288H V2 Server Compatibility List
This document provides a comprehensive list of operating systems, virtualization software, CPUs, and other components compatible with the Huawei Tecal RH2288H V2 server. It details supported versions, part numbers, and relevant certifications.