Hi-Link HLK-5M Series

Hi-Link Logo

HLK-5M Series AC/DC Power Supply Module User Manual

Models: HLK-5M03, HLK-5M05, HLK-5M09, HLK-5M12, HLK-5M15, HLK-5M24

1. Bubuka

The Hi-Link HLK-5M series module power supply is a compact, high-efficiency AC/DC power module designed for various applications. It features a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. These modules are widely used in smart home devices, automation control systems, communications equipment, instrumentation, and other industrial applications.

Hi-Link 5W AC/DC Power Module series overview

Gambar 1: Leuwihview of Hi-Link HLK-5M Series Modules

2. Fitur Produk

  • Ultra-thin, ultra-small, compact volume.
  • Global universal input voltage range: 85~265Vac.
  • Low power consumption, environmentally friendly, no-load loss <0.1W.
  • Low ripple and low noise output.
  • High output short circuit and over-current protection with automatic self-recovery.
  • High efficiency and high power density.
  • Input and output isolation voltage: 3000Vac.
  • 100% full load aging and testing for reliability.
  • High reliability, long life design, with continuous working time greater than 100,000 hours.
  • Meets UL and CE requirements; product design adheres to EMC and safety testing standards.
  • Constructed with high-quality environmentally friendly waterproof plastic potting, providing moisture, vibration, water, and dust resistance to meet IP65 standards.
  • Cost-effective solution.
  • Designed to work without external circuitry.
  • Includes a 1-year quality guarantee period.

3. Spésifikasi

3.1. Model Specifications

The HLK-5M series offers various output voltage options while maintaining a consistent size and pin configuration.

Table of Model, Output Power, Output Voltage, Output Current for HLK-5M series

Figure 2: HLK-5M Series Model Specifications

3.2. Kaayaan Lingkungan

The modules are designed to operate reliably across a range of environmental conditions.

Table of Environmental Conditions (Working temp, Storage temp, Humidity, etc.)

Figure 3: Environmental Conditions for HLK-5M Series

3.3. Output Features (Example: 15V/333mA Model)

Detailed output characteristics for a typical model (HLK-5M15).

Table of Output Features for 15V/333mA model

Figure 4: Output Features for HLK-5M15 (15V/333mA)

3.4. Input Voltage and Load Characteristics

Graphs illustrating the module's performance under varying input voltage jeung kaayaan beban.

Graph: Input voltage and load characteristic curve

Figure 5: Input Voltage and Load Characteristic Curve

3.5. Working Environment Temperature and Load Characteristics

Graph showing the relationship between ambient temperature and maximum permissible load.

Graph: Working environment temperature and load characteristics

Figure 6: Working Environment Temperature and Load Characteristics

3.6. Dimensi jeung Beurat

The physical dimensions and pinout of the HLK-5M series modules.

Diagram: Dimensions and pinout of the module

Figure 7: Module Dimensions (Unit: mm) and Pinout (Top View)

4. Setélan

The HLK-5M series modules are designed for easy integration into various circuits. They operate without the need for external components in typical applications.

4.1. Typical Application Circuit

A recommended circuit for integrating the power module. The input design incorporates a UL listed 1A / 250Vac slow-blow fuse or a 10Ω wire-wound resistor for protection. The PCB board is made of double-sided copper clad foil with a 94-V0 fire resistance grade.

Wiring Diagram: Typical application circuit

Figure 8: Typical Application Circuit Diagram

4.2. Pin Pedaran

  • AC (Pins 1 & 2): AC input terminals (85-265Vac).
  • -Vo (Pin 3): kaluaran négatip voltage terminal.
  • +Vo (Pin 4): Kaluaran positif voltage terminal.

Ensure correct polarity and secure connections when integrating the module into your system.

5. Parentah Operasi

The HLK-5M series modules are designed for straightforward operation once correctly installed.

  • Masukan Voltage: Connect the module to an AC power source within the universal input voltage range of 85-265Vac.
  • Kaluaran Voltage: The module will provide a stable DC output voltage (3.3V, 5V, 9V, 12V, 15V, or 24V depending on the model) at the +Vo and -Vo terminals.
  • Sambungan beban: Connect your load to the output terminals, ensuring that the total current draw does not exceed the rated output current for your specific module model (refer to Section 3.1).
  • Kasalametan: Always ensure proper insulation and avoid touching live terminals during operation. The module provides 3000Vac input/output isolation for safety.

6. Pangropéa

The HLK-5M series power modules are designed for long-term, maintenance-free operation due to their robust construction and IP65 rating.

