1. Produk Langkungview
This document provides instructions for the installation, operation, maintenance, and troubleshooting of the replacement humidity sensor compatible with DEYE Dehumidifier models DY-612S and 25A3. This sensor is a critical component for accurate humidity detection, ensuring your dehumidifier operates efficiently.

2. Setup jeung Instalasi
Kasalametan munggaran: Always disconnect the dehumidifier from the power supply before attempting any installation or maintenance.
- Nyiapkeun Dehumidifier: Ensure the dehumidifier is unplugged and completely powered off. Allow it to cool down if it has been recently operating.
- Access the Sensor Compartment: Carefully open the dehumidifier casing to locate the existing humidity sensor. Refer to your dehumidifier's specific service manual for exact instructions on accessing internal components.
- Pegatkeun sambungan sénsor heubeul: Gently disconnect the wiring harness from the old humidity sensor. Note the orientation and connection points if possible.
- Cabut Sénsor Lama: Unmount the old sensor from its position. It may be held by clips, screws, or adhesive.
- Pasang Sénsor Anyar: Mount the new DEYE humidity sensor (KB-5150) in the same location and orientation as the old one. Ensure it is securely fastened.
- Sambungkeun Sensor Anyar: Connect the wiring harness to the CN2 connector on the new sensor module. Ensure the connection is firm and correctly oriented.
- Pasang deui sareng Uji: Carefully reassemble the dehumidifier casing. Plug the dehumidifier back into the power supply and turn it on. Monitor its operation to ensure the humidity readings are accurate and the unit functions as expected.
3. Parentah Operasi
The humidity sensor is an automatic component that works in conjunction with your DEYE dehumidifier's control system. It continuously measures the ambient humidity and sends this data to the dehumidifier's main board.
- Once installed, the sensor operates automatically when the dehumidifier is powered on.
- There are no direct user controls for the sensor itself. Its function is integrated into the dehumidifier's overall operation.
- Ensure the dehumidifier's air intake and exhaust vents are unobstructed for accurate humidity readings.
4. Pangropéa
The humidity sensor requires minimal maintenance. To ensure its longevity and accurate performance:
- Tetep Bersih: Periodically, when performing general dehumidifier maintenance (e.g., cleaning filters), you may gently clean the sensor area. Use a soft, dry brush or compressed air to remove any dust or debris that might accumulate on the sensor element. Do not use liquids or abrasive cleaners.
- Hindarkeun Karusakan Fisik: Handle the sensor with care during installation and any subsequent maintenance. Avoid bending the PCB or applying excessive force to the sensor element.
- Kaayaan Lingkungan: Ensure the dehumidifier operates within its specified environmental conditions to prevent premature sensor degradation.
5. Cara ngungkulan
If your DEYE dehumidifier is exhibiting issues related to humidity detection after sensor replacement, consider the following troubleshooting steps:
| Gejala | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Dehumidifier displays incorrect humidity readings (e.g., always high/low, fluctuating wildly). | Faulty sensor, loose connection, or obstruction. | 1. Power off and unplug the dehumidifier. 2. Re-check the sensor's connection (CN2) to ensure it is secure. 3. Inspect the sensor element for any visible damage or heavy dust accumulation. Clean if necessary. 4. If issues persist, the sensor may be faulty and require replacement. |
| Dehumidifier does not respond to humidity changes. | Sensor not communicating with the main board. | 1. Verify the sensor is correctly installed and connected. 2. Ensure no wires are pinched or damaged. 3. If the problem continues, consult a qualified technician as the issue might be with the dehumidifier's main control board rather than the sensor itself. |
| Dehumidifier displays a specific error code related to humidity. | Karusakan sensor atanapi kasalahan komunikasi. | Refer to your DEYE dehumidifier's user manual for the meaning of specific error codes. Often, humidity-related error codes point to a sensor issue. Follow the steps for incorrect readings. |
6. Spésifikasi
- Jenis produk: Kalembaban Sensor Module
- Kasaluyuan: DEYE Dehumidifier models DY-612S, 25A3
- Modél modul: KB-5150
- PCB Markings: Deye 94V-0, TR1, CN2
- Asal: Daratan Cina
- Perkiraan Beurat Pakét: 0.1 kg (The sensor module itself is very lightweight)
- Perkiraan Ukuran Paket: 10 cm (Panjang) x 10 cm (Lebar) x 10 cm (Jangkungna)
7. Garansi jeung Rojongan
For specific warranty information regarding this humidity sensor, please refer to the terms and conditions provided by your original seller or the manufacturer. Typically, replacement parts may carry a limited warranty against manufacturing defects.
For technical support or further assistance with your DEYE dehumidifier, please contact DEYE customer service or a certified appliance technician.
8. Tips pamaké
No specific user tips were available from the provided data. However, general advice for humidity sensors includes:
- Always ensure the sensor is installed in a location within the dehumidifier where it can accurately sample the ambient air without being directly exposed to moisture or airflow from the fan.
- If your dehumidifier has a calibration function for humidity, consider performing it after replacing the sensor to ensure optimal accuracy.
- Regularly clean your dehumidifier's air filter to maintain good airflow, which indirectly helps the humidity sensor function correctly.