1. Bubuka
The FG-200 DDS Function Signal Generator is a compact and versatile device designed for generating a wide array of waveforms. It is an essential tool for electronic circuit testing, debugging, frequency characteristic analysis, and pulse response testing of audio amplifiers. With its high accuracy and frequency stability, it is also well-suited for calibrating oscilloscope scanning time factors.

2. Fitur konci
- Supports 15 distinct waveform outputs: Sine, Square, Triangular, Forward Sawtooth, Reverse Sawtooth, Half-wave, Full-wave, Schumann wave, Noise waveform, Electrocardiogram (ECG), Exponential Rise, Exponential Decrease, Lorentz Pulse, Gaussian Pulse, and Sinc Pulse.
- Fully functional and user-friendly interface.
- Compact and portable design (125 x 80 x 26.5mm).
- Equipped with a save function to retain all configured parameters.
- kaluaran adjustable amplitude (up to ±10V P-P) and DC offset (up to 10V).
- Integrated switchable filter for optimizing sine and pulse waveform outputs.
- High accuracy and frequency stability, ideal for oscilloscope calibration.
3. Spésifikasi Téknis
| Parameter | Nilai |
|---|---|
| Bentuk Gelombang Kaluaran | 15 types (Sine, Square, Triangle, Sawtooth, Resawtooth, ECG, EXP rise, EXP decay, Lorenz, Gaussian, Sinc, Half wave, Full wave, Schumann, Noise) |
| Sasayogian tanaga | DC 4-9V (DC5V recommended), 3.5mm DC interface |
| Konsumsi Ayeuna | 180mA di 5V |
| Frequency Range (Sine Wave) | 0.01Hz - 500kHz |
| Frequency Range (Other Waveforms) | 0.01Hz - 100kHz (can be extended with reduced distortion requirements) |
| Resolusi Frékuénsi | 0.01Hz |
| Distorsi Gelombang Sinus | <1% below 1kHz, <0.5% above 1kHz |
| Kaluaran Amplituit | Max ±10V (Peak-to-Peak) |
| Impedansi kaluaran | 50 Ω |
| DC Offset | Max 10V (with shutdown function) |
| Diménsi | 125.8mm x 80.5mm x 26.6mm (kira-kira 4.95 inci x 3.17 inci x 1.05 inci) |

4. Eusi Paket
The FG-200 DDS Function Signal Generator is available in two package options:
Pakét 1:
- FG-200 Host Unit (1)
- USB Power Cord (1)
- BNC Clamp Kawat (1)
Pakét 2:
- FG-200 Host Unit (1)
- USB Power Cord (1)
- BNC Clamp Kawat (1)
- Double-ended BNC Cable (1)
- Schumann Wave Module Board (1)



5. Parentah Setup
- Sambungan Daya: Connect the provided USB to 3.5mm cable to the power input port of the FG-200. For power, use a computer USB interface, a mobile phone charging head, or a power bank. It is highly recommended to use a power source that has passed 3C certification to prevent potential signal generator malfunctions due to poor power supply.
- Sambungan Kaluaran: Connect the BNC clamp wire to the DDS OUT port on the generator.
- Sambungkeun cl beureumamp wire to the oscilloscope probe.
- Nyambungkeun cl hideungamp wire to the oscilloscope GND clamp.


6. Parentah Operasi
6.1. General Operation Flow
- Daya Hurung: Press the POWER switch to turn on the device.
- Select Waveform: Pencét éta
MODEkey to cycle through and select the desired output waveform. - Saluyukeun Frékuénsi: Ngagunakeun éta
CURSORkey to move the cursor to the frequency digits. Then, use the+jeung-keys to adjust the frequency value. - Saluyukeun Ampliteratur: Puterkeun
AMPknob clockwise to increase the signal amplituit. - Adjust DC Offset:
- Pencét éta
DC OFFSETpindah kaON. - Use the yellow knob to adjust the DC component of the signal.
- To remove DC offset, press the
DC OFFSETpindah kaOFF.
- Pencét éta
- Apply Filter: For sine waves of 300KHz or larger, press the
FILTERbutton to clarify the waveform. Note that this may slightly decrease the signal amplituit. - Start/Stop Output: Pencét éta
RUN/STOPbutton to start or stop the waveform output. When the cursor is not flashing, the waveform is being output, and other keys are inactive. To adjust parameters, pressRUN/STOPfirst to make the cursor flash. - Simpen Setélan: All setting parameters are automatically saved.
6.2. Waveform Types
The FG-200 supports the following 15 waveform types:
| Waveform Name | Katerangan |
|---|---|
| DOSA | Sinusoidal waveform |
| pasagi | Square waveform |
| segitiga | Bentuk gelombang segitiga |
| Sawtooth | Forward sawtooth wave |
| Resawtooth | Anti-sawtooth waveform |
| EKG | Electrocardiogram waveform |
| EXP rise | Exponential rise waveform |
| EXP decay | Exponential decrease waveform |
| Lorenzo | Lorenz pulse |
| Gaussian | Gaussian pulsa |
| Sinc | Sinc pulse |
| Satengah gelombang | Half-wave rectified waveform |
| Gelombang pinuh | Full-wave rectified waveform |
| Schumann | Schumann wave |
| Geuning | Noise waveform |



7. Pangropéa
- Jaga alat tetep beresih sareng leupas tina lebu. Anggo kaén anu lemes sareng garing pikeun beberesih.
- Hindarkeun alat ka suhu ekstrim, kalembaban, atanapi sinar panonpoé langsung.
- Ulah make cleaners abrasive atawa pangleyur.
- Simpen alat dina tempat anu aman nalika henteu dianggo pikeun nyegah karusakan fisik.
8. Cara ngungkulan
- Henteu aya Kaluaran Sinyal:
- Ensure the power supply is connected correctly and is a stable DC 4-9V (preferably 5V) source. Poor power supply can cause malfunction.
- Verify that the BNC clamp wire is securely connected to the "DDS OUT" port and to the oscilloscope probe/GND.
- Pariksa lamun éta
RUN/STOPbutton is in the "RUN" state (cursor not flashing). - Confirm that a waveform type has been selected using the
MODEkonci.
- Distorted or Unclear Waveform:
- For sine waves of 300KHz or higher, try pressing the
FILTERbutton to clarify the waveform. - Pastikeun catu daya stabil sareng cekap.
- Check the oscilloscope settings (e.g., vertical scale, time base) to ensure they are appropriate for the signal being generated.
- For sine waves of 300KHz or higher, try pressing the
- Cannot Adjust Parameters:
- Pencét éta
RUN/STOPbutton. The cursor on the display should flash, indicating that parameters can now be adjusted.
- Pencét éta
9. Tips pamaké
- For optimal performance and to avoid signal noise, always use a high-quality, stable 5V power adapter, preferably one that is 3C certified.
- When working with higher frequencies, especially sine waves above 300KHz, remember to engage the
FILTERfunction for a cleaner output, keeping in mind a slight amplitude reduction may occur. - The device automatically saves your last settings, making it convenient for repeated experiments or measurements.
- The square wave output is particularly useful for calibrating oscilloscope attenuators and probes due to its sharp transitions.
10. Garansi jeung Rojongan
Kanggo inpormasi garansi, dukungan téknis, atanapi patarosan jasa, mangga ngahubungi pangecér atanapi produsén langsung. Simpen resi pameseran anjeun salaku bukti pameseran.