  • beberesih: If necessary, gently wipe the module's exterior with a dry, soft cloth. Avoid using liquids or abrasive cleaners.
  • Lingkungan: Ensure the module is operated within the specified environmental conditions (temperature, humidity, atmospheric pressure) as detailed in Section 3.2.
  • Cooling: The module uses natural cooling. Ensure adequate airflow around the module, especially when operating at higher loads or temperatures, to prevent overheating.
  • Pamariksaan: Periodically inspect the module and its connections for any signs of damage, loose wiring, or discoloration.

7. Cara ngungkulan

Bagian ieu nyadiakeun léngkah ngungkulan dasar pikeun masalah umum.

  • Taya Kaluaran Voltage:
    • Pariksa yén input AC voltage is within the specified range (85-265Vac) and is correctly connected.
    • Check the input fuse or resistor in the application circuit (refer to Section 4.1).
    • Ensure the load is not drawing excessive current, which might trigger the over-current protection. The module features self-recovery after over-current conditions are removed.
    • Confirm that the output connections are secure and correctly polarized.
  • Volum Kaluaran Teu Stabiltage:
    • Check for loose connections at both input and output terminals.
    • Ensure the load is stable and not fluctuating rapidly.
    • Verify that the ambient temperature is within the operating range and that the module has sufficient natural cooling.
  • Overheating:
    • Reduce the load if it is close to the maximum rated current.
    • Improve ventilation around the module.
    • Ensure the ambient temperature is not exceeding the maximum working temperature.

8. Tips pamaké

  • When designing your circuit, always consider the maximum output current and power for your chosen module model to ensure stable and reliable operation.
  • For optimal performance and longevity, operate the module well within its specified temperature and load limits.
  • Although the module is potted for environmental protection, avoid direct exposure to harsh chemicals or prolonged submersion.

9. Garansi jeung Rojongan

The Hi-Link HLK-5M series power supply modules come with a 1-year quality guarantee period from the date of purchase.

For technical support, inquiries, or warranty claims, please contact Shenzhen Hi-Link Electronic Co., Ltd. directly:

Please provide your product model and a detailed description of the issue when contacting support to facilitate a quicker resolution.

Dokumén Patali - HLK-5M Series

Praview HLK-TX510-028S Face Recognition Module Mini App User Manual
User manual for the Shenzhen Hi-Link Electronic Co., Ltd. HLK-TX510-028S Face Recognition Module, detailing setup, hardware connections, and usage of the WeChat mini app for device configuration and feature management.
Praview Buku Panduan Pamaké Shenzhen Hi-Link HLK-B30: 802.11n+BLE 4.2 Modul Wireless
Manual pamaké komprehensif pikeun Shenzhen Hi-Link HLK-B30, modul nirkabel konsumsi-rendah nampilkeun Wi-Fi 802.11n sareng Bluetooth 4.2. Nyertakeun pedaran produk, spésifikasi téknis, rinci hardware, wewengkon aplikasi, sarta prosedur nguji.
Praview HLK-A S-1WR3 & HLK-B LS-1WR3 1W Isolated DC/DC Power Module Datasheet
Datasheet for Hi-link's HLK-A S-1WR3 and HLK-B LS-1WR3 series of 1W, constant voltage input, isolated and unregulated single/dual output DC/DC power modules. Features include high efficiency, wide operating temperature, short circuit protection, and small SIP package. Suitable for various electronic applications requiring isolated power. Includes detailed specifications, application circuits, and considerations.
Praview Shenzhen Hi-Patalina HLK-LD2451 Kendaraan Status Deteksi Modul Manual Pamaké
Manual pamaké pikeun Shenzhen Hi-Link HLK-LD2451, sensitipitas tinggi 24 GHz status wahana modul sensing. Rincian pedaran produk, ciri, aplikasi, hardware, pamakéan, konfigurasi, kinerja, jeung rojongan teknis.
Praview HLK-LD2451 Protokol Komunikasi Serial
This document details the serial communication protocol for the Hi-Link HLK-LD2451 radar module, essential for secondary development. It covers command structures, data output formats, and configuration methods via TTL serial interface.
Praview HLK-B20 BLE 4.2 Wireless Module User Manual
This user manual provides comprehensive information on the Hi-Link HLK-B20, a low-consumption Bluetooth BLE 4.2 wireless control module. It covers product description, technical specifications, hardware details, pin functions, configuration methods, AT commands, and testing procedures.