1. Bubuka
The SINOTIMER MT-M Digital PID Temperature Controller is a versatile instrument designed for precise temperature regulation in both heating and cooling applications. It features a clear digital display, multiple control modes including PID and ON/OFF, and supports various thermocouple inputs. This manual provides essential information for the safe and effective installation, operation, and maintenance of your temperature controller.

2. Setélan
2.1 Instalasi fisik
The MT-M model has a panel size of 72 x 72mm and requires an installation hole size of 68 x 68mm. Ensure the mounting location is free from excessive vibration, moisture, and corrosive gases. The controller is made of plastic.

2.2 Wiring jeung sambungan
Proper wiring is crucial for the safe and correct operation of the temperature controller. Refer to the diagram below for output and input connections. Always ensure power is disconnected before performing any wiring.

Métode kaluaran:
- Relay Output (RELAY): Can be directly connected to a heat pipe or to an AC contactor. The contact capacity is 3A at 250VAC (resistive load).
- Solid State Output (SSR): Connects to an external Solid State Relay. This provides a 12VDC voltage impulse output to control a DC-controlled AC solid state relay.
Métode Input:
- The controller accepts thermocouple inputs with index numbers K, E, J, or N. Ensure the correct thermocouple type is selected in the controller's settings to match your sensor.
3. Parentah Operasi
3.1 Panel Overview
The front panel features a dual-line digital display and control buttons:
| Label | Fungsi |
|---|---|
| PV | Measured Value / Various Parameter Symbols |
| SV | Set Value / Various Parameter Set Values |
| KALUAR | Output Indicator Lamp (illuminates when output is active) |
| AT | PID Automatic Tuning Indicator Lamp |
| AL1 | Alarm Indicator Lamp (illuminates when alarm condition is met) |
| ▲ | Increase numbers / Scroll up |
| ▼ | Decrease numbers / Scroll down |
| ◀ | Shift Key (moves cursor for digit selection) |
| MODÉ | Used for parameter calling up and set value registration |
3.2 Operasi Dasar
- Daya Hurung: Connect the controller to an AC100-240V 50/60HZ power supply. The display will light up, showing the current measured temperature (PV) and the set temperature (SV).
- Setting Temperature (SV): Ngagunakeun éta ▲ jeung ▼ buttons to adjust the Set Value (SV). Use the ◀ key to shift between digits for faster adjustment. Press MODÉ to confirm the new SV.
- Modeu kontrol: The controller supports PID and ON/OFF control. ON/OFF control is active when the P (proportional band) parameter is set to 0. Refer to the full manual for advanced PID tuning parameters.
- Fungsi Alarm: The controller has one alarm with 6 modes: high deviation, low deviation, and process value alarm. Configure alarm parameters as needed for your application.
- Unit Suhu: The display can show temperature in Celsius (℃) or Fahrenheit (°F). This setting can be changed by the user.
4. Pangropéa
To ensure the longevity and accurate performance of your SINOTIMER MT-M controller, follow these maintenance guidelines:
- beberesih: Keep the controller's display and buttons clean. Use a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Kaayaan Lingkungan: Operate the controller within the specified ambient temperature range of 0-50°C and humidity of 30-85% RH (non-condensing). Avoid exposure to corrosive gases, excessive dust, or direct sunlight.
- Sambungan: Périodik pariksa sagala sambungan wiring pikeun mastikeun aranjeunna aman tur bebas tina korosi.
5. Cara ngungkulan
If you encounter issues with your temperature controller, consider the following general troubleshooting steps:
- Henteu aya kakuatan: Pariksa sambungan catu daya sareng pastikeun voltasenatage is within the AC100-240V range.
- Bacaan Suhu Lepat: Verify that the thermocouple is correctly connected and that the input type selected in the controller matches your thermocouple (K, E, J, or N). Ensure the thermocouple is properly inserted into the process.
- Kaluaran Teu Aktipkeun: Check the set temperature (SV) against the measured temperature (PV). Ensure the control mode (PID/ON-OFF) and associated parameters are correctly configured. Verify external relay or SSR connections.
- Alarm Issues: Review the alarm settings and ensure they are configured as desired. Check if the alarm condition is met.
For more complex issues, consult the full product manual or contact customer support.
6. Spésifikasi
| Fitur | Spésifikasi |
|---|---|
| Modél | MT-M |
| Sasayogian tanaga | AC100-240V 50/60HZ |
| Suhu Setting Range | -50 ~ +999 ℃/°F |
| Input Thermocouple | K, J, E, N types (user selectable) |
| tampilan | Two lines, three digits (PV, SV) in Celsius or Fahrenheit |
| Resolusi tampilan | 1°C / 1°F |
| Kontrol Precision | ± 0.5%FS |
| Modeu Kontrol | PID, ON/OFF (On/Off Control when P=0) |
| Kaluaran | One group control output: Relay contacts 3A @250VAC OR Voltage impulse output 12VDC for external SSR |
| Alarem | One alarm, 6 kinds of alarm modes (high deviation, low deviation, process value alarm) |
| Konsumsi Daya | 10VA |
| Suhu Ambient | 0-50°C |
| Kalembaban Ambient | 30-85% RH (no corrosive gas) |
| Item Size (MT-M) | 72 x 72 mm |
| Installation Hole Size (MT-M) | 68 x 68 mm |
| Bahan | palastik |
7. Tips pamaké
- Panempatan sénsor: For accurate temperature control, ensure your thermocouple is placed in a location that accurately represents the temperature of the process you are controlling, away from direct drafts or heat sources that are not part of the process.
- Pangaturan PID: While the controller offers PID auto-tuning, manual fine-tuning may be necessary for optimal performance in specific applications. Experiment with P, I, and D parameters to achieve stable and precise control without overshoot or oscillation.
- Output Type Selection: Carefully choose between Relay and SSR output based on your application's power requirements and switching frequency. SSRs are generally preferred for faster switching and longer lifespan in high-frequency applications.
8. Jaminan & Dukungan
For warranty information, technical support, or service inquiries, please refer to the documentation provided with your purchase or contact your retailer. Keep your purchase receipt as proof of purchase.